CoChat

The biomechanics of the human patella during passive knee flexion

Open access
Heegaard, J., Leyvraz, P.F., Curnier, A., Rakotomanana, L., Huiskes, R. · 1995 · Journal of Biomechanics
Cited by 227

The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.

Abstract

The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.

Overview

Integrity signals

Registry

Crossref · 10.1016/0021-9290(95)00059-q

Cites

75 of 75 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 75 references

Research works printed but not linked: 4

  1. Bandi, 1970, Chondromallacia Patellae und Femoro-Patellare Arthrose, Helv. Chir. Acta, 11, 1
  2. Muller, 1980, Etude photoelasticimétrique tridimensionnelle de la patella (rotule). Méthodologie et premiers résultats, Bull. Assoc. Anat., 89
  3. Shoji, 1974, A study of the patello-femoral contact zones in human knees, J. Jap. orthop. Ass., 48, 85
  4. Truesdell, 1977, Vol. 1

Cited by

Items 201–227 of 227

Metadata

Authors
Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
1995-11
Volume
28
Issue
11
Pages
1265-1279
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2166361133
Cited by
180
References
76
FWCI
5.39
Type
journal article
Language
en
Open access
green
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.