The biomechanics of the human patella during passive knee flexion
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PFPS can be diagnosed and treated more effectively if normal patellar tracking is known.”
From Patellar Tracking during the Gait Cycle (2011) · cites this paper as [5]
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
An Introduction to Continuum Mechanics
Gurtin, M. E., & Drugan, W. J. (1984) · Journal of Applied Mechanics · doi:10.1115/1.3167763 · Cited by 1,704
An Introduction to Continuum Mechanics
(1981) · Mathematics in Science and Engineering/Mathematics in science and engineering · doi:10.1016/s0076-5392(08)x6102-8 · Cited by 1,508
A first course in rational continuum mechanics
Truesdell, C. A. (1976) · Cited by 1,031
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Huberti, H. H., & Hayes, W. C. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00010 · Cited by 840
A mixed formulation for frictional contact problems prone to Newton like solution methods
Alart, P., & Curnier, A. (1991) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(91)90022-x · Cited by 758
Self-citationRoentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
A finite element method for a class of contact-impact problems
Hughes, T. J. R., Taylor, R. L., III, Sackman, J. L., Curnier, A., & Kanok‐Nukulchai, W. (1976) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(76)90018-9 · Cited by 597
Self-citationA survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539 · cited 1×
“A general description of this method, its principles, its possibilities and limitations in orthopedic biomechanics has been published by Huiskes and Chao (1983).”
MethodSelf-citation
Research works printed but not linked: 4
- Bandi, 1970, Chondromallacia Patellae und Femoro-Patellare Arthrose, Helv. Chir. Acta, 11, 1
- Muller, 1980, Etude photoelasticimétrique tridimensionnelle de la patella (rotule). Méthodologie et premiers résultats, Bull. Assoc. Anat., 89
- Shoji, 1974, A study of the patello-femoral contact zones in human knees, J. Jap. orthop. Ass., 48, 85
- Truesdell, 1977, Vol. 1
Cited by
Items 101–200 of 227
Posterior Capsulotomy of the Knee: Treatment of Minimal Knee Extension Deficit
Gomes, J. L. E., Leie, M. A., Soares, A. D. F., Ferrari, M. B., & Sánchez, G. (2017) · Arthroscopy Techniques · doi:10.1016/j.eats.2017.06.033 · Cited by 18
Elias, J. J., & Saranathan, A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4024287 · Cited by 18
Dynamic simulation of tibial tuberosity realignment: model evaluation
Purevsuren, T., Elias, J. J., Kim, K., & Kim, Y. H. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.936857 · Cited by 16
Horng, A., Raya, J. G., Zscharn, M., König, L., Notohamiprodjo, M., Pietschmann, M. F., Hoehne-Hückstädt, U., Hermanns, I., Glitsch, U., Ellegast, R. P., et al. (2010) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0029-1245790 · Cited by 16
Simulación en 3D con elementos finitos de un modelo de prótesis de rodilla
García, B. S., Banzo, J. C., Aznar, J. M. G., Castellano, M. D., & Iñigo, F. S. (2003) · Revista Española de Cirugía Ortopédica y Traumatología · doi:10.1016/s1888-4415(03)76072-x · Cited by 15
Innocenti, B., Bori, E., & Piccolo, S. (2020) · The Knee · doi:10.1016/j.knee.2019.09.007 · Cited by 14
Cohen, Z. A., McCarthy, D. M., Roglic, H., Henry, J. H., Rodkey, W. G., Steadman, J. R., Mow, V. C., & Ateshian, G. A. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056183 · Cited by 14
Use of a TTA Plate for Correction of Severe Patella Baja in a Chihuahua
Edwards, G. A., & Jackson, A. H. (2012) · Journal of the American Animal Hospital Association · doi:10.5326/jaaha-ms-5686 · Cited by 13
A Detailed and Validated Three Dimensional Dynamic Model of the Patellofemoral Joint
Akbar, M., Farahmand, F., Jafari, A., & Foumani, M. S. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006403 · Cited by 12
Site Dependence of Thickness and Speed of Sound in Articular Cartilage of Bovine Patella
Patil, S. G., Zheng, Y., & Chen, X. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.05.006 · Cited by 12
Pina, M., DeMiguel, D., Cobos, F. P., Marcé‐Nogué, J., & Moyà‐Solà, S. (2020) · Palaeontology · doi:10.1111/pala.12466 · Cited by 11
Makani, A., Shirazi-Adl, A., & Ghezelbash, F. (2022) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3646 · Cited by 11
Patellar Tracking during the Gait Cycle
Abbas, G., & Diss, C. (2011) · Journal of orthopaedic surgery · doi:10.1177/230949901101900305 · Cited by 9
Patellofemoral Dysfunction in Sports Trochleoplasty: Indications and Techniques
Ryzek, D.-F., & Schöttle, P. B. (2015) · The Journal of Knee Surgery · doi:10.1055/s-0034-1398374 · Cited by 9
Knorpelschaden des Kniegelenks und berufliche Belastung. Ergebnisse einer arthroskopischen Studie
Spahn, G., Peter, M. M., Hofmann, G., & Schiele, R. (2010) · Zeitschrift für Orthopädie und Unfallchirurgie · doi:10.1055/s-0029-1240974 · Cited by 9
Greimel, F., Maderbacher, G., Baier, C., Krieg, B., Zeman, F., Grifka, J. K., & Keshmiri, A. (2020) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-020-03578-1 · Cited by 9
Die Quadrizepsplastik nach Judet zur Therapie der myogenen Extensionskontraktur des Kniegelenks
Holschen, M., & Lobenhoffer, P. P. (2014) · Operative Orthopädie und Traumatologie · doi:10.1007/s00064-013-0286-8 · Cited by 9
A constrained‐optimization methodology for the detection phase in contact mechanics simulations
Aragón, A. M., Yastrebov, V. A., & Molinari, J. (2013) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.4561 · Cited by 9
Three-dimensional dynamic model of the knee
Kim, S. (1998) · KSME International Journal · doi:10.1007/bf02942578 · Cited by 8
Amiri, S., Wilson, D. R., Anglin, C., Houwelingen, A. P. V., & Masri, B. A. (2012) · The Journal of Arthroplasty · doi:10.1016/j.arth.2012.05.007 · Cited by 8
Pina, M. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 8
3-D Finite Element Method Modeling and Contact Pressure Analysis of the Total Knee Joint in Flexion
Zhang, X., Guo, Y., & Chen, W. (2009) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2009.5162138 · Cited by 7
Li, S., Tiwari, S. R., Chang, S., Du, S.-C., & Zhang, Y. (2023) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-023-03649-0 · Cited by 7
Finite Element Analysis of Knee Joint with Special Emphasis on Patellar Implant
Kumbhalkar, M. A., Rangari, D. T., Pawar, R., Phadtare, R. A., Raut, K. R., & Nagre, A. N. (2020) · Lecture notes in mechanical engineering · doi:10.1007/978-981-15-4488-0_29 · Cited by 7
In-vivo knee loading before and after ACL transection in an animal model
Hasler, E. M. (1996) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/16723 · Cited by 7
Repositioning the Knee Joint in Human Body FE Models Using a Graphics-Based Technique
Jani, D., Chawla, A., Mukherjee, S., Goyal, R., Vusirikala, N., & Jayaraman, S. K. (2012) · Traffic Injury Prevention · doi:10.1080/15389588.2012.664669 · Cited by 6
Bildgebende Untersuchungen des Patellofemoralgelenks
Kramer, J., Scheurecker, G., Scheurecker, A., Stöger, A., Huber, H., & Hofmann, S. (2008) · Der Orthopäde · doi:10.1007/s00132-008-1288-3 · Cited by 6
Evolution of the patellar sesamoid bone in mammalsPreprint
Samuels, M. E., Regnault, S., & Hutchinson, J. R. (2016) · doi:10.7287/peerj.preprints.2594v1 · Cited by 6
Herrmann, S., Lenz, R., Geier, A., Lehner, S., Souffrant, R., Woernle, C., Tischer, T., & Bader, R. (2012) · Der Orthopäde · doi:10.1007/s00132-011-1851-1 · Cited by 6
Effect of an UHMWPE patellar component on stress fields in the patella: a finite element analysis
Lee, Y. S., Lee, T. Q., & Keyak, J. H. (2008) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-008-0628-5 · Cited by 6
A new approach for the dynamic modelling of the human knee
Sancisi, N. (2008) · AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna) · doi:10.6092/unibo/amsdottorato/953 · Cited by 6
Selected Knee Osteotomies and Meniscal Replacement: Effects on Dynamic Intra-Joint Loading
Andrish, J. T., KAMBIC, H. E., Valdevit, A. D. C., Kuroda, R., Parker, R. D., Aronowitz, E. R., & Elster, T. (2001) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200100022-00012 · Cited by 6
Chan, K. M., Qin, L., Li, C. K., Hung, L. K., Tang, C. Y., & Rolf, C. (2000) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00029-2 · Cited by 6
In-vivo quantification of patellofemoral joint contact force using a mathematical model
Baker, S. N. (2002) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/16894 · Cited by 6
The biomechanics of the patella
Grelsamer, R. P., & Gould, J. (2012) · Springer eBooks · doi:10.1007/978-2-287-99353-4_44 · Cited by 5
Zelada, S. R. B., Leão, R. V., da Silva, A. G. M., Lôbo, C. F. T., Godoy‐Santos, A. L., Helito, P. V. P., Helito, C. P., & Gobbi, R. G. (2025) · Skeletal Radiology · doi:10.1007/s00256-025-05011-3 · Cited by 5
Biomecánica de la articulación de la rodilla tras lesiones ligamentosas
Peña, E., Calvo, B., & Doblaré, M. (2006) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 4
Boudali, A. M., Shatrov, J. G., Abe, K., Zavala, M., Parker, D. A., Walter, W. L., & Clarke, E. (2025) · SICOT-J · doi:10.1051/sicotj/2025043 · Cited by 4
Lone, A. S., Kanth, S. A., Harmain, G. A. U., & Jameel, A. (2023) · Iranian Journal of Science and Technology Transactions of Mechanical Engineering · doi:10.1007/s40997-023-00605-5 · Cited by 4
Wang, J., Yang, Y., Guo, D., Wang, S., Fu, L., & Li, Y. (2019) · Applied Sciences · doi:10.3390/app9204301 · Cited by 3
Tatarunas, A. C., Matera, J. M., Miglino, M. A., Pinto, A. C. B. D. C. F., Lorigados, C. A. B., & Gomes, L. F. F. (2019) · Ciência Animal Brasileira · doi:10.1590/1089-6891v20e-47857 · Cited by 3
Ossäre und chondrale Anatomie des patellofemoralen Gelenks
Tecklenburg, K., Dejour, D. H., Hoser, C., & Fink, C. (2005) · Arthroskopie · doi:10.1007/s00142-005-0305-3 · Cited by 3
Patellar Tracking in Computer-Assisted Surgery
Belvedere, C., Ensini, A., Leardini, A., Feliciangeli, A., & Giannini, S. (2012) · Springer eBooks · doi:10.1007/978-3-642-31430-8_18 · Cited by 3
Shatrov, J. G., Boudali, A. M., Abe, K., Parker, D. A., Clarke, E., & Walter, W. L. (2026) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70282 · Cited by 3
Spencer, J. A. (2016) · MOJ Orthopedics & Rheumatology · doi:10.15406/mojor.2016.05.00163 · Cited by 3
Three-DimensionalDynamic AnatomicalModeling of the Human Knee Joint
Hefzy, M. S., & Abdel-Rahman, E. M. (2000) · CRC Press eBooks · doi:10.1201/9781420049541.ch-01 · Cited by 3
Beck, J. J., Boguszewski, D. V., Joshi, N. B., Cheung, E. C., Bowen, R. E., & Oppenheim, W. L. (2018) · Journal of Pediatric Orthopaedics B · doi:10.1097/bpb.0000000000000527 · Cited by 3
Influencia de la altura rotuliana sobre la biomecánica de la rodilla
Campillo, G. A. (2016) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · Cited by 3
Urriolagoitia-Sosa, G., Romero-Ángeles, B., Méndez-Romero, D., Rodríguez-Martínez, R., Torres‐SanMiguel, C. R., Martínez-Reyes, J., Hernández-Vázquez, R. A., & Urriolagoitia-Calderón, G. (2018) · Advanced structured materials · doi:10.1007/978-3-319-79005-3_9 · Cited by 2
Rath, B., Asseln, M., Betsch, M., Prescher, A., Tingart, M., & Eschweiler, J. (2018) · BioMed Research International · doi:10.1155/2018/7189714 · Cited by 2
Development and Validation of a Kinematically-Driven Computational Model of the Patellofemoral Joint
Gustafson, J. A. (2017) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Three-dimensional finite element modeling of human knee joint
Niasar, E. H. A., & Li, L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90597-8.00002-5 · Cited by 2
Cazenave, M. (2022) · Bulletins et Mémoires de la Société d anthropologie de Paris · doi:10.4000/bmsap.10118 · Cited by 2
Cazenave, M., Radovčić, D., Hoffman, J., & Macchiarelli, R. (2020) · Paléo · doi:10.4000/paleo.5167 · Cited by 2
Thijs, Y. (2009) · Ghent University Academic Bibliography (Ghent University) · Cited by 2
Explicit Finite Element Modeling of Knee Mechanics during Simulated Dynamic Activities
Baldwin, M. A. (2009) · Digital Commons - DU (University of Denver) · Cited by 2
Machado, J. C. F. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/tg5s-hk26 · Cited by 2
Kleist, E., Henke, P., Woernle, C., Bader, R., Kebbach, M., & Zierath, J. (2025) · Arthroplasty · doi:10.1186/s42836-025-00351-w · Cited by 2
Prosthetic Design and Patellofemoral Function
Robie, B. H., & Rosenthal, D. E. (2001) · Springer eBooks · doi:10.1007/978-3-7091-6185-2_2 · Cited by 2
Aseptic loosening and anterior knee pain in high-flexion total knee arthroplasty
van de Groes, S. A. W. (2014) · Radboud Repository (Radboud University) · Cited by 2
Shatrov, J. G., Boudali, A. M., Abe, K., Parker, D. A., Clarke, E., & Walter, W. L. (2025) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70201 · Cited by 2
Yu, M., Xu, Y., Wang, Y., Hu, M., Yang, X., Zhu, W., Weng, X., & Feng, B. (2025) · The Journal of Arthroplasty · doi:10.1016/j.arth.2025.05.101 · Cited by 2
Numerical methods for determining local motions of human knee joint
Fekete, G., & Csizmadia, B. (2008) · Ghent University Academic Bibliography (Ghent University) · Cited by 2
Vertiefung - Konservative Therapie für Sportler mit Knorpelschaden
Wondrasch, B., & Aldrian, S. M. (2013) · Sportphysio · doi:10.1055/s-0033-1359415 · Cited by 2
Modeling The Spatiotemporal Dynamics Of Cells In The Lung
Pothen, J. J. (2016) · ScholarWorks -A service of University of Vermont Libraries (University of Vermont) · Cited by 1
Optimisation des prothèses totales de genou postéro-stabilisées par la méthode des éléments finis
Dagneaux, L., Canovas, F., & Jourdan, F. (2023) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2023.06.022 · Cited by 1
Hassani, W. (2014) · theses.fr (ABES) · doi:10.70675/2c61d97dzb025z4240z96a5z8dfa8f6bc872 · Cited by 1
Computational modeling of knee joint function based on CT arthrography
Venäläinen, M. (2017) · UEF eRepo (University of Eastern Finland) · Cited by 1
Finite Element Modeling and Analysis of Prosthetic Knee Joint- A Review
Shashishekar, C., & Sanjay, S. J. (2021) · IJIREEICE · doi:10.17148/ijireeice.2021.91012 · Cited by 1
Estudo biomecânico dos meniscos na articulação do joelho humano
Carvalho, D. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/ntjc-xp08 · Cited by 1
Vergleichende prospektive klinisch radiologische1-Jahres-Ergebnisse nach MPFL-Rekonstruktion
Beermann, I. (2013) · mediaTUM (Technical University of Munich) · Cited by 1
Adductor/Abductor Dysfunction Causing Patellofemoral Syndrome in Cyclists
Reitz, R. D. (2024) · Journal Of Science & Cycling · doi:10.28985/1324.jsc.03 · Cited by 1
McWalter, E. J. (2010) · cIRcle (University of British Columbia) · doi:10.14288/1.0071575 · Cited by 1
Benavente, S., & Villagra, J. (2019) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-019-02337-1 · Cited by 1
Schäden am patellofemoralen Gelenk durch Krafttraining
Jagodzinski, M., Haasper, C., & Krettek, C. (2009) · Der Unfallchirurg · doi:10.1007/s00113-009-1621-2 · Cited by 1
Osteotomies Around the Patellofemoral Joint
Biedert, R. M., & Tscholl, P. M. (2011) · Springer eBooks · doi:10.1007/978-0-85729-507-1_34 · Cited by 1
Sathyanarayana, D., Tavakoli, M. S., Atkinson, P. J., Anseth, S. D., Raley, T. J., & Walter, N. E. (2007) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2007-01-1162 · Cited by 1
Osteotomies Around the Patellofemoral Joint
Biedert, R. M., & Tscholl, P. M. (2012) · Springer eBooks · doi:10.1007/978-1-4471-4501-1_7 · Cited by 1
In-vitro measurement of the human knee joint motion during quadriceps leg raising
Kim, S. (1998) · KSME International Journal · doi:10.1007/bf02945723 · Cited by 1
Rayi, S., Yokata, H., & Anwar, S. (2019) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2019.126025 · Cited by 1
Jafari, A., Farahmand, F., & Meghdari, A. F. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353384 · Cited by 1
Biomechanical research of Szent István university
Csizmadia, B., & Fekete, G. (2010) · International Journal Sustainable Construction & Design · doi:10.21825/scad.v1i1.20407 · Cited by 1
Msc.Adams programrendszer felhasználása a biomechanikai modellezésben
Fekete, G., & Kátai, L. (2008) · Fiatal Műszakiak Tudományos Ülésszaka · doi:10.36243/fmtu-2008.23 · Cited by 1
COMPUTATIONAL AND EXPERIMENTAL ASSESSMENT OF TOTAL KNEE REPLACEMENT MOTION
Moran, M. F. (2005) · Cited by 1
Mediavilla, E. R. (2017) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
The effect of patellofemoral kinematics on joint congruence and cartilage stresses
Kralovic, B. J. (2000) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/19766 · Cited by 1
From Shape to Function: Investigating Knee Joint Mechanics Through Statistical Shape Modeling
Deng, R. (2024) · doi:10.11575/prism/47744 · Cited by 1
Impact of ACL Injury on Patellar Cartilage Thickness
Leveillee, E. (2016) · ScholarWorks -A service of University of Vermont Libraries (University of Vermont)
Patellofemoral Pain and Rehabilitation
Manton, C. (2015) · Orthopaedic Section, APTA, Inc. eBooks · doi:10.17832/isc.2015.25.3.3.3
Specimen-Specific Natural, Pathological, and Implanted Knee Mechanics Using Finite Element Modeling
Ali, A. A. (2017) · Digital Commons - DU (University of Denver)
Principles of biomechanics and tissue regeneration
Watson Arulsingh, D. R., & Kandakurti, P. K. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90597-8.00041-4
Al-Sahhoum, A. (2015) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-4911
IN VITRO PATELLAR TRACKING PATTERN MEASUREMENT BASED ON MOVING LEAST SQUARES CURVE FITTING
QIAN, L. W., WANG, J. P., Ye, M., & WANG, C. T. (2013) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519413500310
Elliott, B., & Mimnaugh, K. D. (2025) · Journal of Testing and Evaluation · doi:10.1520/jte20240112
Stockinger, M. (2014) · Electronic Theses of LMU Munich (Ludwig-Maximilians-Universität München) · doi:10.5282/edoc.16590
Dempsey, E. J. (2005) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/11897
Quantitative computed tomography analysis of patellar subchondral bone density
Burnett, W. D. (2013) · HARVEST (University of Saskatchewan)
Metadata
- Authors
- Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1995-11
- Volume
- 28
- Issue
- 11
- Pages
- 1265-1279
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2166361133
- Cited by
- 180
- References
- 76
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.