Force and velocity measured for single kinesin molecules
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We measured the force-velocity curves of single kinesin molecules attached to silica beads moving in an in vitro motility assay. Optical trapping interferometry was used to track movement with subnanometer precision and to apply calibrated, pN-sized forces to the beads. Velocity decreased linearly with increasing force, and kinesin molecules moved against applied loads of up to 5-6 pN. Comparison of force-velocity curves at limiting and saturating ATP concentrations suggests that the load-dependent diminution in kinesin velocity may be due to a decrease in the net displacement per molecule of ATP hydrolyzed, not simply to a slowing of the ATP turnover rate; kinesin would therefore appear to be a loosely coupled motor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Deviations from that cycle, such as those resulting in backsteps towards the microtubule minus end, occur only rarely, or in response to external loads that approach or exceed the stall force9.”
From A universal pathway for kinesin stepping (2011) · cites this paper as [9]
In the citing paper
“Individual WT motors were motile in the absence of load, stalled on the microtubule when approaching the detachment force, and detached from the microtubule at an average force of 4.6 ± 0.8 pN (Figure 3B,C), consistent with previous studies (Khalil et al., 2008; Svoboda and Block, 1994).”
From Neck linker docking is critical for Kinesin-1 force generation in cells but at a cost to motor speed and processivity (2019) · cites this paper as Svoboda and Block, 1994
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030
Muscle Structure and Theories of Contraction
Huxley, A. F. (1957) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30128-8 · Cited by 2,318 · cited 2×
“The crossbridge model proposed by A. F. Huxley was among the first to explain existing data and made quantitative predictions for muscle (Huxley, 1957).”
BackgroundMethodIdentification of a novel force-generating protein, kinesin, involved in microtubule-based motility
VALE, R., REESE, T., & SHEETZ, M. (1985) · Cell · doi:10.1016/s0092-8674(85)80099-4 · Cited by 1,993
Single myosin molecule mechanics: piconewton forces and nanometre steps
Finer, J. T., Simmons, R. M., & Spudich, J. A. (1994) · Nature · doi:10.1038/368113a0 · Cited by 1,915 · cited 1×
“Recently, stepwise displacements and corresponding forces for the actomyosin system were reported, using both optical trapping (Finer et al., 1994) and flexible glass microneedle technologies (Ishijima et al., 1994).”
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910 · cited 17×
“The required nonlinear voltage sequence for this movement was determined separately by nanometer-level video tracking of single beads bound to a coverglass and calibrated against a diamond-ruled grid with 10 urn spacing (Gelles et al., 1988; Svoboda et al., 1993).”
BackgroundMethodResultInfluentialSelf-citationBiological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792 · cited 8×
“Large distance from the coverglass affects trapping force, mainly owing to the increasing spherical aberration in light (Svoboda and Block, 1994), and it is unclear whether calibration experiments were carried out at the same distance from the coverglass surface as the actual assays, or adjusted for any possible diffe…”
BackgroundMethodInfluentialSelf-citationForces of a single-beam gradient laser trap on a dielectric sphere in the ray optics regime
Ashkin, A. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81860-x · Cited by 1,681
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038 · cited 2×
“We conclude that single kinesin molecules suffice to move beads, confirming earlier work (Howard et al., 1989; Block et al., 1990).”
BackgroundResultSelf-citationFluid Mechanics of Propulsion by Cilia and Flagella
Brennen, C., & Winet, H. (1977) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.09.010177.002011 · Cited by 959
Movement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885 · cited 3×
“We conclude that single kinesin molecules suffice to move beads, confirming earlier work (Howard et al., 1989; Block et al., 1990).”
BackgroundResultTracking kinesin-driven movements with nanometre-scale precision
Gelles, J., Schnapp, B. J., & Sheetz, M. P. (1988) · Nature · doi:10.1038/331450a0 · Cited by 819 · cited 2×
“At very low loads, kinesin velocity was measured using high resolution video tracking of the centroid of the bead (Gelles et al., 1988).”
MethodMicrotubule assembly nucleated by isolated centrosomes
Mitchison, T., & Kirschner, M. (1984) · Nature · doi:10.1038/312232a0 · Cited by 777
Hirokawa, N., Pfister, K. K., Yorifuji, H., Wagner, M. C., Brady, S. T., & Bloom, G. S. (1989) · Cell · doi:10.1016/0092-8674(89)90691-0 · Cited by 477
Force of Single Kinesin Molecules Measured with Optical Tweezers
Kuo, S. C., & Sheetz, M. P. (1993) · Science · doi:10.1126/science.8469975 · Cited by 424 · cited 1×
“…the maximum force produced by kinesin molecules have generated disparate results: 1.9 f 0.4 pN measured with optical tweezers in a MT gliding assay (Kuo and Sheetz, 1993), >5 pN measured with optical tweezers in a moving-bead assay (Svoboda et al., 1993), and 0.12 * 0.03 pN measured with a…”
BackgroundInfluentialThe relation between the work performed and the energy liberated in muscular contraction
Fenn, W. O. (1924) · The Journal of Physiology · doi:10.1113/jphysiol.1924.sp002141 · Cited by 370 · cited 1×
“This is a molecular manifestation of the Fenn effect, whereby the energy released by muscle during active shortening is higher than during isometric contraction (Fenn, 1924; Bagshaw, 1993).”
BackgroundEvidence for alternating head catalysis by kinesin during microtubule-stimulated ATP hydrolysis.
Hackney, D. D. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.15.6865 · Cited by 351 · cited 1×
“Recombinant fragments of kinesin molecules, consisting of dimers of motor domains without the tail, have substantially higher turnover rates (k-r = 90/s), consistent with 1:l coupling (Hackney, 1994).”
BackgroundKinesin follows the microtubule's protofilament axis.
Ray, S., Meyhöfer, E., Milligan, R. A., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.121.5.1083 · Cited by 341 · cited 1×
“Kinesin accelerated up to 1 000-fold by microtubules(MTs), and the moves parallel to the MT protofilament (Ray et al., 1993; MT-activated ATPase obeys Michaelis-Menten kinetics Kamimura and Mandelkow, 1992; Gelies et al., 1988).”
BackgroundBloom, G. S., Wagner, M. C., Pfister, K. K., & Brady, S. T. (1988) · Biochemistry · doi:10.1021/bi00409a043 · Cited by 284 · cited 1×
“%) were run using a TLS55 rotor and TL-100 tabletop ultracentrifuge (Beckman) for 4 hr at 55,006 rpm and 4OC (Bloom et al., 1966).”
Method1 Transient-State Kinetic Analysis of Enzyme Reaction Pathways
(1992) · The Enzymes · doi:10.1016/s1874-6047(08)60019-0 · Cited by 273 · cited 2×
“7. is independent of c, while r,,(c) = 4/c, and both quantities have units of time: in general, 4 and f. are complicated functions of the biochemical rate constants (Johnson, 1992).”
BackgroundSliding distance of actin filament induced by a myosin crossbridge during one ATP hydrolysis cycle
Yanagida, T., Arata, T., & Oosawa, F. (1985) · Nature · doi:10.1038/316366a0 · Cited by 260
Kinesin ATPase: rate-limiting ADP release
Hackney, D. D. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.17.6314 · Cited by 239
Porters versus rowers: a unified stochastic model of motor proteins.
Leibler, S., & Huse, D. A. (1993) · The Journal of cell biology · doi:10.1083/jcb.121.6.1357 · Cited by 233 · cited 1×
“Our results are in broad agreement with the model of Leibler and Huse, which predicts a linear force-velocity curve for the case of strain-independent rate constants for transitions between states (Leibler and Huse, 1993).”
ResultIdentification of globular mechanochemical heads of kinesin
Scholey, J. M., Heuser, J., Yang, J. T., & Goldstein, L. S. B. (1989) · Nature · doi:10.1038/338355a0 · Cited by 228 · cited 1×
“Assuming a random distribution of motors over the bead surface, and allowing an 80 nm reach for the kinesin tether (Hirokawa et al., 1989; Scholeyet al., 1989), weestimate theprobability of two randomly attached kinesin molecules simultaneously binding a MT to be <0.02.”
BackgroundInfluentialBovine brain kinesin is a microtubule-activated ATPase
Kuznetsov, S. A., & Gelfand, V. I. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.22.8530 · Cited by 217
Physical properties of cytoplasm
Luby-Phelps, K. (1994) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(94)90109-0 · Cited by 217 · cited 1×
“In vivo, it is unlikely that kinesin and related motors experience a significant viscous load (Luby-Phelps, 1993).”
BackgroundSingle-Molecule Analysis of the Actomyosin Motor Using Nano-Manipulation
Ishijima, A., Harada, Y., Kojima, H., Funatsu, T., Higuchi, H., & Yanagida, T. (1994) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1994.1336 · Cited by 207 · cited 2×
“, 1994) and flexible glass microneedle technologies (Ishijima et al., 1994).”
BackgroundOptical measurement of picometer displacements of transparent microscopic objects
Denk, W., & Webb, W. W. (1990) · Applied Optics · doi:10.1364/ao.29.002382 · Cited by 177 · cited 3×
“The optical trapping interferometer (Svoboda et al., 1993) consists of optical tweezers (a single-beam gradient force optical trap) (Ashkin et al., 1986) combined with a dualbeam interferometer (Denk and Webb, 1990) (Figure 1).”
BackgroundMethodKinesin undergoes a 9 S to 6 S conformational transition
Hackney, D. D., Levitt, J. D., & Suhan, J. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)42499-4 · Cited by 175 · cited 1×
“In support of this explanation, Hackney has recently found that native kinesin molecules in solution are mostly in a closed conformation , with the tail folded back against the motor domain (Hackney et al., 1992).”
BackgroundThe loose coupling mechanism in molecular machines of living cells
Oosawa, F., & Hayashi, S. (1986) · Advances in Biophysics · doi:10.1016/0065-227x(86)90005-5 · Cited by 117
Correlation between the ATPase and microtubule translocating activities of sea urchin egg kinesin
Cohn, S. A., Ingold, A. L., & Scholey, J. M. (1987) · Nature · doi:10.1038/328160a0 · Cited by 107
Kinesin swivels to permit microtubule movement in any direction.
Hunt, A. J., & Howard, J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.24.11653 · Cited by 105 · cited 1×
“It has also been suggested that the slowing of sperm heads moving in the centrifugal microscope may be due to something besides an inertial effect, and that the force thereby obtained is artifactually low (Hunt and Howard, 1993).”
BackgroundGilbert, S. P., & Johnson, K. A. (1993) · Biochemistry · doi:10.1021/bi00068a028 · Cited by 88 · cited 1×
“…have been performed, there is little consensus as to the maximum value of the turnover rate per kinesin molecule, &r, particularly under conditions that obtain for in vitro assays (Kuznetsov and Gelfand, 1986; Cohn et al., 1987; Hackney, 1988; Hackney et al., 1991; Gilbert and Johnson, 1993).”
BackgroundCharacterization of α2β2 and α2 forms of kinesin
Hackney, D. D., Levitt, J. D., & Wagner, D. D. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91490-4 · Cited by 80 · cited 1×
“…have been performed, there is little consensus as to the maximum value of the turnover rate per kinesin molecule, &r, particularly under conditions that obtain for in vitro assays (Kuznetsov and Gelfand, 1986; Cohn et al., 1987; Hackney, 1988; Hackney et al., 1991; Gilbert and Johnson, 1993).”
Background[53] Viewing single microtubules by video light microscopy
Schnapp, B. J. (1986) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(86)34121-1 · Cited by 79 · cited 17×
“MTs bound tightly to this surface, mainly with their long axes parallel to the flow direction, thereby parallel to the direction of interferometer sensitivity (see text).”
MethodInfluentialCellular roles of kinesin and related proteins
Hoyt, M. A. (1994) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(94)90117-1 · Cited by 76 · cited 1×
“During mitotic and meiotic movements (Hoyt, 1994) loads may also arise from elastic forces in strained MTs.”
BackgroundMyosin step size: Estimates from motility assays and shortening muscle
Burton, K. (1992) · Journal of Muscle Research and Cell Motility · doi:10.1007/bf01738249 · Cited by 48
Nano-manipulation of actomyosin molecular motors in vitro: a new working principle
Yanagida, T., Harada, Y., & Ishijima, A. (1993) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(93)90064-t · Cited by 48 · cited 1×
“It has therefore been suggested that mechanoenzymes might somehow undergo several steps per ATP hydrolyzed (1 :many coupling) (Yanagida et al., 1993; Taylor, 1993), an explanation first advanced to explain discrepancies in measurements in the actomyosin system (Yanagida et al., 1985; Burton, 1992).”
BackgroundTubulin protofilaments and kinesin-dependent motility.
Kamimura, S., & Mandelkow, E. (1992) · The Journal of cell biology · doi:10.1083/jcb.118.4.865 · Cited by 46 · cited 1×
“Kinesin accelerated up to 1 000-fold by microtubules(MTs), and the moves parallel to the MT protofilament (Ray et al., 1993; MT-activated ATPase obeys Michaelis-Menten kinetics Kamimura and Mandelkow, 1992; Gelies et al., 1988).”
BackgroundNucleotide-free Kinesin Hydrolyzes ATP with Burst Kinetics
Hackney, D. D., Malik, A. S., & Wright, K. W. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)71570-6 · Cited by 40
Force–velocity relationships in kinesin-driven motility
Hall, K., Cole, D. G., Yeh, Y., Scholey, J. M., & Baskin, R. J. (1993) · Nature · doi:10.1038/364457a0 · Cited by 27 · cited 2×
“…disparate results: 1.9 f 0.4 pN measured with optical tweezers in a MT gliding assay (Kuo and Sheetz, 1993), >5 pN measured with optical tweezers in a moving-bead assay (Svoboda et al., 1993), and 0.12 * 0.03 pN measured with a centrifugal microscope in a sperm gliding assay (Hall et al., 1993).”
MethodInfluentialVariations on the theme of movement
Taylor, E. W. (1993) · Nature · doi:10.1038/361115a0 · Cited by 15 · cited 1×
“It has therefore been suggested that mechanoenzymes might somehow undergo several steps per ATP hydrolyzed (1 :many coupling) (Yanagida et al., 1993; Taylor, 1993), an explanation first advanced to explain discrepancies in measurements in the actomyosin system (Yanagida et al., 1985; Burton, 1992).”
BackgroundCRC handbook of chemistry and physics. Sixty-seventh edition
Weast, R. C. (1986) · Cited by 3
Cited by
Brownian motors: noisy transport far from equilibrium
Reimann, P. (2002) · Physics Reports · doi:10.1016/s0370-1573(01)00081-3 · Cited by 2,589
“On the other hand, taking into account that a rather “heavy” load is attached to the motor, may render the assumption of an uniformly moving backbone not so bad [582].”
BackgroundInfluentialMICROTUBULE POLYMERIZATION DYNAMICS
Desai, A., & Mitchison, T. J. (1997) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.13.1.83 · Cited by 2,563
“For comparison, the stall force for a single kinesin is≈5 pN (Svoboda & Block 1994).”
BackgroundSingle-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
“Early applications of single-molecule force and displacement measurements included the characterization of conventional motor proteins such as kinesin”
BackgroundNeuman, K. C., & Block, S. M. (2004) · Review of Scientific Instruments · doi:10.1063/1.1785844 · Cited by 2,165
Self-citationJülicher, F., Ajdari, A., & Prost, J. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.1269 · Cited by 1,870
Metadata
- Authors
- Svoboda, K., & Block, S. M.
- Affiliations
- Harvard University (US)
- Princeton University (US)
- ORCID
- Svoboda, Karel
- Venue
- Cell
- Publisher
- Elsevier BV
- Published
- 1994-06
- Volume
- 77
- Issue
- 5
- Pages
- 773-784
- ISSN
- 0092-8674 (ISSN-L)
- OpenAlex
- W2170640142
- Semantic Scholar
- 695d8b76bd2edf0e513fbcf461fe0c62d7b64af3
- Cited by
- 909
- References
- 43
- Citations by year
- 2026: 19 · 2025: 19 · 2024: 16 · 2023: 22 · 2022: 23 · 2021: 34 · 2020: 21 · 2019: 32 · 2018: 24 · 2017: 34 · 2016: 41 · 2015: 31 · 2014: 39 · 2013: 38 · 2012: 33
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Cell (publishedVersion)
- PubMed (publishedVersion)
- Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) (acceptedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- kinesin, force-velocity relationship, single-molecule force measurement, in vitro motility assay, silica beads, ATP hydrolysis, motor protein mechanics
- MeSH terms
- Adenosine Triphosphate, Animals, Biomechanical Phenomena, Hydrolysis, Interferometry, Kinetics, Silicon Dioxide, Thermodynamics, Kinesins, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.