Local anaesthetic block protects against electrically-induced damage in peripheral nerve
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This study is one of a series addressing the mechanisms involved in the production of neural damage caused by continuous, prolonged electrical stimulation of peripheral nerve. It has been previously shown that sustained, high frequency electrical stimulation of the cat's peroneal nerve may cause irreversible neural damage in the form of axonal degeneration of the large myelinated fibres. In this study we demonstrate that blocking the action potentials on most of the nerve fibres with local anaesthetics (10% procaine or 2% lidocaine) almost completely prevents the axonal degeneration. The abolition of axonal injury by local anaesthetic block strongly suggests that the electrically-induced damage is due to prolonged electrical excitation of axons. Furthermore, since less than complete suppression of the induced neural activity by local anaesthetic engenders essentially complete sparing of all axons, our results suggest that the damage to individual axons derives, at least in part, from stimulation-induced global changes in the nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacral anterior root stimulators for bladder control in paraplegia
Brindley, G. S., Polkey, C. E., & Rushton, D. N. (1982) · Spinal Cord · doi:10.1038/sc.1982.65 · Cited by 311
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
Self-citationLong-term pain control by direct peripheral-nerve stimulation.
Nashold, B. S., Goldner, J. L., Mullen, J. B., & Bright, D. S. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00001 · Cited by 184
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177
Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
Self-citationLight and electron microscopic studies of phrenic nerves after long-term electrical stimulation
Kim, J. H., Manuelidis, E. E., Glenn, W. W. L., Fukuda, Y., Cole, D. S., & Hogan, J. F. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.58.1.0084 · Cited by 47
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
“Agnew et al. (1990) studied stimulation of cat peroneal nerve, and concluded that the damage to an axon is due to the total induced neural activity having some effect on the extraaxonal environment .”
BackgroundTissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
“…materials, such as platinum or iridium oxide, suggests that neural hyperactivity rather than irreversible electrode processes is the first damage mechanism encountered as the intensity and frequency of stimulation are increased (Agnew and McCreery 1990, Agnew et al 1990, 1993, McCreery et al 1994).”
BackgroundNerve conduction block utilising high-frequency alternating current
Kilgore, K. L., & Bhadra, N. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344716 · Cited by 284
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
Considerations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184
Self-citation
Metadata
- Authors
- Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1990-07-01
- Volume
- 12
- Issue
- 4
- Pages
- 301-308
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W1976441265
- Cited by
- 49
- References
- 6
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.