The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors
Open accessAbstract
A copolymer containing 88% 2-hydroxyethyl methacrylate (HEMA), 9% poly(ethylene glycol) (MW 18.5 kDa) tetra-acrylate and 3% ethylene dimethacrylate was prepared and evaluated for use as a biocompatible interface between glucose biosensors and tissue in the rat. The glucose sensor utilizes glucose oxidase that is electrically 'wired' to a gold current collector by a reduction-oxidation polymer. Coatings of the copolymer were crosslinked in situ on the sensors using long wavelength ultraviolet light and 2,2-dimethoxy-2-phenyl-acetophenone as the initiator. The effect these films had on the current response to glucose was measured. Over a glucose concentration range of 0-30 mM, the average percentage decrease in response was 45 +/- 28% (mean +/- 95% confidence interval) at 37 degrees C for films that were about 0.1 mm thick, an acceptable value. Copolymer-treated and control electrodes were implanted in the intrascapular subcutaneous tissue of male Sprague-Dawley rats for three days. The explanted samples were evaluated using scanning electron microscopy. The control electrodes were highly encapsulated with fibrous material, while the copolymer-treated electrodes induced much less encapsulation. The results show this copolymer to be a candidate as a biocompatible coating for electrically wired oxidoreductase-based subcutaneous biosensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“substrates with the hydrogel coating had markedly less fibrous encapsulation relative to controls.143”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [143]
Citations
Cites
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Gregg, B. A., & Heller, A. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a046 · Cited by 275
Self-citationDesai, N. P., & Hubbell, J. A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90193-e · Cited by 270
Self-citationRapid photopolymerization of immunoprotective gels in contact with cells and tissue
Pathak, C. P., Sawhney, A. S., & Hubbell, J. A. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00047a065 · Cited by 182
Self-citationApplication of Chronic Intravascular Blood Glucose Sensor in Dogs
Armour, J. C., Lucisano, J. Y., Bd, M., & Gough, D. A. (1990) · Diabetes · doi:10.2337/diab.39.12.1519 · Cited by 175
Sawhney, A. S., & Hubbell, J. A. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90180-v · Cited by 156
Self-citationPishko, M. V., Michael, A. C., & Heller, A. (1991) · Analytical Chemistry · doi:10.1021/ac00020a014 · Cited by 148
Self-citationGombotz, W. R., Guanghui, W., & Hoffman, A. (1989) · Journal of Applied Polymer Science · doi:10.1002/app.1989.070370108 · Cited by 123
Elimination of electrooxidizable interferant-produced currents in amperometric biosensors
Maidan, R., & Heller, A. (1992) · Analytical Chemistry · doi:10.1021/ac00047a003 · Cited by 117
Self-citationPickup, J. C., Shaw, G. W., & Claremont, D. J. (1989) · Diabetologia · doi:10.1007/bf00265097 · Cited by 114
Csöregi, E., Quinn, C. P., Schmidtke, D. W., Lindquist, S., Pishko, M. V., Ye, L., Katakis, I., Hubbell, J. A., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00091a022 · Cited by 110
Self-citationPoitout, V., Moatti-Sirat, D., Reach, G., Zhang, Y., Wilson, G. S., Lemonnier, F., & Klein, J. C. (1993) · Diabetologia · doi:10.1007/bf00404077 · Cited by 95
Turner, R. F. B., Harrison, D. J., & Rojotte, R. V. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90003-s · Cited by 91
Application of chronic intravascular blood glucose sensor in dogs
Armour, J. C., Lucisano, J. Y., Bd, M., et al. (1990) · Diabetes · doi:10.2337/diabetes.39.12.1519 · Cited by 74
In-vivo behaviour of hypodermically implanted microfabricated glucose sensors
Koudelka, M., Rohner‐Jeanrenaud, F., Terrettaz, J., Bobbioni-Harsch, E., de Rooij, N. F., & Jeanrenaud, B. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)85005-h · Cited by 72
Grainger, D. W., Nojiri, C., Okano, T., & Kim, S. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230903 · Cited by 54
Determination of urate in undiluted whole blood by enzyme electrode
Keedy, F. H., & Vadgama, P. M. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)85046-y · Cited by 43
Poly(vinyl alcohol)-heparin hydrogels as sensor catheter membranes
Brinkman, E., Does, L. V. D., & Bantjes, A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90134-v · Cited by 34
Short-term in vivo operation of a glucose sensor.
Gough, D. A., Armour, J. C., Jy, L., & Bd, M. (1986) · PubMed · Cited by 21
Glucose electrochemical probe with extended linearity for whole blood
Mascini, M., Selleri, S., & Riviello, M. (1989) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(89)80158-x · Cited by 8
Cited by
Sorted by citations
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationPhotopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Barton, S. C., Gallaway, J., & Atanassov, P. B. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,396
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Self-citation
Metadata
- Authors
- Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A.
- Affiliations
- The University of Texas at Austin (US)
- Corresponding author
- Hubbell, Jeffrey A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 16
- Issue
- 5
- Pages
- 389-396
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1988024774
- Cited by
- 172
- References
- 19
- Citations by year
- 2025: 5 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 4 · 2014: 8 · 2013: 8 · 2012: 7
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- National Institutes of Health (5r01dk042015-07)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK42015)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- 2-hydroxyethyl methacrylate, ethylene glycol dimethacrylate, glucose biosensor, biocompatibility, subcutaneous implantation, glucose oxidase, gold electrode, fibrous encapsulation, in situ crosslinking, 2,2-dimethoxy-2-phenylacetophenone
- MeSH terms
- Acrylates, Animals, Biocompatible Materials, Calibration, Cross-Linking Reagents, Glucose, Male, Methacrylates, Photochemistry, Polyethylene Glycols, Polymers, Ultraviolet Rays, Biosensing Techniques, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review