The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors
Open accessAbstract
A copolymer containing 88% 2-hydroxyethyl methacrylate (HEMA), 9% poly(ethylene glycol) (MW 18.5 kDa) tetra-acrylate and 3% ethylene dimethacrylate was prepared and evaluated for use as a biocompatible interface between glucose biosensors and tissue in the rat. The glucose sensor utilizes glucose oxidase that is electrically 'wired' to a gold current collector by a reduction-oxidation polymer. Coatings of the copolymer were crosslinked in situ on the sensors using long wavelength ultraviolet light and 2,2-dimethoxy-2-phenyl-acetophenone as the initiator. The effect these films had on the current response to glucose was measured. Over a glucose concentration range of 0-30 mM, the average percentage decrease in response was 45 +/- 28% (mean +/- 95% confidence interval) at 37 degrees C for films that were about 0.1 mm thick, an acceptable value. Copolymer-treated and control electrodes were implanted in the intrascapular subcutaneous tissue of male Sprague-Dawley rats for three days. The explanted samples were evaluated using scanning electron microscopy. The control electrodes were highly encapsulated with fibrous material, while the copolymer-treated electrodes induced much less encapsulation. The results show this copolymer to be a candidate as a biocompatible coating for electrically wired oxidoreductase-based subcutaneous biosensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“substrates with the hydrogel coating had markedly less fibrous encapsulation relative to controls.143”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [143]
Citations
Cites
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Gregg, B. A., & Heller, A. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a046 · Cited by 275
Self-citationDesai, N. P., & Hubbell, J. A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90193-e · Cited by 270
Self-citationRapid photopolymerization of immunoprotective gels in contact with cells and tissue
Pathak, C. P., Sawhney, A. S., & Hubbell, J. A. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00047a065 · Cited by 182
Self-citationApplication of Chronic Intravascular Blood Glucose Sensor in Dogs
Armour, J. C., Lucisano, J. Y., Bd, M., & Gough, D. A. (1990) · Diabetes · doi:10.2337/diab.39.12.1519 · Cited by 175
Sawhney, A. S., & Hubbell, J. A. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90180-v · Cited by 156
Self-citationPishko, M. V., Michael, A. C., & Heller, A. (1991) · Analytical Chemistry · doi:10.1021/ac00020a014 · Cited by 148
Self-citationGombotz, W. R., Guanghui, W., & Hoffman, A. (1989) · Journal of Applied Polymer Science · doi:10.1002/app.1989.070370108 · Cited by 123
Elimination of electrooxidizable interferant-produced currents in amperometric biosensors
Maidan, R., & Heller, A. (1992) · Analytical Chemistry · doi:10.1021/ac00047a003 · Cited by 117
Self-citationPickup, J. C., Shaw, G. W., & Claremont, D. J. (1989) · Diabetologia · doi:10.1007/bf00265097 · Cited by 114
Cited by
Sorted by citations
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationPhotopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Barton, S. C., Gallaway, J., & Atanassov, P. B. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,396
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Self-citationFluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Fabrication of Poly(ethylene glycol) Hydrogel Microstructures Using Photolithography
Revzin, A., Russell, R. J., Yadavalli, V. K., Koh, W., Deister, C. A., Hile, D. D., Mellott, M. B., & Pishko, M. V. (2001) · Langmuir · doi:10.1021/la010075w · Cited by 472
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 423
Mellott, M. B., Searcy, K., & Pishko, M. V. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00258-1 · Cited by 392
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Engineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 259
Self-citation3D printing of inherently nanoporous polymers via polymerization-induced phase separation
Dong, Z., Cui, H., Zhang, H., Wang, F., Zhan, X., Mayer, F., Nestler, B., Wegener, M., & Levkin, P. A. (2021) · Nature Communications · doi:10.1038/s41467-020-20498-1 · Cited by 254
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citationOverstreet, D. J., Dutta, D., Stabenfeldt, S. E., & Vernon, B. L. (2012) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.23081 · Cited by 204
In vitro biocompatibility of biodegradable dextran-based hydrogels tested with human fibroblasts
Groot, C. J. D. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00266-0 · Cited by 184
Design of Multiresponsive Hydrogel Particles and Assemblies
Hendrickson, G. R., Smith, M. H., South, A. B., & Lyon, L. A. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200902429 · Cited by 185
Anti-Inflammatory Polymeric Coatings for Implantable Biomaterials and Devices
Bridges, A. W., & Garcı́a, A. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200628 · Cited by 183
Hyun, D. C., Park, M., Park, C., Kim, B., Younan Xia, A., Hur, J. H., Kim, J. M., Park, J. J., & Jeong, U. (2011) · Advanced Materials · doi:10.1002/adma.201100639 · Cited by 179
Polymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 169
Řı́hová, B. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00404-8 · Cited by 161
Degradable dextran hydrogels: controlled release of a model protein from cylinders and microspheres
Franssen, O., Vandervennet, L., Roders, P., & Hennink, W. E. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00074-7 · Cited by 155
Nanocomposites: From Fabrications to Electrochemical Bioapplications
Xiao, Y., & Li, C. M. (2008) · Electroanalysis · doi:10.1002/elan.200704125 · Cited by 153
Implantable chemical sensors for real-time clinical monitoring: progress and challenges
Frost, M. C., & Meyerhoff, M. E. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00371-x · Cited by 148
Reduced acute inflammatory responses to microgel conformal coatings
Bridges, A. W., Singh, N., Burns, K. L., Babensee, J. E., Lyon, L. A., & Garcı́a, A. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.015 · Cited by 134
Design of a subcutaneous implantable biochip for monitoring of glucose and lactate
Guiseppi‐Elie, A., Brahim, S. I., Slaughter, G. E., & Ward, K. R. (2005) · IEEE Sensors Journal · doi:10.1109/jsen.2005.846173 · Cited by 129
Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Self-citationWang, W., Gao, S., & Wang, B. (1999) · Organic Letters · doi:10.1021/ol9908732 · Cited by 124
Approaches Toward Allowing Electroanalytical Devices to be Used in Biological Fluids
Barfidokht, A., & Gooding, J. J. (2014) · Electroanalysis · doi:10.1002/elan.201400097 · Cited by 120
Integrated medical feedback systems for drug delivery
Heller, A. (2005) · AIChE Journal · doi:10.1002/aic.10489 · Cited by 117
Self-citationJhaveri, S. J., McMullen, J. D., Sijbesma, R. P., Tan, L., Zipfel, W. R., & Ober, C. K. (2009) · Chemistry of Materials · doi:10.1021/cm803174e · Cited by 113
Myung, D. J., Koh, W., Bakri, A., Zhang, F., Marshall, A., Ko, J., Noolandi, J., Carrasco, M. R., Cochran, J. R., Frank, C. W., et al. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9040-4 · Cited by 111
Use of hydrogel coating to improve the performance of implanted glucose sensors
Yu, B., Wang, C., Ju, Y. M., West, L., Harmon, J., Moussy, Y., & Moussy, F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.010 · Cited by 105
Immobilization of multi-enzyme microreactors inside microfluidic devices
Koh, W., & Pishko, M. V. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.08.025 · Cited by 103
Scholten, K., & Meng, E. F. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.02.022 · Cited by 106
Sirkar, K., & Pishko, M. V. (1998) · Analytical Chemistry · doi:10.1021/ac971236x · Cited by 102
Building Fluorescent Sensors for Carbohydrates Using Template-Directed Polymerizations
Gao, S. (2001) · Bioorganic Chemistry · doi:10.1006/bioo.2001.1219 · Cited by 101
Polymeric “smart” coatings to prevent foreign body response to implantable biosensors
Wang, Y., Papadimitrakopoulos, F., & Burgess, D. J. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.12.028 · Cited by 100
Mass transfer in rapidly photopolymerized poly(ethylene glycol) hydrogels used for chemical sensing
Russell, R. J., Axel, A. C. S., Shields, K. L., & Pishko, M. V. (2001) · Polymer · doi:10.1016/s0032-3861(00)00851-x · Cited by 100
Seong, G. H., Zhan, W., & Crooks, R. M. (2002) · Analytical Chemistry · doi:10.1021/ac020069k · Cited by 99
Noninvasive and Minimally-Invasive Optical Monitoring Technologies
Coté, G. L. (2001) · Journal of Nutrition · doi:10.1093/jn/131.5.1596s · Cited by 84
Probing the Surface Structural Rearrangement of Hydrogels by Sum-Frequency Generation Spectroscopy
Chen, Q., Zhang, D., Somorjai, G. A., & Bertozzi, C. R. (1998) · Journal of the American Chemical Society · doi:10.1021/ja9831453 · Cited by 77
Fully Integrated Biochip Platforms for Advanced Healthcare
Carrara, S., Ghoreishizadeh, S. S., Olivo, J., Taurino, I., Baj-Rossi, C., Cavallini, A., de Beeck, M. O., Dehollain, C., Burleson, W. P., Moussy, F. G., et al. (2012) · Sensors · doi:10.3390/s120811013 · Cited by 79
Application of Semipermeable Membranes in Glucose Biosensing
Kulkarni, T., & Slaughter, G. E. (2016) · Membranes · doi:10.3390/membranes6040055 · Cited by 76
Gong, H. Y., Park, J., Kim, W., Kim, J., Lee, J. Y., & Koh, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b16005 · Cited by 71
Ju, Y. M., Yu, B., Koob, T. J., Moussy, Y., & Moussy, F. G. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31756 · Cited by 70
Cryogelation for preparation of novel biodegradable tissue-engineering scaffolds
Bölgen, N., Plieva, F. M., Galaev, I. Y., Mattìasson, B., & Pişkın, E. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207781554064 · Cited by 69
Kim, Y. S., Cho, K., Lee, H. J., Chang, S., Lee, H., Kim, J. H., & Koh, W. (2016) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2016.09.003 · Cited by 71
Schmidtke, D. W., & Heller, A. (1998) · Analytical Chemistry · doi:10.1021/ac970932u · Cited by 65
Self-citationHeller, A. (1996) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(96)80094-2 · Cited by 69
Self-citationLee, W., Choi, D., Lee, Y., Kim, D. N., Park, J., & Koh, W. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.09.085 · Cited by 64
Synthesis, characterization and crosslinking of functional star‐shaped poly(ε‐caprolactone)
Turunen, M. P. K., Korhonen, H., Tuominen, J. U., & Seppälä, J. V. (2001) · Polymer International · doi:10.1002/pi.805 · Cited by 66
Liao, Y., Wang, W., & Wang, B. (1999) · Bioorganic Chemistry · doi:10.1006/bioo.1999.1151 · Cited by 62
Lee, H. J., & Koh, W. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501714k · Cited by 61
An, S. Y., Bui, M.-P. N., Nam, Y. J., Han, K. N., Li, C. A., Choo, J., Lee, E. K., Katoh, S., Kumada, Y., & Seong, G. H. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.11.022 · Cited by 60
Basics of DNA biosensors and cancer diagnosis
Sohrabi, N., Valizadeh, A., Farkhani, S. M., & Akbarzadeh, A. (2014) · Artificial Cells Nanomedicine and Biotechnology · doi:10.3109/21691401.2014.976707 · Cited by 60
Enzyme Containing Redox Polymer Networks for Biosensors or Biofuel Cells: A Photochemical Approach
Bunte, C., Prucker, O., König, T. A. F., & Rühe, J. (2009) · Langmuir · doi:10.1021/la9037183 · Cited by 59
Matharu, Z., Enomoto, J., & Revzin, A. (2012) · Analytical Chemistry · doi:10.1021/ac3025619 · Cited by 57
Noninvasive glucose detection in exhaled breath condensate
Tankasala, D., & Linnes, J. C. (2019) · Translational research · doi:10.1016/j.trsl.2019.05.006 · Cited by 54
Singh, D., Tripathi, A., Nayak, V., & Kumar, A. (2011) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/092050610x522486 · Cited by 53
The Fibrotic Response to Implanted Biomaterials: Implications for Tissue Engineering
Rolfe, B. E., Mooney, J. E., Zhang, B., Jahnke, S., Le, S.-J., Chau, Y.-Q., Huang, Q., Wang, H., CAMPBELL, G. R., & Campbell, J. (2011) · InTech eBooks · doi:10.5772/21790 · Cited by 59
Ju, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32400 · Cited by 52
Micropatterned Nanocomposite Hydrogels for Biosensing Applications
Pedrosa, V. A., Yan, J., Simonian, A. L., & Revzin, A. (2011) · Electroanalysis · doi:10.1002/elan.201000654 · Cited by 51
Chronic inflammatory responses to microgel‐based implant coatings
Bridges, A. W., Whitmire, R. E., Singh, N., Templeman, K. L., Babensee, J. E., Lyon, L. A., & Garcı́a, A. J. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32669 · Cited by 52
Wagner, J. G., Schmidtke, D. W., Quinn, C. P., Fleming, T. F., Bernacky, B. J., & Heller, A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.11.6379 · Cited by 51
Self-citationZhang, W., Zhang, Z., & Wang, X. (2009) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.01.058 · Cited by 50
Tissue responses to novel tissue engineering biodegradable cryogel scaffolds: An animal model
Bölgen, N., Vargel, İ., Korkusuz, P., Güzel, E., Plieva, F. M., Galaev, I. Y., Mattìasson, B., & Pişkın, E. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32193 · Cited by 50
Catalase Effects on Glucose-Sensitive Hydrogels
Jung, D.-Y., Magda, J. J., & Han, I. S. (2000) · Macromolecules · doi:10.1021/ma992098b · Cited by 50
Papadopoulos, A., Bichara, D. A., Zhao, X., Ibusuki, S., Randolph, M. A., Anseth, K. S., & Yaremchuk, M. J. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0253 · Cited by 46
Indispensable Platforms for Bioimmobilization: Maleimide-Based Thiol Reactive Hydrogels
Park, E. J., Gevrek, T. N., Sanyal, R., & Sanyal, A. (2014) · Bioconjugate Chemistry · doi:10.1021/bc500375r · Cited by 46
Titanium surface modification techniques for dental implants—From microscale to nanoscale
Subramani, K., Mathew, R. T., & Pachauri, P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-812291-4.00006-6 · Cited by 46
Bölgen, N., Yang, Y., Korkusuz, P., Güzel, E., Haj, A. J. E., & Piskin, E. (2010) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.375 · Cited by 44
Sources of instability of ‘wired’ enzyme anodes in serum: urate and transition metal ions
Binyamin, G. N., Chen, T., & Heller, A. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00267-9 · Cited by 44
Self-citationBiointerface analysis on a molecular level
Tiefenauer, L., & Ros, R. (2002) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(01)00228-4 · Cited by 42
Lee, W., Choi, D., Kim, J. H., & Koh, W. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9196-1 · Cited by 41
Application of responsive polymers in implantable medical devices and biosensors
Li, J., Stachowski, M., & Zhang, Z. (2015) · Elsevier eBooks · doi:10.1016/b978-0-85709-713-2.00011-0 · Cited by 41
Electrochemical biosensors for on-chip detection of oxidative stress from immune cells
Yan, J., Pedrosa, V. A., Enomoto, J., Simonian, A. L., & Revzin, A. (2011) · Biomicrofluidics · doi:10.1063/1.3624739 · Cited by 40
Characterization of Biomaterials by Soft X-Ray Spectromicroscopy
Leung, B. O., Brash, J. L., & Hitchcock, A. P. (2010) · Materials · doi:10.3390/ma3073911 · Cited by 39
Recent Advances in Anti-inflammatory Strategies for Implantable Biosensors and Medical Implants
Lee, D., Park, K., & Seo, J. (2020) · BioChip Journal · doi:10.1007/s13206-020-4105-7 · Cited by 38
Quinn, C. P., Pishko, M. V., Schmidtke, D. W., Ishikawa, M., Wagner, J. G., Raskin, P., Hubbell, J. A., & Heller, A. (1995) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1995.269.1.e155 · Cited by 38
Self-citationJang, E., Park, S., Park, S., Lee, Y., Kim, D., Kim, B., & Koh, W. (2009) · Polymers for Advanced Technologies · doi:10.1002/pat.1455 · Cited by 37
Buckling‐Assisted Patterning of Multiple Polymers
Hyun, D. C., Moon, G. D., Park, C. J., Kim, B. S., Younan Xia, A., & Jeong, U. (2010) · Advanced Materials · doi:10.1002/adma.201000277 · Cited by 37
Anti‐inflammatory properties of micropatterned titanium coatings
Sahlin, H., Contreras, R., Gaskill, D. F., Bjursten, L. M., & Frangos, J. A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30642 · Cited by 36
Park, S., Nam, S. H., & Koh, W. (2011) · Journal of Applied Polymer Science · doi:10.1002/app.34532 · Cited by 35
Lee, Y., Kim, D. N., Choi, D., Lee, W., Park, J., & Koh, W. (2008) · Polymers for Advanced Technologies · doi:10.1002/pat.1047 · Cited by 35
Distributed sensor and actuator networks for closed-loop bioelectronic medicine
Bhave, G., Chen, J., Singer, A. L., Sharma, A., & Robinson, J. T. (2021) · Materials Today · doi:10.1016/j.mattod.2020.12.020 · Cited by 34
Yavuz, H., Bayramoğlu, G., Kaçar, Y., Deni̇zli̇, A., & Arica, M. Y. (2002) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(01)00146-2 · Cited by 34
Kolewe, K. W., Kalasin, S., Shave, M. K., Schiffman, J. D., & Santore, M. M. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b18302 · Cited by 33
Lasagni, A. F., Yuan, D., Shao, P., & Das, S. (2009) · Advanced Engineering Materials · doi:10.1002/adem.200800295 · Cited by 33
Bölgen, N., Korkusuz, P., Vargel, İ., Kılıç, E., Güzel, E., Çavuşoğlu, T., Uçkan, D., & Pişkın, E. (2013) · Artificial Cells Nanomedicine and Biotechnology · doi:10.3109/21691401.2013.775578 · Cited by 33
Czuba, U., Quintana, R., Pauw‐Gillet, M. D., Bourguignon, M., Moreno‐Couranjou, M., Alexandre, M., Detrembleur, C., & Choquet, P. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701059 · Cited by 30
Material Design in Implantable Biosensors toward Future Personalized Diagnostics and Treatments
Ghorbanizamani, F., Moulahoum, H., Guler, E., & Tımur, S. (2023) · Applied Sciences · doi:10.3390/app13074630 · Cited by 33
Characteristics of Two Self-Powered Glucose Biosensors
Kulkarni, T., & Slaughter, G. E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2696260 · Cited by 29
Titanium Surface Modification Techniques for Dental Implants—From Microscale to Nanoscale
Subramani, K., & Mathew, R. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-7862-1.00006-7 · Cited by 28
Statistics for Critical Clinical Decision Making Based on Readings of Pairs of Implanted Sensors
Schmidtke, D. W., Pishko, M. V., Quinn, C. P., & Heller, A. (1996) · Analytical Chemistry · doi:10.1021/ac9602027 · Cited by 27
Self-citationRussell, R. J., Sirkar, K., & Pishko, M. V. (2000) · Langmuir · doi:10.1021/la991388i · Cited by 26
Subramani, K., & Birch, M. A. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/3/009 · Cited by 25
Photoresponsive smart template for reversible cell micropatterning
Gong, Y., Yang, J., Cao, F., Zhang, J., Cheng, H. L., Zhuo, R., & Zhang, X. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20073f · Cited by 25
Metadata
- Authors
- Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A.
- Affiliations
- The University of Texas at Austin (US)
- Corresponding author
- Hubbell, Jeffrey A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 16
- Issue
- 5
- Pages
- 389-396
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1988024774
- Cited by
- 172
- References
- 19
- Citations by year
- 2025: 5 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 4 · 2014: 8 · 2013: 8 · 2012: 7
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- National Institutes of Health (5r01dk042015-07)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK42015)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- 2-hydroxyethyl methacrylate, ethylene glycol dimethacrylate, glucose biosensor, biocompatibility, subcutaneous implantation, glucose oxidase, gold electrode, fibrous encapsulation, in situ crosslinking, 2,2-dimethoxy-2-phenylacetophenone
- MeSH terms
- Acrylates, Animals, Biocompatible Materials, Calibration, Cross-Linking Reagents, Glucose, Male, Methacrylates, Photochemistry, Polyethylene Glycols, Polymers, Ultraviolet Rays, Biosensing Techniques, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›