Measurements of Young's modulus of elasticity of the canine aorta with ultrasound
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ostle, B. (1969) · Cited by 1,089
The dynamic elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006687 · Cited by 904 · cited 1×
“Bergel [9] found that the dynamic modulus was independent of distending frequency for frequencies greater than 2 Hz and less than 10 Hz.”
BackgroundThe static elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006686 · Cited by 661 · cited 3×
“Bergel [9] found that the dynamic modulus was independent of distending frequency for frequencies greater than 2 Hz and less than 10 Hz.”
BackgroundIntroduction to the Theory of Statistics.
Welch, B. L., Mood, A. M., & Graybill, F. A. (1964) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982296 · Cited by 476
The Elastic Symmetry of Arterial Segments in Dogs
PATEL, D. J., FRY, D. L., & Janicki, J. S. (1969) · Circulation Research · doi:10.1161/01.res.24.1.1 · Cited by 411 · cited 1×
“[5], measures the velocity at which the upstroke of the blood pressure waveform travels.”
BackgroundUeber die Fortpflanzungsgeschwindigkeit des Schalles in elastischen Röhren
Korteweg, D. J. (1878) · Annalen der Physik · doi:10.1002/andp.18782411206 · Cited by 373
Measurement of Viscoelastic Properties of Arteries in the Living Dog
GOW, B. S., & TAYLOR, M. G. (1968) · Circulation Research · doi:10.1161/01.res.23.1.111 · Cited by 209
Static Anisotropic Elastic Properties of the Aorta in Living Dogs
Patel, D. J., Janicki, J. S., & Carew, T. E. (1969) · Circulation Research · doi:10.1161/01.res.25.6.765 · Cited by 178 · cited 1×
“Others have described the nonlinear elastic behavior of blood vessels [6, 8, 10, 12-14].”
BackgroundPressure-Volume Relation for Cylindrical Tubes with Elastomeric Walls: The Human Aorta
King, A. L. (1946) · Journal of Applied Physics · doi:10.1063/1.1707745 · Cited by 39
Ultrasonic transit-time system for arterial diameter measurement
Bertram, C. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442276 · Cited by 31
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement
Luo, N., Dai, W., Li, C., Zhou, Z., Lu, L., Poon, C. C. Y., Chen, S., Zhang, Y., & Zhao, N. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504560 · Cited by 467
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time
Poon, C. C. Y., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615827 · Cited by 375
Ding, X.-R., Zhang, Y.-T., Liu, J., Dai, W.-X., & Tsang, H. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2480679 · Cited by 330
Relation between blood pressure and pulse wave velocity for human arteries
Ma, Y., Choi, J., Hourlier-Fargette, A., Xue, Y., Chung, H. U., Lee, J. Y., Wang, X., Xie, Z., Kang, D., Wang, H., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814392115 · Cited by 309
Xu, H., Liu, J., Zhang, J., Zhou, G., Luo, N., & Zhao, N. (2017) · Advanced Materials · doi:10.1002/adma.201700975 · Cited by 298
Wearable Pressure Sensors Based on MXene/Tissue Papers for Wireless Human Health Monitoring
Yang, L., Wang, H., Yuan, W., Li, Y., Gao, P., Tiwari, N., Chen, X., Wang, Z., Niu, G., & Cheng, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22001 · Cited by 283
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 265
Recent Progress of Flexible Image Sensors for Biomedical Applications
Yokota, T., Fukuda, K., & Someya, T. (2021) · Advanced Materials · doi:10.1002/adma.202004416 · Cited by 229
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Wong, M. Y.-M., Poon, C. C.-Y., & Zhang, Y.-T. (2009) · Cardiovascular Engineering · doi:10.1007/s10558-009-9070-7 · Cited by 191
Tanveer, M. S., & Hasan, M. K. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.028 · Cited by 188
An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
Zheng, Y.-L., Yan, B. P., Zhang, Y.-T., & Poon, C. C. Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2318779 · Cited by 177
A Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691715 · Cited by 174
The effect of local mild cold exposure on pulse transit time
Zhang, X.-Y., & Zhang, Y.-T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/008 · Cited by 40
Metadata
- Authors
- Hughes, D.
- Venue
- Ultrasonic Imaging
- Publisher
- Elsevier BV
- Published
- 1979-10
- Volume
- 1
- Issue
- 4
- Pages
- 356-367
- ISSN
- 0161-7346 (ISSN-L)
- OpenAlex
- W1966556266
- Cited by
- 189
- References
- 12
- FWCI
- 0.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.