Methods of isfet fabrication
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We cannot signify the body effects in the SG operation, because the sensitivity of devices is in a similar distribution from 39.82 mV/pH to 47.19 mV/pH (Figure S3), within the reported sensitivity of 25 to 48 mV/pH25.”
From Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body (2014) · cites this paper as [25]
Citations
Cites
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
A Water-Amine-Complexing Agent System for Etching Silicon
Finne, R. M., & Klein, D. L. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426793 · Cited by 309
Potassium ion-sensitive field effect transistor
Moss, S. D., Janata, J., & Johnson, C. C. (1975) · Analytical Chemistry · doi:10.1021/ac60363a005 · Cited by 237
An Integrated Field-Effect Electrode for Biopotential Recording
Matsuo, T., & Wise, K. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324338 · Cited by 235
Self-citationIntegrated Micro Multi Ion Sensor Using Field Effect of Semiconductor
Esashi, M., & Matsuo, T. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326245 · Cited by 198
Self-citationAboaf, J. A. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426787 · Cited by 143
Selected Properties of Pyrolytic Ta[sub 2]O[sub 5] Films
Knausenberger, W. H., & Tauber, R. N. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403602 · Cited by 89
Applications of Immobilized Enzymes in Analytical Chemistry
Bowers, L. D., & Carr, P. W. (1976) · Analytical Chemistry · doi:10.1021/ac60371a033 · Cited by 74
Field effect potentiometric sensors
Buck, R. P., Hackleman, D. E., & Kenan, W. R. (1977) · Analytical Chemistry · doi:10.1021/ac50022a051 · Cited by 63
Properties of Vapor-Deposited Aluminum Arsenide
Sigai, A. G., Abrahams, M. S., & Blanc, J. (1972) · Journal of The Electrochemical Society · doi:10.1149/1.2404375 · Cited by 16
Research works printed but not linked: 4
- Abe, 1979, ISFETs using inorganic gate this films, IEEE trans. Electroc Devices, ED-26, 1939, 1944
- Tarui, 1969, Si MOS characteristics using vapor grown Al2O3 films, Rep. Electro. Tech. Lab. Jpn., 33, 578
- Comte, 1977, Reference ISFET for compensation, Proc. 30th ACEMB, 41-3
- Matsuo, 1978, Charasteristics of Parylene Gate ISFET, Extended Abstr. 153rd Meetings, ECS, Vol. 78-1, No. 83, Seattle
Cited by
Items 101–200 of 349
ISFET performance enhancement by using the improved circuit techniques
Chung, W., Yang, C.-H., Pijanowska, D. G., Grabiec, P., & Torbicz, W. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.06.018 · Cited by 40
“V (1) − V (S) = |Vref| (2) The bridge-type ISFET interface circuit responds to the ion concentration of the solution due to the feedback loop operation of the amplifier and constant value floating reference voltage supplied.”
BackgroundIonic detection using differential measurement between an ion-sensitive FET and a reference FET
Perrot, H., Jaffrezic-Renault, N. J., de Rooij, N. F., & van den Vlekkert, H. H. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)80128-3 · Cited by 34
Polyvinylbutyral resin membrane for enzyme immobilization to an isfet microbiosensor
Gotoh, M., Tamiya, E., & Karube, I. (1986) · Journal of Molecular Catalysis · doi:10.1016/0304-5102(86)85002-7 · Cited by 34
Chou, J.-C., Chiang, J.-L., & Wu, C.-L. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.4838 · Cited by 33
CMOS-compatible biosensor for L-carnitine detection
Andrianova, M. S., Kuznetsov, E. V., Grudtsov, V. P., & Kuznetsov, A. E. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.044 · Cited by 32
ZrO2 gate pH-sensitive field effect transistor
Sobczyńska, D., & Torbicz, W. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)85002-7 · Cited by 32
Low drift and small hysteresis characteristics of diamond electrolyte-solution-gate FET
Sasaki, Y., & Kawarada, H. (2010) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/43/37/374020 · Cited by 34
Olthuis, W., Luo, J., van der Schoot, B. H., Bergveld, P., Bos, M. J., & van der Linden, W. E. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85111-9 · Cited by 31
Multilayer ISFET membranes for microsystems applications
Cane, C., Götz, A., Merlos, Á., Gràcia, I., Errachid, A., Losantos, P., & Lora‐Tamayo, E. (1996) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)80043-3 · Cited by 31
Plasma-Polymerized Thin Films for Enzyme Immobilization in Biosensors
Kampfrath, G., & Hintsche, R. (1989) · Analytical Letters · doi:10.1080/00032718908052364 · Cited by 31
pH Sensitivity of SiC Linked Organic Monolayers on Crystalline Silicon Surfaces
Faber, E. J., Sparreboom, W., Groeneveld, W. H., de Smet, L. C. P. M., Bomer, J. G., Olthuis, W., Zuilhof, H. T., Sudhölter, E. J. R., Bergveld, P., & van den Berg, A. (2006) · ChemPhysChem · doi:10.1002/cphc.200600447 · Cited by 30
Pan, T.-M., & Lin, C.-W. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp107733u · Cited by 33
Ma, S., Lee, Y.-K., Zhang, A., & Li, X. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.02.148 · Cited by 31
Shen, S.-H., Wang, I.-S., Cheng, H., & Lin, C. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.05.002 · Cited by 30
Monitoring of ISFET encapsulation aging by impedance measurements
Chovelon, J., Jaffrezic-Renault, N. J., Cros, Y., Fombon, J. J., & Pedone, D. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)85006-5 · Cited by 30
Gubanova, O. V., Andrianova, M. S., Saveliev, M., Komarova, N. V., Kuznetsov, E. V., & Kuznetsov, A. E. (2016) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2016.12.007 · Cited by 29
Suzurikawa, J., Nakao, M., Jimbo, Y., Kanzaki, R., & Takahashi, H. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.10.139 · Cited by 31
Temperature effect of a-Si:H pH-ISFET
Chou, J.-C., Wang, Y.-F., & Lin, J.-S. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00369-x · Cited by 29
Micro-fet biosensors using polyvinylbutyral membrane
Gotoh, M., Tamiya, E., & Karube, I. (1989) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)82409-6 · Cited by 29
Thickness Effects on pH Response of HfO2 Sensing Dielectric Improved by Rapid Thermal Annealing
Lai, C., Yang, C., & Lu, T.-F. (2006) · Japanese Journal of Applied Physics · doi:10.1143/jjap.45.3807 · Cited by 30
Kimura, J., & Kuriyama, T. (1990) · Journal of Biotechnology · doi:10.1016/0168-1656(90)90030-f · Cited by 27
Study on the Time-Dependent Slow Response of the Tin Oxide pH Electrode
Tsai, C.-N., Chou, J.-C., Sun, T. P., & Hsiung, S.-K. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.881364 · Cited by 28
“According to Matsuo and Esashi [14], the loop circle of the sequence of pH values was employed on the measurement of the hysteresis width.”
BackgroundMethodInfluentialHuang, Y. L., Caneiro, A., Attari, M., & Fabry, P. (1991) · Thin Solid Films · doi:10.1016/0040-6090(91)90372-5 · Cited by 26
Ion-sensitive membranes fabricated by the ion-beam technique
Pham, M. T., & Hoffmann, W. E. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80012-8 · Cited by 26
Andrianova, M. S., Gubanova, O. V., Komarova, N. V., Kuznetsov, E. V., & Kuznetsov, A. E. (2016) · Electroanalysis · doi:10.1002/elan.201500411 · Cited by 27
Simulation and Experimental Study of the pH-Sensing Property for AlN Thin Films
Chiang, J.-L., Chen, Y., & Chou, J.-C. (2001) · Japanese Journal of Applied Physics · doi:10.1143/jjap.40.5900 · Cited by 30
pH, pK and pNa detection properties of SiO2/Si3N4 ISFET chemical sensors
Hajji, B., Temple‐Boyer, P., Launay, J., Conto, T. D., & Martínez, A. (2000) · Microelectronics Reliability · doi:10.1016/s0026-2714(99)00285-1 · Cited by 25
Pan, T.-M., & Huang, M.-D. (2011) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2011.05.032 · Cited by 25
Towards fast solid state DNA sequencing
Purushothaman, S., Toumazou, C., & Georgiou, J. (2003) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2002.1010416 · Cited by 24
“The passivation is also modified to ensure protection from hydration and charge migration. [ 4 ]”
BackgroundBriand, D., Mondin, G., Jenny, S., van der Wal, P. D., Jeanneret, S., de Rooij, N. F., Banakh, O., & Keppner, H. (2005) · Thin Solid Films · doi:10.1016/j.tsf.2005.03.021 · Cited by 24
ISFET's with ion-sensitive membranes fabricated by ion implantation
Tsugue, I. T. O., Inagaki, H., & Igarashi, I. (1988) · IEEE Transactions on Electron Devices · doi:10.1109/16.2415 · Cited by 24
Pachauri, V., Kern, K., & Balasubramanian, K. (2013) · Applied Physics Letters · doi:10.1063/1.4775579 · Cited by 24
ImmunoFET feasibility in physiological salt environments
Casal, P., Wen, X., Gupta, S. K., Nicholson, T. R., Wang, Y., Theiss, A., Bhushan, B., Brillson, L. J., Lu, W., & Lee, S. C. (2012) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0503 · Cited by 23
Anzai, J., Lee, S., & Osa, T. (1989) · Die Makromolekulare Chemie Rapid Communications · doi:10.1002/marc.1989.030100404 · Cited by 23
Alegret, S., Bartrolí, J., Jiménez‐Jorquera, C., del Valle, M., Domínguez, C., Cabruja, E., & Merlos, Á. (1991) · Electroanalysis · doi:10.1002/elan.1140030418 · Cited by 23
Jaffrezic-Renault, N. J., De, A., Cléchet, P., & Maaref, A. (1989) · Colloids and Surfaces · doi:10.1016/0166-6622(89)80095-2 · Cited by 23
Polyurethane Enzyme Membranes for Chip Biosensors
Hintsche, R., Neumann, G., Dransfeld, I., Kampfrath, G., Hoffmann, B., & Scheller, F. W. (1989) · Analytical Letters · doi:10.1080/00032718908051246 · Cited by 23
A physically-based model for drift in Al/sub 2/O/sub 3/-gate pH ISFET's
Jamasb, S., Collins, S. D., & Smith, R. L. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.635494 · Cited by 22
Potentiometric responses of ion-selective microelectrode with bovine serum albumin adsorption
Goda, T., Yamada, E., Katayama, Y., Tabata, M., Matsumoto, A., & Miyahara, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.023 · Cited by 24
“Alternatively, ion-sensitive field-effect transistor (ISFET) has been used for measuring the concentration of proton or other ions in potentiometry (Bergveld, 2003; Matsuo and Esashi, 1981).”
MethodMembranes for chemical sensors
Cléchet, P. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)80177-l · Cited by 22
Practical limits for solid-state reference electrodes
Collins, S. D. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)87002-7 · Cited by 21
Application of P450s for biosensing: combination of biotechnology and electrochemistry
Hara, M. (2000) · Materials Science and Engineering C · doi:10.1016/s0928-4931(00)00166-1 · Cited by 21
Comparison of label-free ACh-imaging sensors based on CCD and LAPS
Werner, C. F., Takenaga, S., Taki, H., Sawada, K., & Schöning, M. J. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.11.012 · Cited by 20
Comprehensive Analytical Modelling of an Absolute pH Sensor
Medina-Bailón, C., Kumar, N., Dhar, R. P. S., Todorova, I., Lenoble, D., Georgiev, V., & García, C. P. (2021) · Sensors · doi:10.3390/s21155190 · Cited by 20
Sensitivity of CuS Membrane pH Sensor With and Without MOSFET
Sabah, F. A., Ahmed, N. M., Hassan, Z., Almessiere, M. A., & Al-Hardan, N. H. (2016) · JOM · doi:10.1007/s11837-016-2165-x · Cited by 19
Charge Accumulation Type Hydrogen Ion Image Sensor with High pH Resolution
Takenaga, S., Tamai, Y., Ishida, M., & Sawada, K. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.027001 · Cited by 19
High-Sensitivity Charge-Transfer-Type pH Sensor With Quasi-Signal Removal Structure
Nakazawa, H., Otake, R., Futagawa, M., Dasai, F., Ishida, M., & Sawada, K. (2014) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2013.2292563 · Cited by 19
“Typical materials used the ion selective membrane are SiO2 (silicon dioxide), Si3N4 (silicon nitride), Al2O3 (aluminum oxide), and Ta2O5 (tantalum oxide) [14]–[19].”
BackgroundThe role of the MOS structure in integrated sensors
Senturia, S. D. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85063-x · Cited by 19
Stability of MOSFET-Based Electronic Components in Wearable and Implantable Systems
Jin, X., Jiang, C., Song, E., Fang, H., Rogers, J. A., & Alam, M. A. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2715837 · Cited by 18
“1) Chemical biosensors such as classical Ion-Sensitive Field-Effect Transistor (ISFET) potentiometric sensor [15], [16].”
BackgroundDynamic behaviour of ISFET-based sensor-actuator systems
Olthuis, W., Luo, J., van der Schoot, B. H., Bomer, J. G., & Bergveld, P. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80241-q · Cited by 18
A self-contained CMOS integrated pH sensor
Wong, H. ‐. P., & White, M. H. (2003) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.1988.32899 · Cited by 18
Dutta, J. C., Thakur, H. R., & Keshwani, G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2904517 · Cited by 21
“charged electrolyte ions into the hydrated layer of the sensing membrane (insulator) as it causes a decrease in the effective gate oxide thickness [30], [31].”
BackgroundCharacteristics of Zirconium Oxide Gate Ion-Sensitive Field-Effect Transistors
Chang, K., Chao, K.-Y., Chou, T.-W., & Chang, C.-T. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.4333 · Cited by 18
Sakai, H., Kaneki, N., Hara, H., & Ito, K. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82780-4 · Cited by 18
Urushi matrix sodium, potassium, calcium and chloride-selective field-effect transistors
Wakida, S., Yamane, M., HIGASHI, K., HIIRO, K., & Ujihira, Y. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80240-z · Cited by 18
Reduced Drift of CMOS ISFET pH Sensors Using Graphene Sheets
Panteli, C., Georgiou, P., & Fobelets, K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3074748 · Cited by 20
Kao, C. H., Chen, H., & Huang, C.-Y. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.09.080 · Cited by 17
Gotoh, M., Suzuki, M., Kubo, I., Tamiya, E., & Karube, I. (1989) · Journal of Molecular Catalysis · doi:10.1016/0304-5102(89)80063-x · Cited by 17
Jan, S.-S., Chen, Y., & Chou, J.-C. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.033 · Cited by 18
Temperature Characteristics of a-Si:H Gate ISFET
Chou, J. C., & Wang, Y. F. (2001) · Materials Chemistry and Physics · doi:10.1016/s0254-0584(00)00469-7 · Cited by 17
Amorphous boron carbon nitride as a pH sensor
Li, C. L., Huang, B., Chattopadhyay, S., Chen, K., & Chen, L. (2004) · Applied Physics Letters · doi:10.1063/1.1691195 · Cited by 17
Solid-State Glucose Sensor Using LaF3-Based Transducer
Miura, N., Matayoshi, N., & Yamazoe, N. (1989) · Japanese Journal of Applied Physics · doi:10.1143/jjap.28.l1480 · Cited by 17
Dastidar, S., Agarwal, A., Kumar, N. C., Bal, V., & Panda, S. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2369739 · Cited by 16
“Use of different dielectric materials have been investigated as the most common dielectric material, silicon dioxide, has provided low pH sensitivities (25 − 48 mV/pH) [5].”
BackgroundResultTi-doped Gd2O3 sensing membrane for electrolyte–insulator–semiconductor pH sensor
Kao, C. H., Wang, J., Lai, C., Huang, C. Y., Ou, J. C., & Wang, H. Y. (2011) · Thin Solid Films · doi:10.1016/j.tsf.2011.11.063 · Cited by 16
Drop-Coated Polyaniline Composite Conductimetric pH Sensors
Arshak, A., Gill, E., Arshak, K. I., Korostynska, O., & Cunniffe, C. (2007) · International Spring Seminar on Electronics Technology · doi:10.1109/isse.2007.4432850 · Cited by 16
“One such disadvantage was the drift of the device response over time [3], which also exposed a second drawback of the poor sensitivity of the devices [4].”
BackgroundAlcohol-FET sensor based on a complex cell membrane enzyme system
Tamiya, E., Karube, I., Kitagawa, Y., Ameyama, M., & Nakashima, K. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80784-9 · Cited by 16
Takechi, K., Iwamatsu, S., Konno, S., Yahagi, T., Yutaka, A. B. E., Katoh, M., & Tanabe, H. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.078004 · Cited by 17
Sinha, S., Pal, T., Sharma, P., Kharbanda, D. K., Khanna, P. K., Tanwar, A., Sharma, R., & Mukhiya, R. (2021) · Journal of Electronic Materials · doi:10.1007/s11664-021-09220-z · Cited by 16
Simulation of time-dependent effects of pH-ISFETs
Chou, J. C., Huang, K. Y., & Lin, J. S. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00361-5 · Cited by 16
Field‐Effect transistors as transducers in biosensors for substrates of dehydrogenases
Vering, T., Schuhmann, W. W., Schmidt, H., Mikolajick, T., Falter, T., Ryssel, H., & Janata, J. (1994) · Electroanalysis · doi:10.1002/elan.1140061106 · Cited by 15
Riedel, V., Hinck, S., Peiter, E., & Ruckelshausen, A. (2024) · Electronics · doi:10.3390/electronics13132449 · Cited by 18
“The operational point of the ISFET is typically provided by the manufacturer and can be modi fi ed during the manufacturing process, and subsequently during operation, contingent on the speci fi c requirements of the application [23].”
BackgroundHigh performance flexible pH sensor based on carboxyl-functionalized and DEP aligned SWNTs
Liu, L., Shao, J., Li, X., Zhao, Q., Nie, B., Xu, C., & Ding, H. (2016) · Applied Surface Science · doi:10.1016/j.apsusc.2016.06.058 · Cited by 16
Size Independent pH Sensitivity for Ion Sensitive FinFETs Down to 10 nm Width
Gupta, M., Santermans, S., Veloso, A., Tao, Z., Li, W., Hellings, G., Lagae, L., Roy, W. V., & Martens, K. M. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2912503 · Cited by 14
“The key role of a large intrinsic buffer capacity is to accommodate the additional electrical charge (by protonation/deprotonation of the surface groups), to support the additional potential drop over the double layer, with as small as possible change in surface pH. Oxides like HfO2 [12], Ta2O5 [21] and Al2O3 [22], ex…”
BackgroundInfluentialChen, Y., Jan, S.-S., & Chou, J.-C. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.03.078 · Cited by 14
Creation of highly functional thin films using electrochemical nanotechnology
Ōsaka, T. (2004) · The Chemical Record · doi:10.1002/tcr.20025 · Cited by 14
High gain ISFET based νMOS chemical inverter
Alahdal, A., & Toumazou, C. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.067 · Cited by 14
Lee, T. N., Chen, H. J. H., & Hsieh, K. C. (2016) · IEEE Electron Device Letters · doi:10.1109/led.2016.2619714 · Cited by 15
“Compared to the enzyme electrodes, ISFETs are smaller in size, have a shorter response time, and can be also integrated into a micro array incorporated with different sensing membranes for the simultaneous detection of multiple bioagents [2].”
BackgroundHigh-density silicon nitride thin film in PECVD
Reynes, B., & Bruyere, J.-C. (1992) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(92)80003-l · Cited by 13
Jan, S.-S., Chiang, J.-L., Chen, Y., Chou, J.-C., & Cheng, C.-C. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00722-5 · Cited by 13
Method of fabrication of ISFETs and CHEMFETs on an Si-SiO2-Si structure
Poghossian, A. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)85130-3 · Cited by 13
Instrumentation in the food industry. I. Chemical, biochemical and immunological determinands
Kress-Rogers, E. (1986) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/19/1/001 · Cited by 13
New type biosensor using solid electrolyte
Matayoshi, N., Miura, N., & Yamazoe, N. (1990) · Solid State Ionics · doi:10.1016/0167-2738(90)90374-z · Cited by 13
Rochefeuille, S., Jiménez‐Jorquera, C., Tingry, S., Patrick, S. E. T. A., & Desfours, J. P. (2002) · Materials Science and Engineering C · doi:10.1016/s0928-4931(02)00056-5 · Cited by 12
Alahdal, A., & Toumazou, C. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2163185 · Cited by 12
“It is known that ISFETs built by CMOS technology suffer from reduced sensitivity [4]–[6].”
BackgroundUltrahigh-Sensitive CMOS pH Sensor Developed in the BEOL of Standard 28 nm UTBB FDSOI
Ayele, G. T., Monfray, S., Ecoffey, S., Bœuf, F., Cloarec, J., Drouin, D., & Souifi, A. (2018) · IEEE Journal of the Electron Devices Society · doi:10.1109/jeds.2018.2861622 · Cited by 14
“However, the sensor can be operated in wider pH range as both the sensing film and the transistor have wide linear operating ranges [10], [18].”
BackgroundBae, T.-E., Jang, H., Lee, S., & Cho, W.-J. (2013) · Japanese Journal of Applied Physics · doi:10.7567/jjap.52.06gk03 · Cited by 12
Influence of the degradation on the surface states and electrical characteristics of EOS structures
Cabruja, E., Merlos, Á., Cane, C., Lozano, M., Bausells, J., & Estéve, J. (1991) · Surface Science · doi:10.1016/0039-6028(91)91015-p · Cited by 12
CMOS ISFET-based structures for biomedical applications
Palan, B., Roubik, K., Hušák, M., & Courtois, B. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893835 · Cited by 12
A classification of chemically sensitive semiconductor devices
Saaman, A. A., & Bergveld, P. (1985) · Sensors and Actuators · doi:10.1016/0250-6874(85)85010-1 · Cited by 12
An extended model of the electrolyte/hydrogen ion-sensitive field-effect transistor system
Torbicz, W., & Sypniewska, Z. (1992) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(92)80365-5 · Cited by 12
Microbiosensor Based on Silicon Fabrication Technology
Karube, I., Tamiya, E., Murakami, T., Gotoh, M., & Kagawa, Y. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb45718.x · Cited by 12
Comparison of the pH sensitivity of different surfaces on tantalum pentoxide
Chou, J.-C., & Hsiao, C. N. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00446-3 · Cited by 11
Indium tin oxide coated PET for differential pH‐sensing using field‐effect transistor based sensor
Mokhtarifar, N., Goldschmidtboeing, F., & Woias, P. (2018) · Micro & Nano Letters · doi:10.1049/mnl.2018.5240 · Cited by 11
Shin, P.-K., & Mikolajick, T. (2003) · Applied Surface Science · doi:10.1016/s0169-4332(02)01527-1 · Cited by 11
Alkali- and hydrogen ion sensing properties of LPCVD silicon oxynitride thin films
Shin, P.-K., & Mikolajick, T. (2003) · Thin Solid Films · doi:10.1016/s0040-6090(03)00041-5 · Cited by 11
Semiconductor surface device physics
ZEMEL, J. N. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80005-4 · Cited by 11
A Review of Implantable Sensors
Ko, W. H. (1983) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1983.tb04395.x · Cited by 11
High-Performance Electrolyte–Insulator–Semiconductor pH Sensors Using High-$k$ CeO2 Sensing Films
Pan, T.-M., Wang, C., & Pan, S.-Y. (2015) · IEEE Electron Device Letters · doi:10.1109/led.2015.2475627 · Cited by 10
“However, the Si3N4 sensing membrane has some drawbacks such as hysteresis and drift effects, that lower the accuracy of these sensors [3].”
BackgroundIon image sensors and their application for visualization of neural activity
Sawada, K., & 服部, 敏. (2018) · Japanese Journal of Applied Physics · doi:10.7567/jjap.57.1002a2 · Cited by 10
Wakida, S., Kohigashi, Y., Miyamura, H., HIGASHI, K., & Ujihira, Y. (1996) · Analytical Sciences · doi:10.2116/analsci.12.989 · Cited by 10
Metadata
- Authors
- Matsuo, T., & Esashi, M.
- Affiliations
- Tohoku University (JP)
- Venue
- Sensors and Actuators
- Publisher
- Elsevier BV
- Published
- 1981-01
- Volume
- 1
- Pages
- 77-96
- ISSN
- 0250-6874 (ISSN-L)
- OpenAlex
- W2015173632
- Semantic Scholar
- 6134862a99965c7a0faf46c2239c8d5f39b93403
- Cited by
- 343
- References
- 14
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 12 · 2017: 10 · 2016: 11 · 2015: 10 · 2014: 10 · 2013: 10 · 2012: 10
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Sensors and Actuators (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Semiconductor materials and devices
- Keywords
- ion-sensitive field-effect transistor, ion-selective electrodes, IGFET, ion migration, electrolyte solutions, integrated circuit fabrication, biomedical sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.