Methods of isfet fabrication
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We cannot signify the body effects in the SG operation, because the sensitivity of devices is in a similar distribution from 39.82 mV/pH to 47.19 mV/pH (Figure S3), within the reported sensitivity of 25 to 48 mV/pH25.”
From Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body (2014) · cites this paper as [25]
Citations
Cites
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
A Water-Amine-Complexing Agent System for Etching Silicon
Finne, R. M., & Klein, D. L. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426793 · Cited by 309
Potassium ion-sensitive field effect transistor
Moss, S. D., Janata, J., & Johnson, C. C. (1975) · Analytical Chemistry · doi:10.1021/ac60363a005 · Cited by 237
An Integrated Field-Effect Electrode for Biopotential Recording
Matsuo, T., & Wise, K. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324338 · Cited by 235
Self-citationIntegrated Micro Multi Ion Sensor Using Field Effect of Semiconductor
Esashi, M., & Matsuo, T. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326245 · Cited by 198
Self-citationAboaf, J. A. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426787 · Cited by 143
Selected Properties of Pyrolytic Ta[sub 2]O[sub 5] Films
Knausenberger, W. H., & Tauber, R. N. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403602 · Cited by 89
Applications of Immobilized Enzymes in Analytical Chemistry
Bowers, L. D., & Carr, P. W. (1976) · Analytical Chemistry · doi:10.1021/ac60371a033 · Cited by 74
Field effect potentiometric sensors
Buck, R. P., Hackleman, D. E., & Kenan, W. R. (1977) · Analytical Chemistry · doi:10.1021/ac50022a051 · Cited by 63
Properties of Vapor-Deposited Aluminum Arsenide
Sigai, A. G., Abrahams, M. S., & Blanc, J. (1972) · Journal of The Electrochemical Society · doi:10.1149/1.2404375 · Cited by 16
Research works printed but not linked: 4
- Abe, 1979, ISFETs using inorganic gate this films, IEEE trans. Electroc Devices, ED-26, 1939, 1944
- Tarui, 1969, Si MOS characteristics using vapor grown Al2O3 films, Rep. Electro. Tech. Lab. Jpn., 33, 578
- Comte, 1977, Reference ISFET for compensation, Proc. 30th ACEMB, 41-3
- Matsuo, 1978, Charasteristics of Parylene Gate ISFET, Extended Abstr. 153rd Meetings, ECS, Vol. 78-1, No. 83, Seattle
Cited by
Items 301–349 of 349
Influence of the aminated conditions on the pH sensitivity of silica and amorphous silicon film
Baccar, Z. M., Jaffrezic-Renault, N. J., Fourmond, E., Lemiti, M., & Grekov, F. F. (1997) · Journal of the European Ceramic Society · doi:10.1016/s0955-2219(97)00052-6 · Cited by 1
Ion image sensors based on CCD/CMOS technology
Sawada, K. (2012) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2012.6411558 · Cited by 1
Micro pH Sensors and Biosensors Based on Electrochemical Field Effect Transistors
Sasano, J., Niwa, D., & Ōsaka, T. (2009) · Nanostructure science and technology · doi:10.1007/978-1-4419-1424-8_10 · Cited by 1
“This pH sensitivity is quite similar to that of an ISFET such as the Si 3 N 4 gate FET [1, 4, 28], which shows a good Nernstian response.”
Interfacing Neurons and Silicon-Based Devices
Offenhäusser, A., Ingebrandt, S., Pabst, M., & Wrobel, G. (2009) · Nanostructure science and technology · doi:10.1007/978-0-387-09459-5_13 · Cited by 1
Silicon-Based Chemical Sensors
Madou, M. J., & Morrison, S. R. (1989) · Elsevier eBooks · doi:10.1016/b978-0-12-464965-1.50014-4 · Cited by 1
Lale, A., Grappin, A., Bourrier, D., Mazenq, L., Lecestre, A., Launay, J., & Temple‐Boyer, P. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994346 · Cited by 1
Sobre los materiales de encapsulado para electrodos selectivos de iones
Silveyra, J. M., Ureña, M. A., & Garrido, J. M. C. (2020) · Matéria (Rio de Janeiro) · doi:10.1590/s1517-707620200003.1094 · Cited by 1
Packaging of Biomolecular and Chemical Microsensors
Hesketh, P. J., & Lin, X. (2021) · Springer eBooks · doi:10.1007/978-3-030-49991-4_13 · Cited by 1
医学分野における表面処理 電気化学ナノテクノロジーのバイオ・医療分野への展開
Ōsaka, T., Sasano, J., Matsunaga, M., & Iida, H. (2008) · Journal of The Surface Finishing Society of Japan · doi:10.4139/sfj.59.355 · Cited by 1
High-Performance ISFET pH Sensor with HfO2Sensing Film Using Post-CMOS Processing
Grudtsov, V. P., Ryazantsev, D. V., Gubanova, O. V., Eganova, E. M., & Kuznetsov, A. E. (2023) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit58508.2023.10158889 · Cited by 1
“The pH dependence value was found to be 56 mV/pH, which is close to theoretical limit [9].”
BackgroundWireless Endoscopy: Technology and Design
Cumming, D. R. S., Hammond, P. A., & Wang, L. (2009) · Methods in molecular biology · doi:10.1007/978-1-60327-106-6_10 · Cited by 1
Desarrollo y caracterización de sensores químicos de estado sólido para aplicaciones biomédicas
Zine, N. (2005) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · Cited by 3
A multiple‐ISFET integrated with CMOS interface circuits
Tsukada, K., Maruizumi, T., & Miyagi, H. (1988) · Electronics and Communications in Japan (Part II Electronics) · doi:10.1002/ecjb.4420711211 · Cited by 1
ISFET incorporated in a differential amplifier
Tsukada, K., Maruizumi, T., & Miyagi, H. (1988) · Electronics and Communications in Japan (Part II Electronics) · doi:10.1002/ecjb.4420710309 · Cited by 1
Baraton, M. (2001) · MRS Proceedings · doi:10.1557/proc-705-y6.1 · Cited by 1
Wireless Sensor Microsystem Design: A Practical Perspective
Cumming, D. R. S., Hammond, P. A., Wang, L., Cooper, J. M., & Johannessen, E. A. (2007) · Springer eBooks · doi:10.1007/1-84628-484-8_11 · Cited by 1
Wearable sensors for monitoring of structural health and agricultural nutrient conditions
Jiao, Y. (2021) · doi:10.31274/td-20240329-866 · Cited by 1
Study on sensing properties of ISFETs fabricated with APTES/S1O2 stacked sensing membrane
Lee, T. N., Chen, H. J. H., & Hsieh, K. C. (2015) · IEEE International Conference on Electron Devices and Solid-State Circuits (EDSSC) · doi:10.1109/edssc.2015.7285241 · Cited by 1
Use of pH-ISFET sensors during extracorporeal circulation
Chauveau, N., Morucci, J. P., van den Vlekkert, H. H., de Rooij, N. F., & Barthélémy, R. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80254-w
Sakai, H. (1993) · Journal of Japan Society on Water Environment · doi:10.2965/jswe.16.183
Nakazawa, H., Watanabe, H., Ishida, M., & Sawada, K. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2191788 · Cited by 2
“Alternatively, Al2O3 and Ta2O5 are also used as pH-sensitive membranes [18]–[22].”
BackgroundHigh speed sensing using ion sensitive field effect transistors
Cumming, D. R. S., Shields, P., Piechocinski, M. S., & Nemeth, B. (2011) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2011.6004687
“[ 2 ]. These early devices relied on the use of a tailored”
BackgroundPerformance comparison of pH sensors fabricated in a CMOS process
Lee, L. A., Marx, S. R., Yotter, R. A., Booksh, K. S., Darling, R. B., & Wilson, D. M. (2006) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2004.1426283
M2O‐Al2O3‐SiO2 glass gate PNA and pK ISFETs
Shoji, S., Esashi, M., & Matsuo, T. (1986) · Electronics and Communications in Japan (Part II Electronics) · doi:10.1002/ecjb.4420690503
Self-citation4C3.05 A Physically-based Model for Drift in A120s-gate pH ISFET's
Jamasb, S., Collins, S. D., & Smith, R. L. (1997)
Quantificação de glicose intra e extra-celular por meio de biossensores micro e nanoestruturados
Nascimento, R. A. S. (2015) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.59.2015.tde-09112015-125339 · Cited by 1
Sawada, K., Dasai, F., Okumura, K., Futagawa, M., & 服部, 敏. (2016) · Springer eBooks · doi:10.1007/978-4-431-56429-4_3
Study the characteristics of uricase biosensor based on the extended gate field effect transistor
Liao, W.-L., & Chou, J.-C. (2005) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict.2004.1435177
Effect of surface functional groups on the pH sensitivity in ion-sensitive field effect transistors
Hong, N., Park, C., Kim, D., Jeong, K.-S., Yoon, J.-S., Jin, B., & Lee, J. (2016) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano.2016.7751374
“In order to mitigate these problems, various high-k dielectrics [11] or silanization treatments [4, 12] have been applied to the sensing membrane.”
BackgroundDrift Control and Vgs-output Response of High-sensitivity a-InGaZnO TFT pH Sensors
Iwamatsu, S., Yutaka, A. B. E., Konno, S., Katoh, M., Takechi, K., & Tanabe, H. (2017) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.137.89 · Cited by 1
3D Printed Ion-Selective Field Effect Transistors
Bao, C., Kaur, M., Kwack, Y., Choi, W., Lee, Y., Lee, T., & Kim, W. S. (2018) · IEEE International Flexible Electronics Technology Conference (IFETC) · doi:10.1109/ifetc.2018.8583990
“Through applying the voltage produced by the electrochemical reaction at interface between the ions selective membrane and the electrolyte, the drain current of FET can be controlled[1], [2].”
BackgroundWerner, C. F. (2014) · open_UMR Marburg DSpace 10.0 (Philipps-Universität Marburg) · doi:10.17192/z2014.0337
Tagawa, T., Tamura, T., & Oberg, P. A. (2011) · CRC Press eBooks · doi:10.1201/b10775-8
Development and Validation of a Novel Reliable Method for Wet Testing on Biochemical Chip
Lai, P.-T., Chiu, Y.-H., Lu, C.-W., Liu, K., Chiu, T.-L., & Chen, W. (2020) · IEEE International Test Conference in Asia (ITC-Asia) · doi:10.1109/itc-asia51099.2020.00016
Gubanova, O. V., Kuznetsov, E. V., Rybachek, E. N., & Saurov, A. N. (2020) · Russian Microelectronics · doi:10.1134/s1063739720070045
Oelßner, W., Decker, M., & Gerlach, G. (2019) · Wiley eBooks · doi:10.1002/9783527688302.ch10
Ōsaka, T., & Sayama, J. (2005) · Journal of The Surface Finishing Society of Japan · doi:10.4139/sfj.56.723
Full Range Crudes, Analytical Methodology of
Ali, M. A. (2015) · Wiley eBooks · doi:10.1002/9780470027318.a1815.pub2
Three‐Dimensional Microsensor Technology
Ache, H. J., Bürck, J., Faubel, W. N., Hoffmann, W. E., Reichert, J. C., Menz, W., Büstgens, B., Mohr, J., Müller, C., Schomberg, W., et al. (1995) · Sensors · doi:10.1002/9783527620180.ch4
Automation in Agriculture using Smart Instruments
Rabari, A., Joshi, S., Pandya, P., & Mistry, R. (2025) · International Journal of Advanced Research in Science Communication and Technology · doi:10.48175/ijarsct-23718
Ion Sensitive Field Effect Transistor for pH Sensing Application: A Simulation Based Analysis
Gajal, L., & Pandey, A. K. (2025) · Lecture notes in electrical engineering · doi:10.1007/978-3-031-84331-0_9
Defect chemistry in semiconductor-based amperometric electro- and photoelectrochemical devices
Rudatis, P. (2023) · reposiTUm (TU Wien) · doi:10.34726/hss.2023.42868
Félix, G. B. (2022) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Charge transport and positively charged defects in Ta2O5/SiO2 dielectric stacks
Kolkovsky, V. (2026) · Journal of Applied Physics · doi:10.1063/5.0307808
Development of micro-tools for biodetection, micromixing, and microfiltering
Lee, M. (2013) · theses.fr (ABES) · doi:10.70675/d76a05f7z10a3z4a7ez9f9ez9211f5d3f6c8
Ayele, G. T. (2019) · theses.fr (ABES) · doi:10.70675/444bfcc6zefe5z4ce2zba7dz73ddc8a5bf57 · Cited by 2
“Esashi published their work on pH sensing characteristics of different materials [45].”
Influential
Metadata
- Authors
- Matsuo, T., & Esashi, M.
- Affiliations
- Tohoku University (JP)
- Venue
- Sensors and Actuators
- Publisher
- Elsevier BV
- Published
- 1981-01
- Volume
- 1
- Pages
- 77-96
- ISSN
- 0250-6874 (ISSN-L)
- OpenAlex
- W2015173632
- Semantic Scholar
- 6134862a99965c7a0faf46c2239c8d5f39b93403
- Cited by
- 343
- References
- 14
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 12 · 2017: 10 · 2016: 11 · 2015: 10 · 2014: 10 · 2013: 10 · 2012: 10
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Sensors and Actuators (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Semiconductor materials and devices
- Keywords
- ion-sensitive field-effect transistor, ion-selective electrodes, IGFET, ion migration, electrolyte solutions, integrated circuit fabrication, biomedical sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.