Methods of isfet fabrication
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We cannot signify the body effects in the SG operation, because the sensitivity of devices is in a similar distribution from 39.82 mV/pH to 47.19 mV/pH (Figure S3), within the reported sensitivity of 25 to 48 mV/pH25.”
From Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body (2014) · cites this paper as [25]
Citations
Cites
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
A Water-Amine-Complexing Agent System for Etching Silicon
Finne, R. M., & Klein, D. L. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426793 · Cited by 309
Potassium ion-sensitive field effect transistor
Moss, S. D., Janata, J., & Johnson, C. C. (1975) · Analytical Chemistry · doi:10.1021/ac60363a005 · Cited by 237
An Integrated Field-Effect Electrode for Biopotential Recording
Matsuo, T., & Wise, K. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324338 · Cited by 235
Self-citationIntegrated Micro Multi Ion Sensor Using Field Effect of Semiconductor
Esashi, M., & Matsuo, T. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326245 · Cited by 198
Self-citationAboaf, J. A. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426787 · Cited by 143
Selected Properties of Pyrolytic Ta[sub 2]O[sub 5] Films
Knausenberger, W. H., & Tauber, R. N. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403602 · Cited by 89
Applications of Immobilized Enzymes in Analytical Chemistry
Bowers, L. D., & Carr, P. W. (1976) · Analytical Chemistry · doi:10.1021/ac60371a033 · Cited by 74
Field effect potentiometric sensors
Buck, R. P., Hackleman, D. E., & Kenan, W. R. (1977) · Analytical Chemistry · doi:10.1021/ac50022a051 · Cited by 63
Properties of Vapor-Deposited Aluminum Arsenide
Sigai, A. G., Abrahams, M. S., & Blanc, J. (1972) · Journal of The Electrochemical Society · doi:10.1149/1.2404375 · Cited by 16
Research works printed but not linked: 4
- Abe, 1979, ISFETs using inorganic gate this films, IEEE trans. Electroc Devices, ED-26, 1939, 1944
- Tarui, 1969, Si MOS characteristics using vapor grown Al2O3 films, Rep. Electro. Tech. Lab. Jpn., 33, 578
- Comte, 1977, Reference ISFET for compensation, Proc. 30th ACEMB, 41-3
- Matsuo, 1978, Charasteristics of Parylene Gate ISFET, Extended Abstr. 153rd Meetings, ECS, Vol. 78-1, No. 83, Seattle
Cited by
Items 201–300 of 349
Jan, S.-S., Chen, Y., Chou, J.-C., Jan, P.-J., & Cheng, C.-C. (2003) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2003.08.054 · Cited by 10
Lundström, I., van den Berg, A., van der Schoot, B. H., van den Vlekkert, H. H., Armgarth, M., & Nylander, C. I. (1991) · Sensors · doi:10.1002/9783527620135.ch10 · Cited by 10
Yoshimi, Y., Matsuda, T., Itoh, Y., Ogata, F., & Katsube, T. (1997) · Materials Science and Engineering C · doi:10.1016/s0928-4931(97)00031-3 · Cited by 9
Multimodal bio-image sensor for real-time proton and fluorescence imaging
Nakazawa, H., Ishida, M., & Sawada, K. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.010 · Cited by 9
Analytical application for chemicals using an enzyme sensor based on an ISFET
Sakai, H., Kaneki, N., & Hara, H. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)85099-v · Cited by 9
Herrmann, V., & Tesche, M. (1992) · Trees · doi:10.1007/bf00224493 · Cited by 9
Prototype sodium and potassium sensitive micro ISFETS
Ohta, Y., Shoji, S., Esahi, M., & Matsuo, T. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80059-5 · Cited by 9
Self-citationWakida, S., & Ujihira, Y. (1986) · Analytical Sciences · doi:10.2116/analsci.2.231 · Cited by 9
A novel urushi matrix sodium ion-selective field-effect transistor
Wakida, S., Yamane, M., & HIIRO, K. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87035-0 · Cited by 9
Study on polysilicon extended gate field effect transistor with samarium oxide sensing membrane
Kao, C. H., Chen, H., Chen, K. S., Huang, C.-Y., Huang, C., Ou, J.-C., Lin, C. J., Lin, K. M., & Kuo, L.-T. (2010) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict.2010.5667585 · Cited by 8
“Study on polysilicon extended gate field effect transistor with samarium oxide sensing membrane Chyuan-Haur Kao1, Hsian Chen2, Kung Shao Chen1, Chuan-Yu Huang1, Ching-Hua Huang1, Jiun-Cheng Ou1, Chih Ju Lin1, Keng Min Lin1, Lien Tai Kuo1 1Department of Electronic Engineering, Chang Gung University, 259 Wen Hsu 1stRd.,…”
BackgroundMoorthy, V. M., & Srivastava, V. M. (2023) · Recent Patents on Nanotechnology · doi:10.2174/1872210517666230414081056 · Cited by 8
Yang, C., Wang, C.-Y., & Lai, C. (2014) · Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena · doi:10.1116/1.4865479 · Cited by 8
Effects of Measurements Conditions on an Extended-Gate FET used as pH sensor
Fernandes, J. C., Nascimento, R. A. S., & Mulato, M. (2016) · Materials Research · doi:10.1590/1980-5373-mr-2015-0248 · Cited by 9
Survey on Ion Sensitive Field Effect Transistor from the View Point of pH Sensitivity and Drift
Hazarika, C., & Sharma, S. (2017) · Indian Journal of Science and Technology · doi:10.17485/ijst/2017/v10i37/118444 · Cited by 9
Biosensors Based on Field-Effect Devices
Junior, J. R. S., Fernandes, E. G. R., Oliveira, O. N., & Zucolotto, V. (2012) · Springer eBooks · doi:10.1007/978-3-642-29250-7_4 · Cited by 8
Micro- and nanotechnologies: dullish electrons and smart molecules
Simon, J. (2005) · Comptes Rendus Chimie · doi:10.1016/j.crci.2005.01.006 · Cited by 8
Pan, T.-M., Wang, C., Mondal, S., & Chang, Y. (2014) · The Journal of Physical Chemistry C · doi:10.1021/jp412311q · Cited by 8
Garu, P., Bag, S. P., & Pan, T.-M. (2021) · IEEE Electron Device Letters · doi:10.1109/led.2021.3055741 · Cited by 8
“performance because it is submerged in a test solution [2].”
Towards ISFET based DNA logic for rapid nucleic acid detection
Wong, W., Shepherd, L. M., Georgiou, P., & Toumazou, C. (2009) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2009.5398446 · Cited by 9
“The hydrolysis reaction produces or consumes hydrogen ions depending on the pH in which it occurs [12,13].”
BackgroundFabrication of Solid State Chemical Sensors
Huber, R. J. (1985) · Elsevier eBooks · doi:10.1016/b978-0-12-380210-1.50007-9 · Cited by 8
Ion‐Sensitive Field‐Effect Transistors
Hammond, P. A., & Cumming, D. R. S. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd148 · Cited by 8
Urban, G. A., & Jobst, G. (1998) · Topics in current chemistry · doi:10.1007/3-540-69544-3_8 · Cited by 8
Investigation on the sensitivity of TiO2:Ru pH sensor by Taguchi design of experiment
Yang, S., Chen, C., & Chou, J.-C. (2012) · Solid-State Electronics · doi:10.1016/j.sse.2012.05.024 · Cited by 7
Study on pH sensing properties of RF magnetron sputtered tantalum pentoxide (Ta2O5) thin film
Bahari, N., Zain, A. M., Abdullah, A. Z., Sheng, D. B. C., & Othman, M. A. (2010) · IEEE International Conference on Semiconductor Electronics · doi:10.1109/smelec.2010.5549429 · Cited by 7
“Thin film materials such as silicon nitride (Si3N4), titanium oxide (TiO2), zirconium oxide (ZrO2), aluminum oxide (Al2O3) and tantalum pentoxide (Ta2O5) have been reported as having hydrogen ion sensing properties for pH-ISFET application [1].”
BackgroundOyama, N., Ohsaka, T., Ikeda, S., & Okuaki, K. (1989) · Analytical Sciences · doi:10.2116/analsci.5.729 · Cited by 7
Rochefeuille, S., Berjoan, R., Patrick, S. E. T. A., Jiménez‐Jorquera, C., & Desfours, J. P. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(03)00978-3 · Cited by 7
Jamasb, S., Collins, S. D., & Smith, R. L. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758833 · Cited by 7
“The inaccuracies in estimation of large step changes in pH are due to errors resulting from the hysteresis phenomenon which occurs when the pH is ramped up and down [ 6 ,12].”
BackgroundMicro-fabrication of Biosensors
Karube, I., Tamiya, E., & Suzuki, H. R. (1988) · Elsevier eBooks · doi:10.1016/b978-0-444-98901-7.50017-8 · Cited by 7
Esashi, M., & Matsuo, T. (1987) · Springer eBooks · doi:10.1007/978-94-009-3361-3_13 · Cited by 7
Self-citationMeasurements of the Electrostatic Potential at the Mineral/Electrolyte Interface
Klačić, T., Katić, J., Kovačević, D., Namjesnik, D., Abdelmonem, A., & Begović, T. (2025) · Reviews in Mineralogy and Geochemistry · doi:10.2138/rmg.2025.91a.09 · Cited by 6
Two-Regime Drift in Electrolytically Gated FETs and BioFETs
Wuytens, R., Santermans, S., Gupta, M., Bois, B. D., Severi, S., Lagae, L., Roy, W. V., & Martens, K. M. (2020) · IEEE International Reliability Physics Symposium proceedings · doi:10.1109/irps45951.2020.9129124 · Cited by 6
“Little work to date has addressed reliability challenges [6-10].”
BackgroundBismuth Oxide Extended-Gate Field-Effect Transistor as pH Sensor
Sharma, P., Singh, R., Sharma, R., Mukhiya, R., Awasthi, K., & Kumar, M. (2022) · Journal of Electronic Materials · doi:10.1007/s11664-022-09526-6 · Cited by 6
Suzurikawa, J., Nakao, M., & Takahashi, H. (2011) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.20674 · Cited by 6
Development of Sugar Sensitive Drosophila Cell based ISFET Sensor for Alzheimer's Disease Diagnosis
Lim, J.-O., Yu, J.-B., Kwon, J.-Y., Byun, H., Huh, J.-S., & Cho, W.-J. (2013) · Journal of Sensor Science and Technology · doi:10.5369/jsst.2013.22.4.281 · Cited by 6
“또한, 세포와 반응물질간의 신호를 민감하게 detection 할수있도록SiO2 물질을감지막으로사용하였으며, 소 자의 감도와 안정성에 대한 특성 분석을 실시 하였다[11-14].”
Lai, C., Lue, C.-E., Yang, C., & Pijanowska, D. G. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3250978 · Cited by 6
Chiang, J. L., Chou, J. C., & Chen, Y.-C. (2002) · Optical Engineering · doi:10.1117/1.1482099 · Cited by 7
Advances in Enzymatically Coupled Field Effect Transistors
Shiono, S., Hanazato, Y., & Nakako, M. (1992) · Methods of biochemical analysis · doi:10.1002/9780470110577.ch6 · Cited by 6
Urea Sensitive Field Effect Transistors Based on Dithio Group-Containing Langmuir–Blodgett Membranes
Lee, S., Anzai, J., & Osa, T. (1991) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.64.2019 · Cited by 6
Développement des microcapteurs ChemFETs pour l’analyse de l’eau
Humenyuk, I. (2005) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 6
Karube, I., & Gotoh, M. (1988) · Springer eBooks · doi:10.1007/978-94-009-2895-4_22 · Cited by 6
Modeling of carbon nanotube ISFETs with high‐κ gate dielectrics for biosensing applications
Thakur, H. R., & Dutta, J. C. (2019) · International Journal of Numerical Modelling Electronic Networks Devices and Fields · doi:10.1002/jnm.2654 · Cited by 6
“This experimental curve for ψ0has been obtained by using the experimentally obtained threshold voltages from the transfer characteristic curves shown in Figure 7B,D for HfO2 and ZrO2 CNTFETs and Figure 7C,E for HfO2 and ZrO2 CNT‐ISFETs using ELR method (in this method, the tangent is drawn at the linear region giving…”
InfluentialSeki, A., Kubo, I., Sasabe, H., & Tomioka, H. (1994) · Applied Biochemistry and Biotechnology · doi:10.1007/bf02788742 · Cited by 5
Katayama, S., Akao, N., Hara, N., & Sugimoto, K. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1945607 · Cited by 5
Modelling of the migration effect occurring at an ISFET-based coulometric sensor-actuator system
Luo, J., Olthuis, W., van der Schoot, B. H., Bergveld, P., Bos, M. J., & van der Linden, W. E. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83903-3 · Cited by 5
pH-sensitive ISFETs based on titanium nitride and their application to battery monitor
Wakida, S., Mochiziuki, S., MAKABE, R., Kawahara, A., Yamane, M., TAKASUKA, S., & HIGASHI, K. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148842 · Cited by 5
EGFET Differential Pair with ITO as the Extended-Gate Membrane for pH-Sensing
Mokhtarifar, N., Goldschmidtboeing, F., & Woias, P. (2018) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2018.8556927 · Cited by 5
“ISFETs are solid-state sensors with a small size, low output impedance and suitable for multiple ion species detection at a same time [1].”
BackgroundLundström, I., van den Berg, A., van der Schoot, B. H., van den Vlekkert, H. H., Armgarth, M., & Nylander, C. I. (1995) · Wiley eBooks · doi:10.1002/9783527619269.ch10a · Cited by 5
Corrosion Monitoring Techniques for Thermally Driven Wet and Dry Conditions
Sridhar, N., Dunn, D. S., Brossia, C. S., & Moghissi, O. C. (2000) · NACE CORROSION Conference · doi:10.5006/c2000-00283 · Cited by 5
Gupta, A., Sharma, S., & Goswami, R. (2024) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/ad3d07 · Cited by 5
Yang, C., Chang, J.-Y., Remiszewska, E., Urbanowicz, M., Ughi, F., Wei, C., Pijanowska, D. G., & Lai, C. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3570755 · Cited by 5
“Since Matsuo and Esashi [8] first realized tantalum oxide (Ta 2 O 5 ) as a sensing film for ISFETs in 1981, many researchers have presented various sensing films, such as aluminum oxide (Al 2 O 3 ) [9], titanium oxide (TiO 2 ) [10], and titanium nitride (TiN) films [11].”
An ISFET Interface Circuitry for Biomedical Applications
Yang, C.-H., & Liao, Y.-W. (2007) · IEEE International Conference on Electron Devices and Solid-State Circuits (EDSSC) · doi:10.1109/edssc.2007.4450316 · Cited by 4
Long Term Drift Observed in ISFET Due to the Penetration of H+ Ions into the Oxide Layer
Hazarika, C., Neroula, S., & Sharma, S. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-34872-4_60 · Cited by 4
On the Atomic Layer Deposition of Tantalum Oxide for Field Effect Sensors
Grudtsov, V. P., Eganova, E. M., Gubanova, O. V., Goryachev, A. V., Владимирович, П. К., Ryazantsev, D. V., Kuznetsov, A. E., & Komarova, N. V. (2024) · Semiconductors · doi:10.1134/s1063782625700034 · Cited by 4
Sawada, K., Nakazawa, H., Takenaga, S., Hizawa, T., Futagawa, M., Dasai, F., Sakurai, T., Okumura, K., 服部, 敏., & Ishida, M. (2014) · IEICE Transactions on Fundamentals of Electronics Communications and Computer Sciences · doi:10.1587/transfun.e97.a.726 · Cited by 4
A high-speed small-area pixel 16 × 16 ISFET array design using 0.35-μm CMOS process
Yang, L., Zhang, X., Zhang, Q. M., Tan, M., & Yu, Y. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.03.003 · Cited by 4
Test structures for ISFET chemical sensors
Gràcia, I., Cane, C., Lozano, M., & Estéve, J. (2003) · IEEE International Conference on Microelectronic Test Structures (ICMTS) · doi:10.1109/icmts.1992.185959 · Cited by 4
“However, integrated ISFET's in contact with a liquid present some problems that are not fully solved nowadays: drifts and difficult packaging [ 2 ].”
BackgroundPotassium Ion-Selective Field Effect Transistor with Urushi as the Membrane Matrix
Wakida, S., Yamane, M., HIIRO, K., Ara, T. K., Ujihira, Y., & Sugano, T. (1988) · Analytical Sciences · doi:10.2116/analsci.4.501 · Cited by 4
Biosensors based on ion-selective field effect transistors: theory, technology, practice
Dzyadevych, S. V. (2004) · Biopolymers and Cell · doi:10.7124/bc.000686 · Cited by 12
Hazarika, C., Sarma, D. J., Puzari, P., Medhi, T., & Sharma, S. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2847693 · Cited by 4
Karube, I., & Moriizumi, T. (1988) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(88)37024-2 · Cited by 4
Ion beam sensitized SiO2 surface for halide ions
Pham, M. T., Matz, W., Möller, D., & Hüller, J. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00537-4 · Cited by 4
Silicon Nanoribbon FET Sensors : Fabrication, Surface Modification and Microfluidic Integration
Afrasiabi, R. (2016) · DiVA (Digitala Vetenskapliga Arkivet) · Cited by 6
Modeling and performance analysis of high-k gate material-based isfet biosensors using TCAD
Zenita, P., Devi, A. B., Singh, K. J., & Singh, N. B. (2025) · Journal of Computational Electronics · doi:10.1007/s10825-025-02434-y · Cited by 3
Kinetics of the hydration reaction at the electrolyte–insulator interface
Jamasb, S. (2017) · Surface Engineering and Applied Electrochemistry · doi:10.3103/s1068375517010069 · Cited by 3
Lale, A., Grappin, A., Mazenq, L., Bourrier, D., Lecestre, A., Launay, J., & Temple‐Boyer, P. (2017) · EUROSENSORS Conference (EUROSENSORS) · doi:10.3390/proceedings1040419 · Cited by 3
“This Al2O3 layer was used as a gate chemically sensitive layer as well as the microdevice passivation layer in liquid phase [3,6].”
MethodFlexible integrated chemical and physical sensors toward a wearable healthcare patch
Nakata, S., Arie, T., Akita, S., & Takei, K. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994390 · Cited by 5
“Another method to measure pH and other chemical is ISFET, which has been proposed especially for Si-based inflexible electronics [6].”
MethodFabrication and characterization of a pH sensor
Rodrigues, F., & Boudinov, H. I. (2017) · Symposium on Microelectronics Technology and Devices · doi:10.1109/sbmicro.2017.8112979 · Cited by 3
“This has been reported in literature and is a common problem of SiO2 sensitive layers [8].”
BackgroundFutagawa, M., Uemura, K., Oishi, R., Ota, S., & Hirano, H. (2019) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2019.8808728 · Cited by 3
“Because the device can be fabricated using a Si-LSI process [2], multi-pixel type devices [3] and high functional devices [4] have been studied by various groups.”
MethodA Novel Conditioning Circuit for Floating-Gate ISFET Bio-Sensor
Gaddour, A., Hassen, H. B., Dghais, W., Hamdi, B., & Ali, M. B. (2021) · International Journal of Circuits Systems and Signal Processing · doi:10.46300/9106.2021.15.128 · Cited by 3
“he Floating-Gate Ion-Sensitive Field-Effect Transistors (FG-ISFETs) since their introduction over decades ago, have become essential today due to their many applications in very varied fields[1-4].”
Development of microbiosensors
Karube, I. (1988) · Makromolekulare Chemie Macromolecular Symposia · doi:10.1002/masy.19880170131 · Cited by 3
High Sensitivity pH Sensors based on Amorphous Indium-gallium-zinc Oxide Thin-film Transistors
Iwamatsu, S., Yutaka, A. B. E., Yahagi, T., Kobayashi, S., Takechi, K., & Tanabe, H. (2015) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.135.192 · Cited by 3
Three‐Dimensional Microsensor Technology
Ache, H. J., Bürck, J., Faubel, W. N., Hoffmann, W. E., Reichert, J. C., Menz, W., Büstgens, B., Mohr, J., Müller, C., Schomberg, W., et al. (1995) · Wiley eBooks · doi:10.1002/9783527619269.ch4g · Cited by 3
Kubo, I., Karube, I., & Moriizumi, T. (1986) · Analytical Letters · doi:10.1080/00032718608064530 · Cited by 3
A study of borazon-gate pH-sensitive field effect transistors
Olszyna, A. R., Włosiński, W., Sobczyńska, D., & Torbicz, W. (1987) · Journal of Crystal Growth · doi:10.1016/s0022-0248(87)80022-2 · Cited by 3
Development of Low-Drift pH Electrodes Based on Neutral Carrier in PVC Overlayered Metallizations
Rhodes, R. K. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325882 · Cited by 3
MEINDL, J. D., Ford, A. J., TAPERELL, R. E., Bazuin, B. J., ABADI, K., Bowman, L., Smith, M. J. S., DORMAN, M. G., Schmitt, J. M., Harame, D. L., et al. (1986) · Elsevier eBooks · doi:10.1016/b978-0-12-278007-3.50006-x · Cited by 3
Esashi, M. (1990) · Springer eBooks · doi:10.1007/978-3-642-45678-7_69 · Cited by 3
Self-citationThakur, H. R., Keshwani, G., & Dutta, J. C. (2019) · International Conference on Innovations in Electronics, Signal Processing and Communication (IESC) · doi:10.1109/iespc.2019.8902394 · Cited by 2
“The drift behavior of Si3N4, Al2O3, Ta2O5, AlN and SnO2 gate dielectric materials have been studied by various groups [6-10].”
BackgroundSensitization of silicon nitride surfaces for Ag+ ions by ion implantation
Möller, D., Pham, M. T., & Hüller, J. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00197-4 · Cited by 2
Yang, C., Wei, C., Chang, J.-Y., & Lai, C. (2024) · Nanomaterials · doi:10.3390/nano14141191 · Cited by 2
“…good stability with a small drift effect, which is comparable to that of HfO 2 [47], RuN [48], and Ta 2 O 5 [52] and better than that of Si 3 N 4 [53] and SnO 2 [54]. effect, which is comparable to that of HfO 2 [47], RuN [48], and Ta 2 O 5 [52] and better than that of Si 3 N 4 [53] and SnO 2 [54].”
ResultPositively Charged Defects in Ta2O5 and Nb2O5: Are They Correlated with Sodium Ions?
Kolkovsky, V., & Kurth, E. (2024) · physica status solidi (a) · doi:10.1002/pssa.202400280 · Cited by 2
Wakida, S., Kohigashi, Y., HIGASHI, K., & Ujihira, Y. (2005) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1995.721991 · Cited by 2
Wireless Sensor Microsystem Design: A Practical Perspective
Wang, L., Cumming, D. R. S., Hammond, P. A., Cooper, J. M., Johannessen, E. A., & Ivanov, K. (2014) · Springer eBooks · doi:10.1007/978-1-4471-6374-9_11 · Cited by 2
“To avoid polarising the reference electrode, common to such devices, a leakage current of less than 1nA is desirable [ 79 ].”
BackgroundWeng, C. S., Hashim, U., & Liu, W. (2013) · IEEE Regional Symposium on Micro and Nanoelectronics · doi:10.1109/rsm.2013.6706508 · Cited by 2
“This result agrees with published values in the literature [9,10,11].”
ResultJhan, S.-S., Chiang, J.-L., Chen, Y., Chou, J.-C., & Su, J.-F. (2009) · Ferroelectrics · doi:10.1080/00150190902888533 · Cited by 2
Temperature Dependence of Surface Potential in a-Si:H pH-Ion Sensitive Field Effect Transistor
Chou, J. C., Wang, Y. F., & Tsai, H.-M. (2001) · Japanese Journal of Applied Physics · doi:10.1143/jjap.40.3975 · Cited by 2
The characterization of stacked α-Si/SiGe/α-Si sensing membrane
Yang, C., Lai, C., Wang, C.-Y., Lue, C.-E., Chou, J.-C., Chung, W., & Pijanowska, D. G. (2005) · Microelectronic Engineering · doi:10.1016/j.mee.2005.04.041 · Cited by 2
Dodgson, J. R. (1991) · Springer eBooks · doi:10.1007/978-1-4615-3818-9_34 · Cited by 2
Low-cost pH, temperature and ion concentration sensors utilizing laser machined touch panel film
Kao, W.-H., & Lin, C. (2017) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2017.8016985 · Cited by 2
“is thought to be a cheap solution to produce a small and disposable pH sensor.[6-10] The metal layer of a commercial metal-oxide-semiconductor field effect transistors (MOSFETs) was removed to measure hydrogen ion concentration by Bergveld in 1970.”
MethodSensitization of Dielectric Surfaces by Chemical Grafting Application to ISFETs and ENFETs
Cléchet, P., Jaffrezic-Renault, N. J., & Martelet, C. (1992) · Elsevier eBooks · doi:10.1016/b978-0-444-98680-1.50017-6 · Cited by 2
Full Range Crudes, Analytical Methodology of
Ali, M. A. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a1815 · Cited by 2
Biosensor Design and Fabrication
Urban, G. A. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a0505 · Cited by 2
Prototype of micro ISFET for biomedical research
Shoji, S., Esashi, M., & Matsuo, T. (1986) · Electronics and Communications in Japan (Part II Electronics) · doi:10.1002/ecjb.4420690603 · Cited by 2
Self-citationMicrobiosensors for Clinical and Process Analysis
Karube, I., & Tamiya, E. (1989) · Springer eBooks · doi:10.1007/978-3-642-74227-9_27 · Cited by 2
Single Drop Acid-Rain Analysis Using Microsensors
Wakida, S., Yamane, M., Tsujimura, Y., Wu, X., & Liu, J. (2001) · Springer eBooks · doi:10.1007/978-3-642-59497-7_290 · Cited by 2
Karube, I., & Kubo, I. (1988) · Springer eBooks · doi:10.1007/978-94-009-2895-4_17 · Cited by 2
CCD based ion image sensors for novel bio imaging — Fusion of Sensor technology and LSI technology
Sawada, K. (2012) · International Conference on Optical MEMS and Nanophotonics · doi:10.1109/omems.2012.6318879 · Cited by 1
Agarwal, N., & Agarwal, N. (2024) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126624502578 · Cited by 1
Packaging of Biomolecular and Chemical Microsensors
Hesketh, P. J., & Lin, X. (2009) · Springer eBooks · doi:10.1007/978-1-4419-0040-1_16 · Cited by 1
Effect of two types of surface sites on the characteristics of Si/sub 3/N/sub 4/-gate pH-ISFET's
Niu, M.-N., Ding, X.-F., & Tong, Q. (2002) · IEEE International Conference on Semiconductor Electronics · doi:10.1109/smelec.1996.616480 · Cited by 1
Metadata
- Authors
- Matsuo, T., & Esashi, M.
- Affiliations
- Tohoku University (JP)
- Venue
- Sensors and Actuators
- Publisher
- Elsevier BV
- Published
- 1981-01
- Volume
- 1
- Pages
- 77-96
- ISSN
- 0250-6874 (ISSN-L)
- OpenAlex
- W2015173632
- Semantic Scholar
- 6134862a99965c7a0faf46c2239c8d5f39b93403
- Cited by
- 343
- References
- 14
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 12 · 2017: 10 · 2016: 11 · 2015: 10 · 2014: 10 · 2013: 10 · 2012: 10
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Sensors and Actuators (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Semiconductor materials and devices
- Keywords
- ion-sensitive field-effect transistor, ion-selective electrodes, IGFET, ion migration, electrolyte solutions, integrated circuit fabrication, biomedical sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.