Methods of isfet fabrication
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We cannot signify the body effects in the SG operation, because the sensitivity of devices is in a similar distribution from 39.82 mV/pH to 47.19 mV/pH (Figure S3), within the reported sensitivity of 25 to 48 mV/pH25.”
From Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body (2014) · cites this paper as [25]
Citations
Cites
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
A Water-Amine-Complexing Agent System for Etching Silicon
Finne, R. M., & Klein, D. L. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426793 · Cited by 309
Potassium ion-sensitive field effect transistor
Moss, S. D., Janata, J., & Johnson, C. C. (1975) · Analytical Chemistry · doi:10.1021/ac60363a005 · Cited by 237
An Integrated Field-Effect Electrode for Biopotential Recording
Matsuo, T., & Wise, K. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324338 · Cited by 235
Self-citationIntegrated Micro Multi Ion Sensor Using Field Effect of Semiconductor
Esashi, M., & Matsuo, T. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326245 · Cited by 198
Self-citationAboaf, J. A. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426787 · Cited by 143
Selected Properties of Pyrolytic Ta[sub 2]O[sub 5] Films
Knausenberger, W. H., & Tauber, R. N. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403602 · Cited by 89
Applications of Immobilized Enzymes in Analytical Chemistry
Bowers, L. D., & Carr, P. W. (1976) · Analytical Chemistry · doi:10.1021/ac60371a033 · Cited by 74
Field effect potentiometric sensors
Buck, R. P., Hackleman, D. E., & Kenan, W. R. (1977) · Analytical Chemistry · doi:10.1021/ac50022a051 · Cited by 63
Properties of Vapor-Deposited Aluminum Arsenide
Sigai, A. G., Abrahams, M. S., & Blanc, J. (1972) · Journal of The Electrochemical Society · doi:10.1149/1.2404375 · Cited by 16
Research works printed but not linked: 4
- Abe, 1979, ISFETs using inorganic gate this films, IEEE trans. Electroc Devices, ED-26, 1939, 1944
- Tarui, 1969, Si MOS characteristics using vapor grown Al2O3 films, Rep. Electro. Tech. Lab. Jpn., 33, 578
- Comte, 1977, Reference ISFET for compensation, Proc. 30th ACEMB, 41-3
- Matsuo, 1978, Charasteristics of Parylene Gate ISFET, Extended Abstr. 153rd Meetings, ECS, Vol. 78-1, No. 83, Seattle
Cited by
Nakata, S., Arie, T., Akita, S., & Takei, K. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00047 · Cited by 379
Simultaneous DNA amplification and detection using a pH-sensing semiconductor system
Toumazou, C., Shepherd, L. M., Reed, S. C., Chen, G. I., Patel, A., Garner, D. M., Wang, C.-J. A., Ou, C.-P., Amin-Desai, K., Athanasiou, P., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2520 · Cited by 356
Surface chemistry and tip-sample interactions in atomic force microscopy
Senden, T. J., & Drummond, C. J. (1995) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(94)02954-q · Cited by 252
A physical model for drift in pH ISFETs
Jamasb, S., Collins, S., & Smith, R. L. (1998) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00040-9 · Cited by 239
Ion-sensing devices with silicon nitride and borosilicate glass insulators
Harame, D. L., Bousse, L. J., Shott, J. D., & Meindl, J. D. (1987) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1987.23140 · Cited by 225
Alvarez-Icaza, M., & Bilitewski, U. (1993) · Analytical Chemistry · doi:10.1021/ac00059a717 · Cited by 221
Hysteresis in Al2O3-gate ISFETs
Bousse, L., van den Vlekkert, H. H., & de Rooij, N. F. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80018-u · Cited by 180
Chiang, J.-L., Jan, S.-S., Chou, J.-C., & Chen, Y. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00657-8 · Cited by 163
Zeta potential measurements of Ta2O5 and SiO2 thin films
Bousse, L. J., Mostarshed, S., Shoot, B. V. D., de Rooij, N. F., Gimmel, P., & Göpel, W. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90130-z · Cited by 148
Highly sensitive palladium oxide thin film extended gate FETs as pH sensor
Das, A., Ko, D. H., Chen, C.-H., Chang, L., Lai, C., Chu, F.-C., Chow, L., & Lin, R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.08.057 · Cited by 148
“[7], various research groups have demonstrated the use of different sensing membranes such as Al2O3 [8], Si3N4 [4], SnO2 [9], Er2O3 [10], Si nanowire/SiO2/Al2O3 [11], IrOX [12], Gd2O3/SiO2 stacked oxide [13], silicon nanowire [14], Ru-doped TiO2 [15] film in order to enhance detection capabilities.”
BackgroundEnzyme biosensors based on ion-selective field-effect transistors
Dzyadevych, S. V., Soldatkin, A. P., El'skaya, A. V., Martelet, C., & Jaffrezic-Renault, N. J. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.11.057 · Cited by 149
Porous silicon as a substrate material for potentiometric biosensors
Thust, M., Schöning, M. J., Frohnhoff, S., Arens-Fischer, R., Kordos, P., & Luth, H. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/1/003 · Cited by 136
Jamasb, S., Collins, S. D., & Smith, R. L. (1998) · IEEE Transactions on Electron Devices · doi:10.1109/16.678525 · Cited by 133
“The surface of a silicon nitride film is known to undergo a relatively slow conversion to a hydrated SiO layer or an oxynitride during contact with an aqueous solution [2], [4], [ 5 ], [9]‐[11], [16].”
BackgroundInfluentialLiao, Y.-H., & Chou, J.-C. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.07.023 · Cited by 134
Investigation by atomic force microscopy of forces at the origin of cement cohesion
Lesko, S., Lesniewska, É., Nonat, A., Mutin, J.-C., & Goudonnet, J. (2001) · Ultramicroscopy · doi:10.1016/s0304-3991(00)00091-7 · Cited by 125
Prototype miniature blood gas analyser fabricated on a silicon wafer
Shoji, S., Esashi, M., & Matsuo, T. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)80057-x · Cited by 124
Self-citationA comprehensive review of FET‐based pH sensors: materials, fabrication technologies, and modeling
Sinha, S., & Pal, T. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100147 · Cited by 118
An Integrated Sensor for Electrochemical Measurements
Smith, R. L., & Scott, D. C. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325881 · Cited by 125
“encapsulation by micromachining the silicon sensors into the shape of small needles and depositing 50-150 nm Si3N4 entirely around the tip of the needle [9], [10].”
BackgroundMethodChou, J. C., & Wang, Y. F. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00147-8 · Cited by 114
Jang, H.-J., & Cho, W.-J. (2014) · Scientific Reports · doi:10.1038/srep05284 · Cited by 103
The temperature dependence of the surface potential at the Al2O3/electrolyte interface
van den Vlekkert, H. H., Bousse, L. J., & de Rooij, N. (1988) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(88)90369-4 · Cited by 101
Effects of heat treatment on Ta2O5 sensing membrane for low drift and high sensitivity pH-ISFET
Kwon, D., Cho, B.-W., Kim, C.-S., & Sohn, B. (1996) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(96)01938-7 · Cited by 100
Chemical and biological sensors
Nylander, C. (1985) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/18/9/003 · Cited by 117
A CMOS-integrated 'ISFET-operational amplifier' chemical sensor employing differential sensing
Wong, H. ‐. P., & White, M. (1989) · IEEE Transactions on Electron Devices · doi:10.1109/16.19957 · Cited by 95
Detection of pH variation using modified microcantilever sensors
Ji, H., Hansen, K. M., Hu, Z., & Thundat, T. G. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00678-x · Cited by 92
“Aluminum oxide-coated surfaces have been shown to be sensitive to pH, for example, Al2O3 has been used to modify ISFET gate surfaces [17,18].”
MethodStudy of indium tin oxide thin film for separative extended gate ISFET
Yin, L., Chou, J.-C., Chung, W., Sun, T., & Hsiung, S.-K. (2001) · Materials Chemistry and Physics · doi:10.1016/s0254-0584(00)00373-4 · Cited by 91
Miniaturization of potentiometric sensors using porous silicon microtechnology
Schöning, M. J., Ronkel, F., Crott, M., Thust, M., Schultze, J. W., Kordos, P., & Luth, H. (1997) · Electrochimica Acta · doi:10.1016/s0013-4686(97)00172-2 · Cited by 84
Time-dependence of the chemical response of silicon nitride surfaces
Bousse, L. J., Hafeman, D. G., & Tran, N. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80231-n · Cited by 84
Jang, H., & Cho, W.-J. (2012) · Applied Physics Letters · doi:10.1063/1.3685497 · Cited by 84
Effect of two types of surface sites on the characteristics of Si3N4-gate pH-ISFETs
Niu, M.-N., Ding, X.-F., & Tong, Q. (1996) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)80067-6 · Cited by 82
Improvement of integrated Ag/AgCl thin-film electrodes by KCl-gel coating for ISFET applications
Huang, I., Huang, R., & Lo, L. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00326-5 · Cited by 82
Futagawa, M., Iwasaki, T., Murata, H., Ishida, M., & Sawada, K. (2012) · Sensors · doi:10.3390/s120608338 · Cited by 81
“Several kinds of membrane material have been used [32] such as Si3N4, Ta2O5, Al2O3, SiO2, and so on.”
BackgroundBiosensors based on light-addressable potentiometric sensors for urea, penicillin and glucose
Seki, A., Ikeda, S.-I., Kubo, I., & Karube, I. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00364-x · Cited by 80
On the impedance of the silicon dioxide/electrolyte interface
Bousse, L. J., & Bergveld, P. (1983) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(83)80030-8 · Cited by 80
New ISFET sensor interface circuit for biomedical applications
Palan, B., dos Santos, F. V., Karam, J. M., Courtois, B., & Hušák, M. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00136-7 · Cited by 79
One Step Fabrication of Microbiosensor Prepared by the Codeposition of Enzyme and Platinum Particles
Ikariyama, Y., Yamauchi, S., Yukiashi, T., & Ushioda, H. (1987) · Analytical Letters · doi:10.1080/00032718708082596 · Cited by 77
Microtechnologies for PH ISFET chemical sensors
Cane, C., Gràcia, I., & Merlos, Á. (1997) · Microelectronics Journal · doi:10.1016/s0026-2692(96)00068-7 · Cited by 77
Study of amorphous tin oxide thin films for ISFET applications
Liao, H.-K., Chou, J.-C., Chung, W., Sun, T., & Hsiung, S.-K. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00162-2 · Cited by 75
A microsensor for urea based on an ion-selective field effect transistor
Karbue, I., Tamiya, E., Dicks, J. M., & Gotoh, M. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80046-0 · Cited by 74
Sensitivity and hysteresis effect in Al2O3 gate pH-ISFET
Chou, J.-C., & Weng, C.-Y. (2001) · Materials Chemistry and Physics · doi:10.1016/s0254-0584(00)00513-7 · Cited by 77
Acetylcholine Sensor Based on Ion Sensitive Field Effect Transistor and Acetylcholine Receptor
Gotoh, M., Tamiya, E., Momoi, M. Y., Kagawa, Y., & Karube, I. (1987) · Analytical Letters · doi:10.1080/00032718708062935 · Cited by 73
Takenaga, S., Schneider, B., Erbay, E., Biselli, M., Schnitzler, T., Schöning, M. J., & Wagner, T. (2015) · physica status solidi (a) · doi:10.1002/pssa.201532053 · Cited by 72
A highly long-term stable silicon-based pH sensor fabricated by pulsed laser deposition technique
Schöning, M. J., Tsarouchas, D., Beckers, L., Schubert, J., Zander, W., Kordos, P., & Luth, H. (1996) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)80060-3 · Cited by 72
Action potentials of HL-1 cells recorded with silicon nanowire transistors
Eschermann, J. F., Stockmann, R., Hueske, M., Vu, X. T., Ingebrandt, S., & Offenhäusser, A. (2009) · Applied Physics Letters · doi:10.1063/1.3194138 · Cited by 76
Mikolajick, T., Kühnhold, R., & Ryssel, H. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00166-4 · Cited by 74
A process for the combined fabrication of ion sensors and CMOS circuits
Bousse, L. J., Shott, J. D., & MEINDL, J. D. (1988) · IEEE Electron Device Letters · doi:10.1109/55.20408 · Cited by 66
Sensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65
Rigante, S., Scarbolo, P., Wipf, M., Stoop, R. L., Bedner, K., Buitrago, E., Bazigos, A., Bouvet, D., Calame, M., Schönenberger, C., et al. (2015) · ACS Nano · doi:10.1021/nn5064216 · Cited by 73
The super-Nernstian pH sensitivity of Ta2O5-gate ISFETs
Poghossian, A. (1992) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(92)80326-s · Cited by 64
A System-on-Chip Digital pH Meter for Use in a Wireless Diagnostic Capsule
Hammond, P. A., Ali, D., & Cumming, D. R. S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844041 · Cited by 67
“Silicon nitride is a well-known material for ISFET fabrication and gives a linear pH-response with a sensitivity in the range of 45–56 mV/pH [16].”
BackgroundRecent advances in ion‐sensitive field‐effect transistors for biosensing applications
Ma, X., Peng, R., Mao, W., Lin, Y., & Yu, H. (2022) · Electrochemical Science Advances · doi:10.1002/elsa.202100163 · Cited by 64
Study of high-k Er2O3 thin layers as ISFET sensitive insulator surface for pH detection
Pan, T.-M., Lin, J.-C., Wu, M., & Lai, C. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.01.051 · Cited by 65
A microsensor for adenosine-5′-triphosphate pH-sensitive field effect transistors
Gotoh, M., Tamiya, E., Karube, I., & Kagawa, Y. (1986) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82920-7 · Cited by 61
V2O5/WO3Mixed Oxide Films as pH-EGFET Sensor: Sequential Re-Usage and Fabrication Volume Analysis
Guidelli, É. J., Guerra, E. M., & Mulato, M. (2012) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.007203jss · Cited by 60
An Analytical Technique for Counteracting Drift in Ion-Selective Field Effect Transistors (ISFETs)
Jamasb, S. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.833148 · Cited by 66
“As a result of exposure to an aqueous solution, the surface of the common gate insulators used as the pH-sensitive film (e.g., Si N ) in ISFETs undergoes chemical modification [ 8 ], [21], [23].”
BackgroundMethodA very large integrated pH-ISFET sensor array chip compatible with standard CMOS processes
Yeow, T. C. W., Haskard, M. R., Mulcahy, D. E., Seo, H. I., & Kwon, D. H. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00207-4 · Cited by 58
Amperometric enzyme biosensors for the analysis of drugs and metabolites
Harwood, G. W. J., & Pouton, C. W. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00093-m · Cited by 70
Micromachined packaging for chemical microsensors
Smith, R. L., & Collins, S. D. (1988) · IEEE Transactions on Electron Devices · doi:10.1109/16.2532 · Cited by 58
Encapsulation of polymeric membrane-based ion-selective field effect transistors
Ho, N.-T., Kratochvil, J., Blackburn, G. F., & Janata, J. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85052-5 · Cited by 55
Dorvel, B. R., Reddy, B., Block, I. D., Mathias, P. C., Clare, S. E., Cunningham, B. T., Bergstrom, D. E., & Bashir, R. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200901688 · Cited by 52
Mixed metal oxide films as pH sensing materials
Gill, E., Arshak, K. I., Arshak, A., & Korostynska, O. (2007) · Microsystem Technologies · doi:10.1007/s00542-007-0435-9 · Cited by 52
A dipstick sensor for coulometric acid-base titrations
Olthuis, W., van der Schoot, B. H., Chavez, F., & Bergveld, P. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)80092-7 · Cited by 52
Chang, K., Chang, C.-T., Chao, K.-Y., & Lin, C. (2010) · Sensors · doi:10.3390/s100504643 · Cited by 54
“Schoning, M.J.; Brinkmann, D.; Rolka, D.; Demuth, C.; Poghossian, A. CIP (cleaning-in-place) suitable “non-glass” pH sensor based on a Ta2O5-gate EIS structure.”
BackgroundMethodInfluentialLong-life multiple-ISFETS with polymeric gates
Tsukada, K., Sebata, M., Miyahara, Y., & Miyagi, H. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87039-8 · Cited by 51
N-Channel field-effect transistors with floating gates for extracellular recordings
Meyburg, S., Goryll, M., Moers, J., Ingebrandt, S., Böcker-Meffert, S., Luth, H., & Offenhäusser, A. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.010 · Cited by 61
Monitoring soil pH variation using Polyaniline/SU-8 composite film based conductometric microsensor
Patil, S. J., Ghadi, H. J., Ramgir, N. S., Adhikari, A., & Rao, V. R. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.02.016 · Cited by 49
Fabrication and Characterization of a Ruthenium Nitride Membrane for Electrochemical pH Sensors
Liao, Y.-H., & Chou, J.-C. (2009) · Sensors · doi:10.3390/s90402478 · Cited by 51
The zeta potential of silicon nitride thin films
Bousse, L. J., & Mostarshed, S. (1991) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(91)85046-r · Cited by 49
Packaging technologies for integrated electrochemical sensors
Grisel, A., Francis, C., Verney, E., & Mondin, G. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)80093-9 · Cited by 48
Jang, H., & Cho, W.-J. (2011) · Applied Physics Letters · doi:10.1063/1.3619831 · Cited by 50
Kao, C. H., Chen, H., Kuo, L.-T., Wang, J., Chen, Y., Chu, Y.-C., Chen, C.-Y., Lai, C., Chang, S. W., & Chang, C. W. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.12.056 · Cited by 46
Kitagawa, Y., Tamiya, E., & Karube, I. (1987) · Analytical Letters · doi:10.1080/00032718708082238 · Cited by 46
Sharma, P., Gupta, S., Singh, R., Ray, K., Kothari, S. L., Sinha, S., Sharma, R., Mukhiya, R., Awasthi, K., & Kumar, M. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2019.07.252 · Cited by 46
Niwa, D., Omichi, K., Motohashi, N., Homma, T., & Ōsaka, T. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.11.055 · Cited by 54
Immobilization of E. coli bacteria in three-dimensional matrices for ISFET biosensor design
Bettaieb, F., Ponsonnet, L., Lejeune, P., Ouada, H. B., Martelet, C., Bakhrouf, A., Jaffrezic-Renault, N. J., & Othmane, A. (2007) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2007.02.004 · Cited by 45
Seki, A., Motoya, K., Watanabe, S., & Kubo, I. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00769-7 · Cited by 45
Electrolyte-Gated Graphene Ambipolar Frequency Multipliers for Biochemical Sensing
Fu, W., Feng, L., Mayer, D., Panaitov, G., Kireev, D., Offenhäusser, A., & Krause, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04729 · Cited by 44
High Performance of Silicon Nanowire-Based Biosensors using a High-k Stacked Sensing Thin Film
Bae, T.-E., Jang, H., Yang, J., & Cho, W.-J. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am401026z · Cited by 48
Yōshida, S., Hara, N., & Sugimoto, K. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1643074 · Cited by 47
Operation of an ISFET with non-insulated substrate directly exposed to the solution
Shulga, A., Netchiporouk, L. I., Sandrovsky, A. K., Abalov, A. A., Frolov, O. S., Kononenko, Y. G., Maupas, H., & Martelet, C. (1996) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)01760-s · Cited by 44
Chen, C.-C., Chen, H.-I., Liu, H.-Y., Chou, P.-C., Liou, J.-K., & Liu, W.-C. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.12.025 · Cited by 45
In vivo experiments with a pH-ISFET electrode
Schepel, S. J., de Rooij, N. F., Koning, G., Oeseburg, B., & Zijlstra, W. G. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443738 · Cited by 43
Vlasov, Y. G., Tarantov, Y., & Bobrov, P. V. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1957-3 · Cited by 46
Ion sensitive field effect transistor with amorphous tungsten trioxide gate for pH sensing
Chou, J.-C., & Chiang, J.-L. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00363-9 · Cited by 41
Silicon nanowire pH sensors fabricated with CMOS compatible sidewall mask technology
Zhou, K., Zhao, Z., Pan, L., & Wang, Z. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.114 · Cited by 40
Micro-Enzyme Electrode Prepared on Platinized Platinum
Ikariyama, Y., Yamauchi, S., Yukiashi, T., & Ushioda, H. (1987) · Analytical Letters · doi:10.1080/00032718708066322 · Cited by 40
pH-sensitive diamond field-effect transistors (FETs) with directly aminated channel surface
Song, K.-S., Nakamura, Y., Sasaki, Y., Degawa, M., Yang, J.-H., & Kawarada, H. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.051 · Cited by 39
FET‐Based Chemical Sensor Systems Fabricated with Standard Technologies
Errachid, A., Zine, N., Samitier, J., & Bausells, J. (2004) · Electroanalysis · doi:10.1002/elan.200403072 · Cited by 46
Microstructured solid-state ion-sensitive membranes by thermal oxidation of Ta
Gimmel, P., Schierbaum, K. D., Göpel†, W., van den Vlekkert, H. H., & de Rooij, N. F. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80227-q · Cited by 39
Ma, S., Li, X., Lee, Y.-K., & Zhang, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.061 · Cited by 40
Remedial and adaptive solutions of ISFET non‐ideal behaviour
Khanna, V. K. (2013) · Sensor Review · doi:10.1108/02602281311324681 · Cited by 38
Anzai, J., Hashimoto, J.-Y., Osa, T., & Matsuo, T. (1988) · Analytical Sciences · doi:10.2116/analsci.4.247 · Cited by 37
Self-citationAn Integrated Circuit for Chip-Based Analysis of Enzyme Kinetics and Metabolite Quantification
Cheah, B. C., Macdonald, A. I., Martin, C., Streklas, A., Campbell, G., Al-Rawhani, M. A., Nemeth, B., Grant, J. P., Barrett, M. P., & Cumming, D. R. S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2487603 · Cited by 37
“This low drift value allows this sensor to be used for stable assay measurements, unlike other ISFET devices which can suffer from significant levels of drift [17], [30], since our measurements only require 15 minutes to acquire sufficient enzyme response data.”
BackgroundMethodStudy of the pH-ISFET and EnFET for Biosensor Applications
Chiang, J.-L., Chou, J.-C., & Chen, Y. (2001) · Journal of Medical and Biological Engineering · Cited by 42
Study on the temperature effects of Al2O3 gate pH-ISFET
Chou, J.-C., Weng, C.-Y., & Tsai, H.-M. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00945-5 · Cited by 38
Biochemical sensors with structured and porous silicon capacitors
Luth, H., Thust, M., Steffen, A., Kordos, P., & Schöning, M. J. (2000) · Materials Science and Engineering B · doi:10.1016/s0921-5107(99)00275-5 · Cited by 36
الیاسی, ع., Fouladian, M., & Jamasb, S. (2018) · IEEE Journal of the Electron Devices Society · doi:10.1109/jeds.2018.2847740 · Cited by 36
“Although it has been reported that A12O3 does not hydrate [18], the time dependence of drift in A12O3-gate pH-sensitive ISFETs can also be explained in terms of a dispersive diffusion mechanism.”
BackgroundPan, T.-M., & Liao, K.-M. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.06.006 · Cited by 35
Performance and system-on-chip integration of an unmodified CMOS ISFET
Hammond, P. A., & Cumming, D. R. S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.065 · Cited by 37
Multi-enzyme electrode using hydrogen-ion-sensitive field-effect transistors
Hanazato, Y., Nakako, M., & Shiono, S. (1986) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1986.22435 · Cited by 35
Metadata
- Authors
- Matsuo, T., & Esashi, M.
- Affiliations
- Tohoku University (JP)
- Venue
- Sensors and Actuators
- Publisher
- Elsevier BV
- Published
- 1981-01
- Volume
- 1
- Pages
- 77-96
- ISSN
- 0250-6874 (ISSN-L)
- OpenAlex
- W2015173632
- Semantic Scholar
- 6134862a99965c7a0faf46c2239c8d5f39b93403
- Cited by
- 343
- References
- 14
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 12 · 2017: 10 · 2016: 11 · 2015: 10 · 2014: 10 · 2013: 10 · 2012: 10
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Sensors and Actuators (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Semiconductor materials and devices
- Keywords
- ion-sensitive field-effect transistor, ion-selective electrodes, IGFET, ion migration, electrolyte solutions, integrated circuit fabrication, biomedical sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.