The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field
Abstract
At high and medium magnetic field, the transverse NMR relaxation rate (T-1(2)) of water proteins in blood is determined predominantly by the oxygenation state of haemoglobin. T-1(2) depends quadratically on the field strength and on the proportion of haemoglobin that is deoxygenated. Deoxygenation increases the volume magnetic susceptibility within the erythrocytes and thus creates local field gradients around these cells. From volume susceptibility measurements and the dependence of T-1(2) on the pulse rate in the Carr-Purcell-Meiboom-Gill experiment, we show that the increase in T-1(2) with increasing blood deoxygenation arises from diffusion of water through these field gradients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“What causes the BOLD effect is the varying concentration of deoxygenated hemoglobin relative to the total hemoglobin that is either deoxygenated or oxygenated (123).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [123]
In the citing paper
“As a result, the concentration of deoxygenated hemoglobin decreases in capillary and venous vessels, reducing the paramagnetic susceptibility effect and thus increasing the T2*-weighted signal (123).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [123]
In the citing paper
“Because fMRI signal intensity is sensitive to the amount of oxygen carried by hemoglobin (5-7), this change in blood oxygen content at the site of increased brain activity can be detected with fMRI.”
From A default mode of brain function (2001) · cites this paper as [5]
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,239
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,001
High Resolution Nuclear Magnetic Resonance Spectroscopy
(1966) · Elsevier eBooks · doi:10.1016/c2013-0-05217-6 · Cited by 1,128
Luz, Z., & Meiboom, S. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734254 · Cited by 553
Biological Applications of Magnetic Resonance
(1979) · Elsevier eBooks · doi:10.1016/b978-0-126-40750-1.x5001-1 · Cited by 432
Examination of a Case of Suspected McArdle's Syndrome by31P Nuclear Magnetic Resonance
Ross, B. D., Radda, G. K., Gadian, D. G., Rocker, G. M., Esiri, M. M., & Smith, J. F. F. (1981) · New England Journal of Medicine · doi:10.1056/nejm198105283042206 · Cited by 427
Self-citationNuclear relaxation in macromolecules by paramagnetic ions: a novel mechanism
Guéron, M. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90029-3 · Cited by 327
Water diffusion permeability of erythrocytes using an NMR technique
Conlon, T., & Outhred, R. (1972) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(72)90256-8 · Cited by 272
Nuclear relaxation processes of paramagnetic complexes The slow-motion case
Vega, A. J., & Fiat, D. (1976) · Molecular Physics · doi:10.1080/00268977600100261 · Cited by 218
Nuclear-Magnetic-Resonance Study of Self-Diffusion in a Bounded Medium
Wayne, R. C., & Cotts, R. M. (1966) · Physical Review · doi:10.1103/physrev.151.264 · Cited by 186
Research works printed but not linked: 5
- Radda, 1981, J. Magn. Reson., 42, 488
- Gansse, 1980, Phil. Trans. R. Soc. Lond., B289, 438
- Gueron, 1975, J. Magn. Reson., 19, 58
- Packer, 1973, J. Magn. Reson., 9, 438
- Thulborn, 1981, J. Cereb. Blood Flow Metab., 1, S82
Cited by
Sorted by citations
Items 101–200 of 1,000
Imaging hippocampal function across the human life span: Is memory decline normal or not?
Small, S. A., Tsai, W. Y., DeLaPaz, R., Mayeux, R., & Stern, Y. (2002) · Annals of Neurology · doi:10.1002/ana.10105 · Cited by 205
Kiselev, V. G., Strecker, R., Ziyeh, S., Speck, O., & Hennig, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20383 · Cited by 201
Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan Methods
Glover, G. H., & Lee, A. T.-J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330507 · Cited by 200
High-Resolution MR Venography at 3.0 Tesla
Reichenbach, J. R., Barth, M., Haacke, E. M., Klarhöfer, M., Kaiser, W. A., & Moser, E. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200011000-00023 · Cited by 199
How accurate is magnetic resonance imaging of brain function?
Uǧurbil, K., Toth, L. J., & Kim, D. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(02)00039-5 · Cited by 198
The Statistical Analysis of Functional MRI Data
Lazar, N. A. (2008) · Statistics in the health sciences · doi:10.1007/978-0-387-78191-4 · Cited by 197
New frontiers and developing applications in 19F NMR
Yu, J.-X., Hallac, R. R., Chiguru, S., & Mason, R. P. (2012) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2012.10.001 · Cited by 198
Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans
Yacoub, E. S., de Moortele, P. V., Shmuel, A., & Uǧurbil, K. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.002 · Cited by 197
Contribution of Susceptibility-Weighted Imaging to Acute Stroke Assessment
Hermier, M., & Nighoghossian, N. (2004) · Stroke · doi:10.1161/01.str.0000133341.74387.96 · Cited by 192
Neurovascular Dysfunction in Vascular Dementia, Alzheimer's and Atherosclerosis
Shabir, O., Berwick, J., & Francis, S. E. (2018) · BMC Neuroscience · doi:10.1186/s12868-018-0465-5 · Cited by 191
In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T
Reeder, S. B., Faranesh, A. Z., Boxerman, J. L., & McVeigh, E. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390617 · Cited by 189
Functional Magnetic Resonance Imaging with Echo Planar Imaging
Kwong, K. K. (1996) · Springer eBooks · doi:10.1007/978-88-470-2194-5_16 · Cited by 184
On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
Kiselev, V. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1307 · Cited by 181
Clinical applications of susceptibility weighted MR imaging of the brain – a pictorial review
Thomas, B., Somasundaram, S., Thamburaj, K., Kesavadas, C., Gupta, A. K., Bodhey, N. K., & Kapilamoorthy, T. R. (2007) · Neuroradiology · doi:10.1007/s00234-007-0316-z · Cited by 180
Effect of oxygen inhalation on relaxation times in various tissues
Tadamura, E., Hatabu, H., Li, W., Prasad, P. V., & Edelman, R. R. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070134 · Cited by 178
Age-related Reduction in Functional MRI Response to Photic Stimulation
Ross, M. H., Yurgelun-Todd, D. A., Renshaw, P. F., Maas, L. C., Mendelson, J. H., Mello, N. K., Cohen, B., & Levin, J. M. (1997) · Neurology · doi:10.1212/wnl.48.1.173 · Cited by 174
Combined imaging–histological study of cortical laminar specificity of fMRI signals
Harel, N., Lin, J., Moeller, S., Uǧurbil, K., & Yacoub, E. S. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.016 · Cited by 169
Imaging tumour hypoxia with oxygen-enhanced MRI and BOLD MRI
O’Connor, J. P. B., Robinson, S. P., & Waterton, J. C. (2018) · British Journal of Radiology · doi:10.1259/bjr.20180642 · Cited by 176
Self-citationImaging of Acute Cerebral Ischemia
Beauchamp, N. J., Barker, P. B., Wang, P. Y., & van Zijl, P. C. M. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au16307 · Cited by 168
Theory, Instrumentation, and Applications of Electron Paramagnetic Resonance Oximetry
Ahmad, R., & Kuppusamy, P. (2010) · Chemical Reviews · doi:10.1021/cr900396q · Cited by 174
Quantitative oxygenation venography from MRI phase
Fan, A. P., Bilgiç, B., Gagnon, L., Witzel, T., Bhat, H., Rosen, B. R., & Elfar Adalsteinsson, A. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24918 · Cited by 166
Bolar, D. S., Rosen, B. R., Sorensen, A. G., & Elfar Adalsteinsson, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22946 · Cited by 164
The investigation of functional brain lateralization by transcranial Doppler sonography
Deppe, M., Ringelstein, E. B., & Knecht, S. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.10.016 · Cited by 162
Functional mapping in the human brain using high magnetic fields
Uǧurbil, K., Hu, X. P., Chen, W., Zhu, X.-H., Kim, S., & Georgopoulos, A. P. (1999) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1999.0474 · Cited by 153
Detecting activity-evoked pH changes in human brain
Magnotta, V. A., Heo, H., Dlouhy, B. J., Dahdaleh, N. S., Follmer, R. L., Thedens, D. R., Welsh, M. J., & Wemmie, J. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205902109 · Cited by 151
MRI contrast agents based on dysprosium or holmium
Norek, M., & Peters, J. A. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.08.002 · Cited by 150
Validation of oxygen extraction fraction measurement by qBOLD technique
He, X., Zhu, M., & Yablonskiy, D. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21719 · Cited by 150
Yablonskiy, D. A., Sukstanskii, A. L., & He, X. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2839 · Cited by 148
Rich, L. J., & Seshadri, M. (2014) · Radiology · doi:10.1148/radiol.14140654 · Cited by 145
Thulborn, K. R., & Ackerman, J. J. H. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90118-x · Cited by 143
Self-citationSadowski, E. A., Fain, S. B., Alford, S. K., Korosec, F. R., Fine, J. P., Muehrer, R. J., Djamali, A., Hofmann, R. M., Becker, B. N., & Grist, T. M. (2005) · Radiology · doi:10.1148/radiol.2363041080 · Cited by 142
Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths
Dobre, M. C., Uǧurbil, K., & Marjańska, M. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.10.020 · Cited by 141
Blockley, N. P., Jiang, L., Gardener, A. G., Ludman, C. N., Francis, S., & Gowland, P. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21792 · Cited by 140
Physiological measurements using ultra-high field fMRI: a review
Francis, S., & Sánchez-Panchuelo, R.-M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/r167 · Cited by 142
An, H., & Lin, W. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10576 · Cited by 138
Functional magnetic resonance imaging of the human brain
Kim, S., & Uǧurbil, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02252-8 · Cited by 138
Effects of hematocrit and oxygen saturation level on blood spin‐lattice relaxation
Silvennoinen, M. J., Kettunen, M. I., & Kauppinen, R. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10370 · Cited by 136
Magnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
Cerebrovascular Dynamics of Autoregulation and Hypoperfusion
Zaharchuk, G., Mandeville, J. B., Bogdanov, A. A., Jr., Weissleder, R., Rosen, B. R., & Marota, J. J. A. (1999) · Stroke · doi:10.1161/01.str.30.10.2197 · Cited by 136
MR detection of hyperacute parenchymal hemorrhage of the brain.
Atlas, S. W., & Thulborn, K. R. (1998) · PubMed Central · Cited by 136
Self-citationHyperpolarised xenon in biology
Cherubini, A., & Bifone, A. (2003) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(02)00052-3 · Cited by 130
Yamamoto, T., & Kato, T. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/7/309 · Cited by 129
Magnetic Resonance Imaging Mapping of Brain Function: Human Visual Cortex
Belliveau, J. W., Kwong, K. K., Kennedy, D. N., BAKER, J. R., Stern, C. E., Benson, R. R., Chesler, D. A., Weisskoff, R. M., Cohen, M. S., Tootell, R. B. H., et al. (1992) · Investigative Radiology · doi:10.1097/00004424-199212002-00011 · Cited by 128
The evolution of acute stroke recorded by multimodal magnetic resonance imaging
Quast, M. J., Huang, N., Hillman, G. R., & Kent, T. A. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90465-p · Cited by 128
New magnetic resonance contrast agents as biochemical reporters
Meade, T. J., Taylor, A. K., & Bull, S. R. (2003) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2003.09.009 · Cited by 127
An, H., & Lin, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10148 · Cited by 126
Functional Magnetic Resonance Imaging
Segebarth, C. M., & Décorps, M. (2009) · Tomography · doi:10.1002/9780470611784.ch15 · Cited by 126
Micromagnetic resonance relaxometry for rapid label-free malaria diagnosis
Peng, W. K., Kong, T. F., Ng, C. S., Chen, L., Huang, Y., Bhagat, A. A. S., Nguyen, N., Preiser, P. R., & Han, J. (2014) · Nature Medicine · doi:10.1038/nm.3622 · Cited by 124
Djamali, A., Sadowski, E. A., Muehrer, R. J., Reese, S. R., Smavatkul, C., Vidyasagar, A., Fain, S. B., Lipscomb, R. C., Hullett, D. H., Samaniego-Picota, M., et al. (2006) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00222.2006 · Cited by 124
The measurement of diffusion and perfusion in biological systems using magnetic resonance imaging
Thomas, D. L., Lythgoe, M. F., Pell, G. S., Calamante, F., & Ordidge, R. J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/8/201 · Cited by 123
Diffusion measurements in intracranial hematomas: implications for MR imaging of acute stroke.
Atlas, S. W., DuBois, P., Singer, M. B., & Lu, D. (2000) · PubMed Central · Cited by 123
Saeed, M., Wendland, M. F., Masui, T., & Higgins, C. B. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310105 · Cited by 122
The human red nucleus and lateral cerebellum in supporting roles for sensory information processing
Liu, Y., Pu, Y., Gao, J., Parsons, L. M., Xiong, J., Mario Liotti, A., Bower, J. M., & Fox, P. T. (2000) · Human Brain Mapping · doi:10.1002/1097-0193(200008)10:4 · Cited by 76
Consensus-based technical recommendations for clinical translation of renal BOLD MRI
Bane, O., Mendichovszky, I. A., Milani, B., Dekkers, I. A., Deux, J., Eckerbom, P., Grenier, N., Hall, M. E., Inoue, T., Laustsen, C., et al. (2019) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-019-00802-x · Cited by 120
Reduction in BOLD fMRI response to primary visual stimulation following alcohol ingestion
Levin, J. M., Ross, M. H., Mendelson, J. H., Kaufman, M. J., LANGE, N. D., Maas, L. C., Mello, N. K., Cohen, B. M., & Renshaw, P. F. (1998) · Psychiatry Research Neuroimaging · doi:10.1016/s0925-4927(98)00022-5 · Cited by 119
Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
Barth, M., & Moser, E. (1997) · PubMed · Cited by 118
Golay, X., Silvennoinen, M. J., Zhou, J., Clingman, C. S., Kauppinen, R. A., Pekar, J. J., & van Zijl, P. C. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1189 · Cited by 118
Spreading Waves of a Reduced Diffusion Coefficient of Water in Normal and Ischemic Rat Brain
Hasegawa, Y., Latour, L. L., Formato, J. E., Sotak, C. H., & Fisher, M. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.23 · Cited by 116
Jain, V., Abdulmalik, O. Y., PROPERT, K. J., & Wehrli, F. W. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23282 · Cited by 113
Lu, H., & van Zijl, P. C. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20379 · Cited by 114
The functional basis of ocular dominance: functional MRI (fMRI) findings
Rombouts, S. A. R. B., Barkhof, F., Sprenger, M., Valk, J., & Scheltens, P. (1996) · Neuroscience Letters · doi:10.1016/s0304-3940(96)13260-2 · Cited by 112
Event-related fMRI contrast when using constant interstimulus interval: Theory and experiment
Bandettini, P. A., & Cox, R. W. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200004)43:4 · Cited by 230
High-resolution venography of the brain using magnetic resonance imaging
Reichenbach, J. R., Essig, M., Haacke, E. M., Lee, B. C., Przetak, C., Kaiser, W. A., & Schad, L. R. (1998) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02662513 · Cited by 110
Measurement of regional blood oxygenation and cerebral hemodynamics
Hoppel, B. E., Weisskoff, R. M., Thulborn, K. R., Moore, J. B., Kwong, K. K., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300609 · Cited by 110
Self-citationTumour dose response to the antivascular agent ZD6126 assessed by magnetic resonance imaging
Robinson, S. P., McIntyre, D. J. O., Checkley, D., Tessier, J. J. L., Howe, F. A., Griffiths, J. R., Ashton, S., Ryan, A. J., Blakey, D. C., & Waterton, J. C. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6600926 · Cited by 109
Self-citationHaacke, E. M., Lai, S., Yablonskiy, D. A., & Lin, W. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060204 · Cited by 109
Dynamic oxygen‐enhanced MRI reflects diffusing capacity of the lung
Ohno, Y., Hatabu, H., Takenaka, D., CAUTEREN, M. V., Fujii, M., & Sugimura, K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10168 · Cited by 108
Negative Dip in BOLD fMRI Is Caused by Blood Flow— Oxygen Consumption Uncoupling In Humans
Röther, J., Knab, R., Hamzei, F., Fiehler, J., Reichenbach, J. R., Büchel, C., & Weiller, C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0965 · Cited by 108
Markl, M., & Leupold, J. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23638 · Cited by 107
Brain water diffusion in normal and creatine-supplemented rats during transient global ischemia
Wick, M., Fujimori, H., Michaelis, T., & Frahm, J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4 · Cited by 25
Anatomical and Functional Evaluation of Pulmonary Veins in Children by Magnetic Resonance Imaging
Grosse‐Wortmann, L., Alotay, A., Goo, H. W., Macgowan, C. K., Coles, J. G., Benson, L. N., Redington, A. N., & Yoo, S. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.09.052 · Cited by 107
Determination of Oxygen Extraction Ratios by Magnetic Resonance Imaging
Oja, J. M. E., GILLEN, J. S., Kauppinen, R. A., Kraut, M. A., & van Zijl, P. C. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199912000-00001 · Cited by 106
Schwarzbauer, C., Morrissey, S., & Haase, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350413 · Cited by 106
Oxygen-Enhanced MR Ventilation Imaging of the Lung
Ohno, Y., Hatabu, H., Takenaka, D., Adachi, S., CAUTEREN, M. V., & Sugimura, K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.1.1770185 · Cited by 105
Tsui, Y., Tsai, F. Y., Hasso, A. N., Greensite, F. S., & Nguyen, B. V. (2009) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2009.08.064 · Cited by 104
Cognitive Neuroscience Studies of the Chinese Language
Kao, H. S. R., Leong, C.-K., & Gao, D. (2002) · Hong Kong University Press eBooks · doi:10.1515/9789882200777 · Cited by 104
fMRI at 20: Has it changed the world?
Rosen, B. R., & Savoy, R. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.004 · Cited by 108
Yu, X., Glen, D., Wang, S., Dodd, S. J., Hirano, Y., Saad, Z. S., Reynolds, R. C., Silva, A. C., & Koretsky, A. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.001 · Cited by 98
Ge, Y., Zhang, Z., Lu, H., Tang, L., Jaggi, H., Herbert, J., Babb, J. S., Rusinek, H., & Grossman, R. I. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.191 · Cited by 104
Heß, A., Stiller, D., Kaulisch, T., Heil, P. F., & Scheich, H. (2000) · Journal of Neuroscience · doi:10.1523/jneurosci.20-09-03328.2000 · Cited by 102
Glover, G. H., Lemieux, S. K., Drangova, M., & Pauly, J. M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350306 · Cited by 99
A new NOE-mediated MT signal at around −1.6ppm for detecting ischemic stroke in rat brain
Zhang, X., Wang, F., Afzal, A., Xu, J., Gore, J. C., Gochberg, D. F., & Zu, Z. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.05.002 · Cited by 98
Blood oxygen saturation assessment in vivo using T2 * estimation
Li, D., Wang, Y., & Waight, D. J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390503 · Cited by 98
Andreas, M., Schmid, A. I., Keilani, M. Y., Doberer, D., Bartko, J., Crevenna, R., Moser, E., & Wolzt, M. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-32 · Cited by 98
A Bayesian Time-Course Model for Functional Magnetic Resonance Imaging Data
Genovese, C. R. (2000) · Journal of the American Statistical Association · doi:10.1080/01621459.2000.10474253 · Cited by 98
Bulte, J. W. M., Miller, G., Vymazal, J., Brooks, R. A., & Frank, J. A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370409 · Cited by 98
Stables, L. A., Kennan, R. P., & Gore, J. C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400314 · Cited by 97
Han, F., Xiao, W., Xu, Y., Wu, J., Wang, Q., Wang, H., Zhang, M., & Chen, J. (2008) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn064 · Cited by 97
Quantitative assessment of blood inflow effects in functional MRI signals
Gao, J., Miller, I., Lai, S., Xiong, J., & Fox, P. T. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360219 · Cited by 97
Zhong, J., Kennan, R. P., Fulbright, R. K., & Gore, J. C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400405 · Cited by 97
Real‐time observation of transient focal ischemia and hyperemia in cat brain
de Crespigny, A. J., Wendland, M. F., Derugin, N., Koźniewska, E., & Moseley, M. E. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270220 · Cited by 94
Apparent diffusion tensor measurements in myelin-deficient rat spinal cords
Gulani, V., WEBB, A. G., Duncan, I. D., & Lauterbur, P. C. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2 · Cited by 250
Quantification of regional blood volumes by rapid T1 mapping
Schwarzbauer, C., Syha, J., & Haase, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290521 · Cited by 96
Brooks, D. J., Luthert, P. J., Gadian, D. G., & MARSDEN, C. D. (1989) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.1.108 · Cited by 95
Phase‐based regional oxygen metabolism (PROM) using MRI
Fan, A. P., Benner, T., Bolar, D. S., Rosen, B. R., & Elfar Adalsteinsson, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23050 · Cited by 94
Posse, S., Kemna, L., Elghahwagi, B., Wiese, S., & Kiselev, V. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1187 · Cited by 93
Zhu, X., & Chen, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1267 · Cited by 92
Methods for Noninvasive Imaging of Tissue Hypoxia
Vikram, D. S., Zweier, J. L., & Kuppusamy, P. (2007) · Antioxidants and Redox Signaling · doi:10.1089/ars.2007.1717 · Cited by 92
Renal Functional MRI: Are We Ready for Clinical Application?
Chandarana, H., & Lee, V. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2390 · Cited by 92
Noguchi, K., Seto, H., Kamisaki, Y., Tomizawa, G., Toyoshima, S., & Watanabe, N. (2000) · PubMed Central · Cited by 91
Metadata
- Authors
- Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K.
- Affiliations
- University of Oxford (GB)
- Venue
- Biochimica et Biophysica Acta (BBA) - General Subjects
- Publisher
- Elsevier BV
- Published
- 1982-02
- Volume
- 714
- Issue
- 2
- Pages
- 265-270
- ISSN
- 0304-4165 (ISSN-L)
- OpenAlex
- W1980086703
- Cited by
- 1,134
- References
- 22
- Citations by year
- 2026: 8 · 2025: 15 · 2024: 20 · 2023: 30 · 2022: 16 · 2021: 22 · 2020: 25 · 2019: 19 · 2018: 15 · 2017: 22 · 2016: 37 · 2015: 37 · 2014: 34 · 2013: 30 · 2012: 47
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biochimica et Biophysica Acta (BBA) - General Subjects (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Keywords
- T2 relaxation, water protons, whole blood, hemoglobin oxygenation, volume magnetic susceptibility, erythrocytes, diffusion, high magnetic fields, NMR relaxation
- MeSH terms
- Animals, Body Water, Erythrocytes, Hematocrit, Hemoglobins, Male, Magnetic Resonance Spectroscopy, Oxygen, Protons, Rabbits, Rats, Inbred Strains, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review