Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistical Methods
(1999) · Technometrics · doi:10.1080/00401706.1999.10485954 · Cited by 6,090
Nonparametric Statistical Methods.
Moore, D. S., Hollander, M., & Wolfe, D. A. (1974) · Journal of the American Statistical Association · doi:10.2307/2285701 · Cited by 2,857
Adult Norms for the Box and Block Test of Manual Dexterity
Mathiowetz, V., Volland, G., Kashman, N., & Weber, K. (1985) · The American Journal of Occupational Therapy · doi:10.5014/ajot.39.6.386 · Cited by 2,105
An objective and standardized test of hand function.
Jebsen, R. H., Taylor, N. F., Trieschmann, R. B., Trotter, M. J., & Howard, L. (1969) · PubMed · Cited by 1,705
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
Adult Norms for the Nine Hole Peg Test of Finger Dexterity
Mathiowetz, V., Weber, K., Kashman, N., & Volland, G. (1985) · The Occupational Therapy Journal of Research · doi:10.1177/153944928500500102 · Cited by 972
Observations are always ordinal; measurements, however, must be interval.
Wright, B., & Linacre, J. M. (1989) · PubMed · Cited by 679
Ordinal scales and foundations of misinference.
Merbitz, C. T., Morris, J., & Grip, J. C. (1989) · PubMed · Cited by 548
A quantitative test of upper extremity function
Carroll, D. (1965) · Journal of Chronic Diseases · doi:10.1016/0021-9681(65)90030-5 · Cited by 345
Rehabilitation of the hand : surgery and therapy
Hunter, J. M., Scheiner, L. H., & Mackin, E. J. (1990) · Medical Entomology and Zoology · Cited by 339
Cited by
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Sollerman Hand Function Test: A Standardised Method and its Use in Tetraplegic Patients
Sollerman, C., & Ejeskär, A. (1995) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844319509034334 · Cited by 457
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Self-citationProchazka, A., Gauthier, M., Wieler, M., & Kenwell, Z. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90426-3 · Cited by 250
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationAn Implanted Upper-Extremity Neuroprosthesis Using Myoelectric Control
Kilgore, K. L., Hoyen, H. A., Bryden, A. M., Hart, R. L., Keith, M. W., & Peckham, P. H. (2008) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2008.01.007 · Cited by 189
Self-citationIdentification of key pinch forces required to complete functional tasks
Smaby, N., Johanson, M. E., Baker, B., Kenney, D. E., Murray, W. M., & Hentz, V. R. (2004) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2004.02.0215 · Cited by 171
“Measurements of pinch force magnitude (recorded using a clinical pinch meter) [5–9], patient satisfaction surveys and questionnaires [5,6,10,11], and clinical dexterity tests, such as the Jebsen and Sollerman tests [12–14], provide”
MethodSchwemmer, M. A., Skomrock, N. D., Sederberg, P. B., Ting, J. E., Sharma, G., Bockbrader, M. A., & Friedenberg, D. A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0171-y · Cited by 163
Restoring the Sense of Touch Using a Sensorimotor Demultiplexing Neural Interface
Ganzer, P. D., Colachis, S. C., Schwemmer, M. A., Friedenberg, D. A., Dunlap, C. F., Swiftney, C. E., Jacobowitz, A. F., Weber, D. J., Bockbrader, M. A., & Sharma, G. (2020) · Cell · doi:10.1016/j.cell.2020.03.054 · Cited by 156
Implanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia
Memberg, W. D., Polasek, K. H., Hart, R. L., Bryden, A. M., Kilgore, K. L., Nemunaitis, G. A., Hoyen, H. A., Keith, M. W., & Kirsch, R. F. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.01.028 · Cited by 137
Self-citation“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97
Implanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
“Outcome studies demonstrated significant improvements in impairment [24,25], and disability [13,26–28] measures, and FDA approval was received in 1997.”
BackgroundSelf-citationRupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“a glass cylinder as part of the Grasp-and-Release Test (GRT) [33].”
MethodSatisfaction with and usage of a hand neuroprosthesis
Wuolle, K. S., Van Doren, C. L., Bryden, A. M., Hunter Peckham, P., Keith, M. W., Kilgore, K. L., & Grill, J. H. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90123-5 · Cited by 70
Self-citation
Metadata
- Authors
- Wuolle, K. S., Van Doren, C. L., Thrope, G. B., Keith, M. W., & Peckham, P. H.
- Venue
- The Journal of Hand Surgery
- Publisher
- Elsevier BV
- Published
- 1994-03
- Volume
- 19
- Issue
- 2
- Pages
- 209-218
- ISSN
- 0363-5023 (ISSN-L)
- OpenAlex
- W2010158783
- Cited by
- 198
- References
- 25
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.