Restoring the Sense of Touch Using a Sensorimotor Demultiplexing Neural Interface
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Some neurotech devices are beginning to restore movement and sensation in people with missing or damaged limbs, spinal cord severation, or sensory loss/impairments.
“Some neurotech devices are beginning to restore movement and sensation in people with missing or damaged limbs; 38 spinal cord severation; 14 or those with sensory loss, impairments, or differences that individuals want to improve—for example, cochlear implants for deafness 7 or retinal implants for certain kinds of visual impairments. 5”
From AI and Neurotechnology (2023) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
International standards for neurological classification of spinal cord injury (Revised 2011)
Kirshblum, S. C., Burns, S. P., Biering-Sorensen, F., Donovan, W., Graves, D. E., Jha, A., Johansen, M., Jones, L., Krassioukov, A., Mulcahey, M. J., et al. (2011) · The Journal of Spinal Cord Medicine · doi:10.1179/204577211x13207446293695 · Cited by 2,327 · see citing works
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
Self-citationNeural constraints on learning
Sadtler, P. T., Quick, K. M., Golub, M. D., Chase, S. M., Ryu, S. I., Tyler-Kabara, E. C., Yu, B. M., & Batista, A. P. (2014) · Nature · doi:10.1038/nature13665 · Cited by 713 · see citing works
A brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635 · see citing works
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617 · see citing works
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368 · see citing works
Jarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340 · see citing works
Oscillatory multiplexing of population codes for selective communication in the mammalian brain
Akam, T., & Kullmann, D. M. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3668 · Cited by 327 · see citing works
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · see citing works
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · see citing works
Flagged first, then by citations
Research works printed but not linked: 63
- [1]1. Ackerley, R. ∙ Kavounoudias, A. The role of tactile afference in shaping motor behaviour and implications for prosthetic innovation Neuropsychologia. 2015; 79:192-205 Crossref Scopus (60) PubMed Google Scholar
- [2]2. Ajiboye, A.B. ∙ Willett, F.R. ∙ Young, D.R. ... Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration Lancet. 2017; 389:1821-1830 Full Text Full Text (PDF) Scopus (509) PubMed Google Scholar
- [4]4. Anderson, K.D. Targeting recovery: priorities of the spinal cord-injured population J. Neurotrauma. 2004; 21:1371-1383 Crossref Scopus (1489) PubMed Google Scholar
- [5]5. Annetta, N.V. ∙ Friend, J. ∙ Schimmoeller, A. ... A High Definition Noninvasive Neuromuscular Electrical Stimulation System for Cortical Control of Combinatorial Rotary Hand Movements in a Human With Tetraplegia IEEE Trans. Biomed. Eng. 2019; 66:910-919 Crossref Scopus (24) PubMed Google Scholar
- [6]6. Armenta Salas, M. ∙ Bashford, L. ∙ Kellis, S. ... Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation eLife. 2018; 7:1-11 Crossref Scopus (144) Google Scholar
- [7]7. Awad, A. ∙ Levi, R. ∙ Lindgren, L. ... Preserved somatosensory conduction in a patient with complete cervical spinal cord injury J. Rehabil. Med. 2015; 47:426-431 Crossref Scopus (12) PubMed Google Scholar
- [9]9. Blabe, C.H. ∙ Gilja, V. ∙ Chestek, C.A. ... Assessment of brain-machine interfaces from the perspective of people with paralysis J. Neural Eng. 2015; 12:043002 Crossref Scopus (76) PubMed Google Scholar
- [10]10. Bockbrader, M.A. ∙ Francisco, G. ∙ Lee, R. ... Brain Computer Interfaces in Rehabilitation Medicine PM&R. 2018; 10:S233-S243 Crossref Scopus (61) PubMed Google Scholar
- [11]11. Bockbrader, M. ∙ Annetta, N. ∙ Friedenberg, D. ... Clinically significant gains in skillful grasp coordination by an individual with tetraplegia using an implanted brain-computer interface with forearm transcutaneous muscle stimulation Arch. Phys. Med. Rehabil. 2019; 100:30163-30167 Full Text Full Text (PDF) Scopus (31) Google Scholar
- [12]12. Borton, D. ∙ Bonizzato, M. ∙ Beauparlant, J. ... Corticospinal neuroprostheses to restore locomotion after spinal cord injury Neurosci. Res. 2014; 78:21-29 Crossref Scopus (43) PubMed Google Scholar
- [13]13. Bouton, C.E. ∙ Shaikhouni, A. ∙ Annetta, N.V. ... Restoring cortical control of functional movement in a human with quadriplegia Nature. 2016; 533:247-250 Crossref Scopus (602) PubMed Google Scholar
- [14]14. Caldwell, D.J. ∙ Cronin, J.A. ∙ Wu, J. ... Direct stimulation of somatosensory cortex results in slower reaction timescompared to peripheral touch in humans Sci. Rep. 2019; 9:1-11 PubMed Google Scholar
- [16]16. Chatterjee, A. ∙ Aggarwal, V. ∙ Ramos, A. ... A brain-computer interface with vibrotactile biofeedback for haptic information J. Neuroeng. Rehabil. 2007; 4:40 Crossref Scopus (154) PubMed Google Scholar
- [17]17. Chang, C.C. ∙ Lin, C.J. LIBSVM: a library for support vector machines. ACM Transactions on Intelligent Systems and Technology, 2011 2:27:1-27:27 Software available at https://www.csie.ntu.edu.tw/∼cjlin/libsvm Google Scholar
- [18]18. Colachis, 4th, S.C. ∙ Bockbrader, M.A. ∙ Zhang, M. ... Dexterous Control of Seven Functional Hand Movements Using Cortically-Controlled Transcutaneous Muscle Stimulation in a Person With Tetraplegia Front. Neurosci. 2018; 12:208 Crossref Scopus (39) PubMed Google Scholar
- [20]20. Collinger, J.L. ∙ Gaunt, R.A. ∙ Schwartz, A.B. Progress towards restoring upper limb movement and sensation through intracortical brain-computer interfaces Curr. Opin. Biomed. Eng. 2018; 8:84-92 Crossref Scopus (25) Google Scholar
- [21]21. Darie, R. ∙ Powell, M. ∙ Borton, D. Delivering the Sense of Touch to the Human Brain Neuron. 2017; 93:728-730 Full Text Full Text (PDF) Scopus (6) PubMed Google Scholar
- [22]22. Dimitrijevic, M.R. Neurophysiology in spinal cord injury Paraplegia. 1987; 25:205-208 Crossref Scopus (38) PubMed Google Scholar
- [23]23. Downey, J.E. ∙ Schwed, N. ∙ Chase, S.M. ... Intracortical recording stability in human brain-computer interface users J. Neural Eng. 2018; 15:046016 Crossref Scopus (75) PubMed Google Scholar
- [24]24. Finnerup, N.B. ∙ Gyldensted, C. ∙ Fuglsang-Frederiksen, A. ... Sensory perception in complete spinal cord injury Acta Neurol. Scand. 2004; 109:194-199 Crossref Scopus (60) PubMed Google Scholar
- [25]25. Flesher, S.N. ∙ Collinger, J.L. ∙ Foldes, S.T. ... Intracortical microstimulation of human somatosensory cortex Sci. Transl. Med. 2016; 8:361ra141 Crossref Scopus (451) PubMed Google Scholar
- [26]26. Flesher, S.N. ∙ Downey, J. ∙ Collinger, J. ... Intracortical microstimulation as a feedback source forbrain-computer interface users Guger, C. ∙ Allison, B. ∙ Lebedev, M. (Editors) Brain-Computer Interface Research. Springer Briefs in Electrical and Computer Engineering Springer, 2017; 43-54 Crossref Google Scholar
- [27]27. Flesher, S.N. ∙ Downey, J.E. ∙ Weiss, J.M. ... Restored tactile sensation improves neuroprosthetic arm control bioRxiv. 2019; Crossref Scopus (0) Google Scholar
- [28]28. Friedenberg, D.A. ∙ Bouton, C.E. ∙ Annetta, N.V. ... Big data challenges in decoding cortical activity in a human with quadriplegia to inform a brain computer interface Conf. Proc. IEEE Eng. Med. Biol. Soc. 2016; 2016:3084-3087 PubMed Google Scholar
- [29]29. Friedenberg, D.A. ∙ Schwemmer, M.A. ∙ Landgraf, A.J. ... Neuroprosthetic-enabled control of graded arm muscle contraction in a paralyzed human Sci. Rep. 2017; 7:8386 Crossref Scopus (50) PubMed Google Scholar
- [30]30. Ganzer, P.D. ∙ Moxon, K.A. ∙ Knudsen, E.B. ... Serotonergic pharmacotherapy promotes cortical reorganization after spinal cord injury Exp. Neurol. 2013; 241:84-94 Crossref Scopus (26) PubMed Google Scholar
- [31]31. Ganzer, P.D. ∙ Manohar, A. ∙ Shumsky, J.S. ... Therapy induces widespread reorganization of motor cortex after complete spinal transection that supports motor recovery Exp. Neurol. 2016; 279:1-12 Crossref Scopus (17) PubMed Google Scholar
- [32]32. Geyer, S. ∙ Luppino, G. ∙ Rozzi, S. Motor cortex Mai, J. ∙ Paxinos, G. (Editors) The Humannervous System Elsevier, 2012; 1074-1109 Crossref Scopus (15) Google Scholar
- [33]33. Gilja, V. ∙ Pandarinath, C. ∙ Blabe, C.H. ... Clinical translation of a high-performance neural prosthesis Nat. Med. 2015; 21:1142-1145 Crossref Scopus (223) PubMed Google Scholar
- [34]34. Godlove, J.M. ∙ Whaite, E.O. ∙ Batista, A.P. Comparing temporal aspects of visual, tactile, and microstimulation feedback for motor control J. Neural Eng. 2014; 11:046025 Crossref Scopus (25) PubMed Google Scholar
- [35]35. Goldring, S. ∙ Ratcheson, R. Human motor cortex: sensory input data from single neuron recordings Science. 1972; 175:1493-1495 Crossref Scopus (100) PubMed Google Scholar
- [36]36. Harding-Forrester, S. ∙ Feldman, D.E. Somatosensory maps Handb. Clin. Neurol. 2018; 151:73-102 Crossref Scopus (35) PubMed Google Scholar
- [37]37. Hari, R. ∙ Forss, N. ∙ Avikainen, S. ... Activation of human primary motor cortex during action observation: a neuromagnetic study Proc. Natl. Acad. Sci. USA. 1998; 95:15061-15065 Crossref Scopus (785) PubMed Google Scholar
- [38]38. Hatsopoulos, N.G. ∙ Suminski, A.J. Sensing with the motor cortex Neuron. 2011; 72:477-487 Full Text Full Text (PDF) Scopus (116) PubMed Google Scholar
- [40]40. Ibáñez, V. ∙ Deiber, M.P. ∙ Sadato, N. ... Effects of stimulus rate on regional cerebral blood flow after median nerve stimulation Brain. 1995; 118:1339-1351 Crossref Scopus (97) PubMed Google Scholar
- [41]41. Ioannides, A.A. ∙ Liu, L. ∙ Khurshudyan, A. ... Brain activation sequences following electrical limb stimulation of normal and paraplegic subjects Neuroimage. 2002; 16:115-129 Crossref Scopus (13) PubMed Google Scholar
- [44]44. Johnson, L.A. ∙ Wander, J.D. ∙ Sarma, D. ... Direct electrical stimulation of the somatosensory cortex in humans using electrocorticography electrodes: a qualitative and quantitative report J. Neural Eng. 2013; 10:036021 Crossref Scopus (82) PubMed Google Scholar
- [45]45. Kaas, J.H. Somatosensory system Mai, J. ∙ Paxinos, G. (Editors) The Human Nervous System Elsevier, 2012; 1074-1109 Crossref Scopus (44) Google Scholar
- [46]46. Kalra, M. ∙ Rakheja, S. ∙ Marcotte, P. ... Measurement of coupling forces at the power tool handle-hand interface Int. J. Ind. Ergon. 2015; 50:105-120 Crossref Scopus (25) Google Scholar
- [48]48. Kao, K. ∙ Huang, J. ∙ Pan, M. Design and Implementation of Assistive Devices for Poststroke Rehabilitation of Hand and Fingers J. Med. Device. 2014; 8:020933 Crossref Scopus (2) Google Scholar
- [50]50. Kirshblum, S.C. ∙ Biering-Sorensen, F. ∙ Betz, R. ... International Standards for Neurological Classification of Spinal Cord Injury: cases with classification challenges J. Spinal Cord Med. 2014; 37:120-127 Crossref Scopus (68) PubMed Google Scholar
- [51]51. Kumar, N. ∙ Manjaly, J.A. ∙ Miyapuram, K.P. Feedback about action performed can alter the sense of self-agency Front. Psychol. 2014; 5:145 Crossref Scopus (6) PubMed Google Scholar
- [52]52. Kurth, R. ∙ Villringer, K. ∙ Mackert, B.M. ... fMRI assessment of somatotopy in human Brodmann area 3b by electrical finger stimulation Neuroreport. 1998; 9:207-212 Crossref Scopus (124) PubMed Google Scholar
- [53]53. Lebedev, M.A. ∙ Nicolelis, M.A.L. Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation Physiol. Rev. 2017; 97:767-837 Crossref Scopus (339) PubMed Google Scholar
- [54]54. Lee, M.W. ∙ McPhee, R.W. ∙ Stringer, M.D. An evidence-based approach to human dermatomes Clin. Anat. 2008; 21:363-373 Crossref Scopus (144) PubMed Google Scholar
- [55]55. Manohar, A. ∙ Foffani, G. ∙ Ganzer, P.D. ... Cortex-dependent recovery of unassisted hindlimb locomotion after complete spinal cord injury in adult rats eLife. 2017; 6:e23532 Crossref Scopus (28) PubMed Google Scholar
- [57]57. Meek, S.G. ∙ Jacobsen, S.C. ∙ Goulding, P.P. Extended physiologic taction: design and evaluation of a proportional force feedback system J. Rehabil. Res. Dev. 1989; 26:53-62 PubMed Google Scholar
- [58]58. Mohammed, H. ∙ Hollis, 2nd, E.R. Cortical Reorganization of Sensorimotor Systems and the Role of Intracortical Circuits After Spinal Cord Injury Neurotherapeutics. 2018; 15:588-603 Crossref Scopus (27) PubMed Google Scholar
- [59]59. Moxon, K.A. ∙ Foffani, G. Brain-machine interfaces beyond neuroprosthetics Neuron. 2015; 86:55-67 Full Text Full Text (PDF) Scopus (79) PubMed Google Scholar
- [60]60. Moxon, K.A. ∙ Oliviero, A. ∙ Aguilar, J. ... Cortical reorganization after spinal cord injury: always for good? Neuroscience. 2014; 283:78-94 Crossref Scopus (93) PubMed Google Scholar
- [61]61. Obhi, S.S. ∙ Hall, P. Sense of agency and intentional binding in joint action Exp. Brain Res. 2011; 211:655-662 Crossref Scopus (102) PubMed Google Scholar
- [62]62. Ojala, M. ∙ Garriga, G. Permutation tests for studying classifier performance J. Mach. Learn. Res. 2010; 11:1833-1863 Google Scholar
- [63]63. Orsborn, A.L. ∙ Carmena, J.M. Creating new functional circuits for action via brain-machine interfaces Front. Comput. Neurosci. 2013; 7:157 Crossref Scopus (33) PubMed Google Scholar
- [65]65. Pehlivan, A. ∙ Sergi, F. ∙ Erwin, A. ... Design and validation of the RiceWrist-S exoskeleton for robotic rehabilitation after incomplete spinal cord injury Rehabilitation Robotics and Human-Robot Interaction. 2014; 32:1415-1431 Google Scholar
- [67]67. Quiroga, R.Q. ∙ Nadasdy, Z. ∙ Ben-Shaul, Y. Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering Neural Comput. 2004; 16:1661-1687 Crossref Scopus (1519) PubMed Google Scholar
- [68]68. Roux, F.E. ∙ Djidjeli, I. ∙ Durand, J.B. Functional architecture of the somatosensory homunculus detected by electrostimulation J. Physiol. 2018; 596:941-956 Crossref Scopus (87) PubMed Google Scholar
- [69]69. Rubino, D. ∙ Robbins, K.A. ∙ Hatsopoulos, N.G. Propagating waves mediate information transfer in the motor cortex Nat. Neurosci. 2006; 9:1549-1557 Crossref Scopus (332) PubMed Google Scholar
- [70]70. Sabbah, P. ∙ de, S.S. ∙ Leveque, C. ... Sensorimotor cortical activity in patients with complete spinal cord injury: a functional magnetic resonance imaging study J. Neurotrauma. 2002; 19:53-60 Crossref Scopus (113) PubMed Google Scholar
- [72]72. Schroeder, K.E. ∙ Irwin, Z.T. ∙ Bullard, A.J. ... Robust tactile sensory responses in finger area of primate motor cortex relevant to prosthetic control J. Neural Eng. 2017; 14:046016 Crossref Scopus (9) PubMed Google Scholar
- [73]73. Schwemmer, M.A. ∙ Skomrock, N.D. ∙ Sederberg, P.B. ... Meeting brain-computer interface user performance expectations using a deep neural network decoding framework Nat. Med. 2018; 24:1669-1676 Crossref Scopus (101) PubMed Google Scholar
- [74]74. Shaikhouni, A. ∙ Donoghue, J.P. ∙ Hochberg, L.R. Somatosensory responses in a human motor cortex J. Neurophysiol. 2013; 109:2192-2204 Crossref Scopus (21) PubMed Google Scholar
- [75]75. Sharma, G. ∙ Friedenberg, D.A. ∙ Annetta, N. ... Using an Artificial Neural Bypass to Restore Cortical Control of Rhythmic Movements in a Human with Quadriplegia Sci. Rep. 2016; 6:33807 Crossref Scopus (41) PubMed Google Scholar
- [76]76. Sherwood, A.M. ∙ Dimitrijevic, M.R. ∙ McKay, W.B. Evidence of subclinical brain influence in clinically complete spinal cord injury: discomplete SCI J. Neurol. Sci. 1992; 110:90-98
Cited by
Sorted by citations
Fifer, M. S., McMullen, D. P., Osborn, L. E., Thomas, T. M., Christie, B., Nickl, R. W., Candrea, D. N., Pohlmeyer, E. A., Thompson, M. C., Anaya, M. A., et al. (2022) · Neurology · doi:10.1212/wnl.0000000000013173 · Cited by 103 · see citing works
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25 · see citing works
Berger, S., & Rossi, F. (2023) · Communications of the ACM · doi:10.1145/3529088 · Cited by 21 · see citing works
- Authors
- Ganzer, P. D., Colachis, S. C., Schwemmer, M. A., Friedenberg, D. A., Dunlap, C. F., Swiftney, C. E., Jacobowitz, A. F., Weber, D. J., Bockbrader, M. A., & Sharma, G.
- Affiliations
- Battelle (US)
- The Ohio State University (US)
- Corresponding author
- Ganzer, Patrick D.
- Venue
- Cell
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 181
- Issue
- 4
- Pages
- 763-773.e12
- ISSN
- 0092-8674 (ISSN-L)
- OpenAlex
- W3018645360
- Cited by
- 156
- References
- 12
- Citations by year
- 2026: 10 · 2025: 22 · 2024: 14 · 2023: 28 · 2022: 23 · 2021: 50 · 2020: 9
- FWCI
- 14.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Cell (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Battelle
- Ohio State University (WO 2016/196797)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- spinal cord injury, brain-computer interface, touch, primary motor cortex
- MeSH terms
- Adult, Hand, Humans, Male, Motor Cortex, Movement, Spinal Cord Injuries, Touch, Hand Strength, Touch Perception, Feedback, Sensory, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review