Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Noninvasive measurement of myocardial blood flow in absolute terms (i.e., milliliters per gram per min) has been difficult to accomplish despite the intrinsically quantitative power of positron emission tomography because of the nonphysiologic nature of tracers that have been employed conventionally as well as the limited spatial resolution of currently available instruments. It was previously demonstrated that myocardial blood flow in animals can be quantitated accurately with the diffusible tracer oxygen-15-labeled water (H2(15)O) when the arterial input function and myocardial radiotracer concentration were measured directly. To extend the approach for completely noninvasive measurement of blood flow, a parameter estimation procedure was developed whereby effects of limited tomographic spatial resolution and cardiac motion were compensated for within the operational flow model. In validation studies in 18 dogs, myocardial blood flow measured with positron emission tomography after intravenously administered H2(15)O correlated closely with flow measured with concomitantly administered radiolabeled microspheres over the range of 0.29 to 5.04 ml/g per min (r = 0.95). Although regional ischemia was clearly identifiable tomographically, absolute flow could not be determined accurately in ischemic regions in four dogs because of poor count statistics related to wall thinning. Subsequently, myocardial blood flow was measured in 11 normal human subjects. Flow was homogeneous throughout the myocardium, averaged 0.90 +/- 0.22 ml/g per min at rest and increased to 3.55 +/- 1.15 ml/g per min after intravenous administration of dipyridamole. Therefore, positron emission tomography with H2 15O and the approach developed permits noninvasive measurement of myocardial blood flow in absolute terms in humans and should facilitate objective assessment of interventions designed to enhance nutritive perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
THE THEORY AND APPLICATIONS OF THE EXCHANGE OF INERT GAS AT THE LUNGS AND TISSUES
KETY, S. S. (1951) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)07246-1 · Cited by 1,663
Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143
Wilson, R. F., Laughlin, D. E., Ackell, P. H., Chilian, W. M., Holida, M. D., Hartley, C. J., Armstrong, M. L., Marcus, M. L., & White, C. W. (1985) · Circulation · doi:10.1161/01.cir.72.1.82 · Cited by 509
Quantification of regional myocardial blood flow in vivo with H215O.
Bergmann, S. R., Fox, K. A., Rand, A. L., McElvany, K. D., Welch, M. J., Markham, J., & Sobel, B. E. (1984) · Circulation · doi:10.1161/01.cir.70.4.724 · Cited by 369
Self-citationIida, H., Kanno, I., Takahashi, A., Miura, S., Murakami, M., Takahashi, K., Ono, Y., Shishido, F., Inugami, A., & Tomura, N. (1988) · Circulation · doi:10.1161/01.cir.78.1.104 · Cited by 340
Clot-Selective Coronary Thrombolysis with Tissue-Type Plasminogen Activator
Bergmann, S. R., Fox, K. A. A., Ter-Pogossian, M. M., Sobel, B. E., & Collen, D. (1983) · Science · doi:10.1126/science.6602378 · Cited by 237
Self-citationBrown, B. G., Josephson, M. A., Petersen, R. B., Pierce, C. D., Wong, M., Hecht, H. S., Bolson, E., & Dodge, H. T. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90323-4 · Cited by 227
Bergmann, S. R., Lerch, R. A., Fox, K. A. A., Ludbrook, P. A., Welch, M. J., Ter-Pogossian, M. M., & Sobel, B. E. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90338-2 · Cited by 192
Self-citationPETT VI: a positron emission tomograph utilizing cesium fluoride scintillation detectors.
Ter‐Pogossian, M. M., Ficke, D. C., Hood, J. T., Yamamoto, M., & Mullani, N. A. (1982) · PubMed · Cited by 147
PETT VI: A Positron Emission Tomograph Utilizing Cesium Fluoride Scintillation Detectors
Ter-Pogossian, M. M., Ficke, D. C., Hood, J. T., Yamamoto, M., & Mullani, N. A. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198202000-00021 · Cited by 132
Bergmann, S. R., Hack, S. N., Tewson, T. J., Welch, M. J., & Sobel, B. E. (1980) · Circulation · doi:10.1161/01.cir.61.1.34 · Cited by 121
Self-citationSuper PETT I: A Positron Emission Tomograph Utilizing Photon Time-of-Flight Information
Ter‐Pogossian, M. M., Ficke, D. C., Yamamoto, M., & Hood, J. T. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307570 · Cited by 121
Influence of Cardiac and Respiratory Motion on Tomographic Reconstructions of the Heart
Ter‐Pogossian, M. M., Bergmann, S. R., & Sobel, B. E. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198212000-00016 · Cited by 99
Self-citationPositron emission tomography of the heart
Bergmann, S. R., Fox, K. A. A., Geltman, E. M., & Sobel, B. E. (1985) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(85)90014-3 · Cited by 92
Self-citationFoster, D. O., & Frydman, M. L. (1978) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y78-014 · Cited by 69
Daley, P. J., Mahn, T. H., Zielonka, J. S., Krubsack, A. J., AKHTAR, R., & Bamrah, V. S. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90006-3 · Cited by 27
Cited by
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Relation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
Peterson, L. R., Herrero, P., Schechtman, K. B., Racette, S. B., Waggoner, A. D., Kisrieva-Ware, Z., Dence, C., Klein, S., Marsala, J., Meyer, T., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127959.28627.f8 · Cited by 656
Self-citationDilsizian, V., Bacharach, S. L., Beanlands, R. S., Bergmann, S. R., Delbeke, D., Dorbala, S., Gropler, R. J., Knuuti, J., Schelbert, H. R., & Travin, M. I. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-016-0522-3 · Cited by 612
Self-citationAl-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Metadata
- Authors
- Bergmann, S. R., Herrero, P., Markham, J., Weinheimer, C. J., & Walsh, M. N.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1989-09
- Volume
- 14
- Issue
- 3
- Pages
- 639-652
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2012733542
- Cited by
- 439
- References
- 17
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.