Duplex ultrasound criteria for diagnosis of splanchnic artery stenosis or occlusion
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Duplex ultrasound measurement of postprandial intestinal blood flow: Effect of meal composition
Moneta, G. L., Taylor, D. C., Helton, W. S., Mulholland, M. W., & Strandness, D. E. (1988) · Gastroenterology · doi:10.1016/0016-5085(88)90364-2 · Cited by 277
Self-citationRenal duplex sonography: Evaluation of clinical utility
Hansen, K. J., Tribble, R. W., Reavis, S. W., Canzanello, V. J., Craven, T. E., Plonk, G. W., & Dean, R. H. (1990) · Journal of Vascular Surgery · doi:10.1016/0741-5214(90)90141-v · Cited by 256
Duplex ultrasound scanning in the diagnosis of renal artery stenosis: A prospective evaluation
Taylor, D. C., Kettler, M. D., Moneta, G. L., Kohler, T. R., Kazmers, A., Beach, K. W., & Strandness, D. E. (1988) · Journal of Vascular Surgery · doi:10.1016/0741-5214(88)90156-5 · Cited by 248
Self-citationNoninvasive diagnosis of renal artery stenosis by ultrasonic duplex scanning
Kohler, T. R., Zierler, R. E., Martin, R. L., Nicholls, S. C., Bergelin, R. O., Kazmers, A., Beach, K. W., & Strandness, D. E. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90379-4 · Cited by 234
Ultrasonic duplex scanning for disease of the carotid artery.
Fell, G., Phillips, D. J., Chikos, P. M., Harley, J. D., Thiele, B. L., & Strandness, D. E. (1981) · Circulation · doi:10.1161/01.cir.64.6.1191 · Cited by 220
Berland, L. L., Koslin, D. B., Routh, W. D., & Keller, F. S. (1990) · Radiology · doi:10.1148/radiology.174.2.2404314 · Cited by 168
Measurement of mesenteric blood flow by duplex scanning
Jäger, K., Bollinger, A., Valli, C., & Ammann, R. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90109-6 · Cited by 166
Use of hemodynamic parameters in the diagnosis of mesenteric insufficiency
Nicholls, S. C., Kohler, T. R., Martin, R. L., & Strandness, D. E. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90117-5 · Cited by 93
Lilly, M. P., Harward, T. R. S., Flinn, W. R., Blackburn, D. R., Astleford, P., & Yao, J. S. T. (1989) · Journal of Vascular Surgery · doi:10.1067/mva.1989.vs0090018 · Cited by 68
Mesenteric flow velocity variations as a function of angle of insonation
Rizzo, R. J., Sandager, G. P., Astleford, P. M., Payne, K., Peterson-Kennedy, L., Flinn, W. R., & Yao, J. S. T. (1990) · Journal of Vascular Surgery · doi:10.1016/0741-5214(90)90215-v · Cited by 60
Cited by
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.009 · Cited by 1,021
AGA technical review on intestinal ischemia
Brandt, L. J., & Boley, S. J. (2000) · Gastroenterology · doi:10.1016/s0016-5085(00)70183-1 · Cited by 606
Clair, D. G., & Beach, J. M. (2016) · New England Journal of Medicine · doi:10.1056/nejmra1503884 · Cited by 589
Non-occlusive mesenteric ischemia: etiology, diagnosis, and interventional therapy
Trompeter, M., Brazda, T., Remy, C. T., Vestring, T., & Reimer, P. (2002) · European Radiology · doi:10.1007/s00330-001-1220-2 · Cited by 378
Mesenteric duplex scanning: A blinded prospective study
Moneta, G. L., Lee, R. W., Yeager, R. A., Taylor, L. M., & Porter, J. M. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90011-a · Cited by 283
Self-citationMesenteric ischaemia: A multidisciplinary approach
Bradbury, A. W., Brittenden, J., McBride, K., & Ruckley, C. V. (1995) · Journal of British Surgery · doi:10.1002/bjs.1800821105 · Cited by 239
(2006) · Circulation · doi:10.1161/circulationaha.106.173994 · Cited by 201
ACR appropriateness criteria® imaging of mesenteric ischemia
Oliva, I. B., Davarpanah, A. H., Rybicki, F. J., Desjardins, B., Flamm, S. D., Francois, C. J., Gerhard-Herman, M. D., Kalva, S. P., Ashraf Mansour, M., Mohler, E. R., et al. (2013) · Abdominal Imaging · doi:10.1007/s00261-012-9975-2 · Cited by 200
Meaney, J. F. M., Prince, M. R., Nostrant, T. T., & Stanley, J. C. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070126 · Cited by 193
Mesenteric angioplasty in the treatment of chronic intestinal ischemia
Allen, R. C., Martin, G. H., Rees, C. R., Rivera, F. J., Talkington, C. M., Garrett, W. V., Smith, B. L., Pearl, G. J., Diamond, N. G., Lee, S. P., et al. (1996) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(96)70197-0 · Cited by 174
Kim, E. S., Sharma, A. M., Scissons, R., Dawson, D., Eberhardt, R. T., Gerhard-Herman, M., Hughes, J. P., Knight, S., Marie Kupinski, A., Mahe, G., et al. (2020) · Vascular Medicine · doi:10.1177/1358863x20937665 · Cited by 169
Mesenteric artery bypass: Objective patency determination
McMillan, W. D., McCarthy, W. J., Bresticker, M. R., Pearce, W. H., Schneider, J. R., Golan, J. F., & Yao, J. S. T. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(05)80004-7 · Cited by 163
Mesenteric and celiac duplex scanning: a validation study
Zwolak, R. M., Fillinger, M. F., Walsh, D. B., LaBombard, F. A., Musson, A., Darling, C. E., & Cronenwett, J. L. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)60010-0 · Cited by 162
Roobottom, C. A., & Dubbins, P. A. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.5.8273642 · Cited by 161
Thrombolytic therapy for acute superior mesenteric artery occlusion
Schoots, I. G., Levi, M. M., Reekers, J. A., Lameris, J. S., & van Gulik, T. M. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000141719.24321.0b · Cited by 152
Chronic mesenteric ischemia: Clinical practice guidelines from the Society for Vascular Surgery
Huber, T. S., Björck, M., Chandra, A., Clouse, W. D., Dalsing, M. C., Oderich, G. S., Smeds, M. R., & Murad, M. H. (2021) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2020.10.029 · Cited by 152
INTESTINAL (MESENTERIC) VASCULOPATHY I
Cappell, M. S. (1998) · Gastroenterology Clinics of North America · doi:10.1016/s0889-8553(05)70033-9 · Cited by 127
ISCHEMIC BOWEL DISEASE IN THE ELDERLY
Greenwald, D. A., Brandt, L. J., & Reinus, J. F. (2001) · Gastroenterology Clinics of North America · doi:10.1016/s0889-8553(05)70190-4 · Cited by 108
Duplex velocity criteria for native celiac/superior mesenteric artery stenosis vs in-stent stenosis
AbuRahma, A. F., Mousa, A. Y., Stone, P. A., Hass, S. M., Dean, L. S., & Keiffer, T. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.10.086 · Cited by 55
van Petersen, A. S., Meerwaldt, R., Kolkman, J. J., Huisman, A. B., van der Palen, J., van Bockel, J. H., Zeebregts, C. J., & Geelkerken, R. H. (2013) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2012.11.120 · Cited by 37
Duplex ultrasound criteria for in-stent restenosis of mesenteric arteries
Soult, M. C., Wuamett, J. C., Ahanchi, S. S., Stout, C. L., Larion, S., & Panneton, J. M. (2016) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2016.06.103 · Cited by 28
Chronic Mesenteric Ischemia: Diagnosis and Treatment
Char, D., & Hines, G. (2001) · Heart Disease · doi:10.1097/00132580-200107000-00005 · Cited by 22
Barnes, J. A., Columbo, J. A., Ponukumati, A. S., Zwolak, R. M., Olive, F. T., Goodney, P. P., Powell, R. J., & Zacharias, N. (2020) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2020.04.064 · Cited by 12
The radiologist’s guide to duplex ultrasound assessment of chronic mesenteric ischemia
Revzin, M. V., Pellerito, J. S., Nezami, N., & Moshiri, M. (2020) · Abdominal Radiology · doi:10.1007/s00261-019-02165-2 · Cited by 10
“The mesenteric artery is considered to have greater than 70% stenosis if PSV is greater than 275 cm/s for the SMA, and 200 cm/s for both the celiac and inferior mesenteric arteries [25, 37].”
BackgroundEarly Identification of Chronic Mesenteric Ischemia with Endoscopic Duplex Ultrasound
Safi, N., Ånonsen, K. V., Berge, S. T., Medhus, A. W., Sundhagen, J. O., Hisdal, J., & Kazmi, S. S. H. (2022) · Vascular Health and Risk Management · doi:10.2147/vhrm.s358570 · Cited by 7
Kazmi, S. S. H., Safi, N., Berge, S. T., Kazmi, M., Sundhagen, J. O., Julien, K., Thorsby, P. M., Ånonsen, K. V., Medhus, A. W., & Hisdal, J. (2022) · Vascular Health and Risk Management · doi:10.2147/vhrm.s365625 · Cited by 7
Metadata
- Authors
- Moneta, G. L., Yeager, R. A., Dalman, R., Antonovic, R., Hall, L. D., & Porter, J. M.
- Venue
- Journal of Vascular Surgery
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 14
- Issue
- 4
- Pages
- 511-520
- ISSN
- 0741-5214 (ISSN-L)
- OpenAlex
- W2073024627
- Cited by
- 235
- References
- 13
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.