Reduction in experimental pericardial adhesions using a hyaluronic acid bioabsorbable membrane
The DOI matches its Crossref record.
Abstract
Various materials have been suggested for pericardial closure following cardiac surgery to limit postoperative adhesion formation. Unfortunately, these devices have caused difficulties with infection, calcification, and epicardial scar formation. A bioabsorbable membrane with a short in-vivo persistence time, acting as a barrier to adhesion formation until mesothelial healing occurs, might obviate many of these problems. We examined the efficacy of a bioabsorbable membrane containing hyaluronic acid in the prevention of experimental pericardial adhesions; hyaluronic acid solutions have been shown experimentally to reduce adhesions following abdominal, orthopedic and cardiac surgery. Eleven dogs underwent sternotomy and pericardiotomy followed by 2-h protocol of desiccation and abrasion of pericardial and epicardial surfaces. In five dogs, the epicardial surfaces were covered with the test material, followed by pericardial and sternotomy closure. Six dogs served as controls. All animals underwent resternotomy 8 weeks after surgery; intrapericardial adhesions were graded on a severity scale (0-4). The test animals (mean adhesion score 1.4 +/- 0.5) had either no adhesions or filmy, avascular adhesions easily taken down with blunt dissection. In contrast, dense adhesions were found in the control animals (mean score 3.2 +/- 0.4), frequently obscuring tissue planes and epicardial anatomy. Use of the bioabsorbable membrane significantly reduced adhesion formation (test vs control, P < 0.001, Mann-Whitney test). We conclude that a hyaluronic acid membrane reduces postoperative pericardial adhesions in this canine model, and that the use of a bioabsorbable barrier in the prevention of pericardial adhesions warrants further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diamond, M. P., & The Seprafilm Adhesion Study Group (1996) · Fertility and Sterility · doi:10.1016/s0015-0282(16)58716-0 · Cited by 457
Prevention of Post-Operative Adhesions: A Comprehensive Review of Present and Emerging Strategies
Fatehi Hassanabad, A., Zarzycki, A. N., Jeon, K., Dundas, J. A., Vasanthan, V., Deniset, J. F., & Fedak, P. W. M. (2021) · Biomolecules · doi:10.3390/biom11071027 · Cited by 178
Seprafilm® adhesion barrier: (1) a review of preclinical, animal, and human investigational studies
Diamond, M. P., Burns, E. L., Accomando, B., Mian, S., & Holmdahl, L. (2012) · Gynecological Surgery · doi:10.1007/s10397-012-0741-9 · Cited by 107
“Additionally, Seprafilm has been reported to be safe and beneficial when used in conjunction with cardiac surgery [49–51], tendon surgery [52], joint surgery [53], spinal surgery [54–56], strabismus surgery [57], and tympanic membrane surgery [58].”
BackgroundOsada, H., Tanaka, H., Fujii, T., Tsunoda, I., Yoshida, T., & Satoh, K. (1999) · Journal of International Medical Research · doi:10.1177/030006059902700505 · Cited by 29
Evaluation of the effectiveness of alginate-based hydrogels in preventing peritoneal adhesions
Meng, Z., Wang, H., Liu, Y., Yang, M., Zeng, H., & Han, Q. (2023) · Regenerative Biomaterials · doi:10.1093/rb/rbad017 · Cited by 15
Use of Fibrin Adhesive to Reduce Post-Surgical Adhesion Reformation in Rabbits
Osada, H., Minai, M., Yoshida, T., & Satoh, K. (1999) · Journal of International Medical Research · doi:10.1177/030006059902700504 · Cited by 9
Metadata
- Authors
- MITCHELL, J., LEE, R., NEYA, K., & VLAHAKES, G.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 1994
- Volume
- 8
- Issue
- 3
- Pages
- 149-152
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W1977241855
- Cited by
- 45
- References
- 0
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.