Time-resolved detection of lanthanide luminescence for ultrasensitive bioanalytical assays
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horrocks, W. D., & Sudnick, D. R. (1979) · Journal of the American Chemical Society · doi:10.1021/ja00496a010 · Cited by 1,413
Lanthanide ion luminescence probes of the structure of biological macromolecules
Horrocks, W. D., & Sudnick, D. R. (1981) · Accounts of Chemical Research · doi:10.1021/ar00072a004 · Cited by 1,069
Practice and Theory of Enzyme Immunoassays
(1985) · Laboratory Techniques in Biochemistry and Molecular Biology · doi:10.1016/s0075-7535(08)x7008-1 · Cited by 883
Europium as a label in time-resolved immunofluorometric assays
Hemmilä, I., Dakubu, S., Mukkala, V.-M., Siitari, H., & Lövgren, T. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90095-2 · Cited by 833
The biotin-(strept)avidin system: principles and applications in biotechnology
Diamandis, E. P., & Christopoulos, T. K. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.5.625 · Cited by 747
Self-citationA Decade of Development in Immunoassay Methodology
Gosling, J. P. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.8.1408 · Cited by 457
Time-Resolved Fluorescence of Lanthanide Probes and Applications in Biotechnology
Soini, E. J., Lövgren, T. N.-E., & Reimer, C. B. (1987) · C R C Critical Reviews in Analytical Chemistry · doi:10.1080/10408348708542802 · Cited by 417
Rare earth cryptates and homogeneous fluoroimmunoassays with human sera
Mathis, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.9.1953 · Cited by 392
Time-resolved fluorometer for lanthanide chelates--a new generation of nonisotopic immunoassays.
Soini, E., & Kojola, H. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.65 · Cited by 386
Immunoassays with time-resolved fluorescence spectroscopy: Principles and applications
Diamandis, E. P. (1988) · Clinical Biochemistry · doi:10.1016/0009-9120(88)90001-x · Cited by 307
Self-citation
Cited by
Bile Acids: Natural Ligands for an Orphan Nuclear Receptor
Parks, D. J., Blanchard, S. G., Bledsoe, R. K., Chandra, G., Consler, T. G., Kliewer, S. A., Stimmel, J. B., Willson, T. M., Zavacki, A. M., Moore, D. D., et al. (1999) · Science · doi:10.1126/science.284.5418.1365 · Cited by 2,274
Sapsford, K. E., Algar, W. R., Berti, L., Gemmill, K. B., Casey, B. J., Oh, E., Stewart, M. H., & Medintz, I. L. (2013) · Chemical Reviews · doi:10.1021/cr300143v · Cited by 1,423
Bioinorganic Photochemistry: Frontiers and Mechanisms
Szaciłowski, K., Macyk, W., Drzewiecka-Matuszek, A., Brindell, M., & Stochel, G. (2005) · Chemical Reviews · doi:10.1021/cr030707e · Cited by 725
Algar, W. R., Prasuhn, D. E., Stewart, M. H., Jennings, T. L., Blanco-Canosa, J. B., Dawson, P. E., & Medintz, I. L. (2011) · Bioconjugate Chemistry · doi:10.1021/bc200065z · Cited by 502
Applications of lanthanide luminescence spectroscopy to solution studies of coordination chemistry
Choppin, G. R., & Peterman, D. R. (1998) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00125-8 · Cited by 389
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
“Unfortunately, the known chelates are not stable or are poorly fluorescent in biological media (14-16).”
Nanoparticle labels in immunosensing using optical detection methods
Seydack, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.003 · Cited by 314
Recent advances in utilization of transition metal complexes and lanthanides as diagnostic tools
Yam, V. W.-W., & Lo, K. K.-W. (1999) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00262-8 · Cited by 268
Szöllosi, J., Damjanovich, S., & Mátyus, L. (1998) · Cytometry · doi:10.1002/(sici)1097-0320(19980815)34:4<159::aid-cyto1>3.3.co;2-9 · Cited by 214
Metallogels: Availability, Applicability, and Advanceability
Wu, H., Zheng, J., Kjøniksen, A., Wang, W., Zhang, Y., & Ma, J. (2019) · Advanced Materials · doi:10.1002/adma.201806204 · Cited by 183
Alexander, C., Guo, Z., Glover, P. B., Faulkner, S., & Pikramenou, Z. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00615 · Cited by 182
Zhou, G. (1998) · Molecular Endocrinology · doi:10.1210/me.12.10.1594 · Cited by 172
Temporally and Spectrally Resolved Imaging Microscopy of Lanthanide Chelates
Vereb, G., Jares-Erijman, E., Selvin, P. R., & Jovin, T. M. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77930-5 · Cited by 161
Double-Lanthanide-Binding Tags: Design, Photophysical Properties, and NMR Applications
Martin, L. J., Hähnke, M. J., Nitz, M., Wöhnert, J., Silvaggi, N. R., Allen, K. N., Schwalbe, H., & Imperiali, B. (2007) · Journal of the American Chemical Society · doi:10.1021/ja070480v · Cited by 160
Metadata
- Authors
- Gudgin Dickson, E. F., Pollak, A., & Diamandis, E. P.
- Venue
- Journal of Photochemistry and Photobiology B: Biology
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 27
- Issue
- 1
- Pages
- 3-19
- ISSN
- 1011-1344 (ISSN-L)
- OpenAlex
- W2059546764
- Cited by
- 182
- References
- 40
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.