Ion formation from charged droplets: Roles of geometry, energy, and time
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The formation of ions from the charged droplets produced in the several spray ionization techniques is viewed as an activated rate process involving field-assisted desorption, in accord with the ideas first set forth by Iribame and Thomson. The novel features of the present treatment are particularly relevant to the unique ability of electrospray ionization to transform large molecules in solution to free ions in the gas phase, with extensive multiple charging. These new features stem mainly from the realization that the spacing of charges on a desorbed ion must relate to the spacing of charges on the surface of the droplet whence it came. The consequences of this "rule" can account for the existence of maxima and minima in the number of charges on the ions of a particular species as well as the nature of the distribution of ions among the intervening charge states. They also explain the dependence of charge state on the configuration in solution of the parent molecule of the desorbed ion. In addition, they provide insight into the sequence in time at which ions in the various charge states leave an evaporating droplet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Instability of Electrified Liquid Surfaces
Zeleny, J. (1917) · Physical Review · doi:10.1103/physrev.10.1 · Cited by 944
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
A new soft ionization technique for mass spectrometry of complex molecules
Blakley, C. R., Carmody, J. J., & Vestal, M. L. (1980) · Journal of the American Chemical Society · doi:10.1021/ja00538a050 · Cited by 275
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D. (1990) · Analytical Chemistry · doi:10.1021/ac00206a009 · Cited by 274
Electrified droplet fission and the Rayleigh limit
Taflin, D. C., Ward, T. L., & Davis, E. J. (1989) · Langmuir · doi:10.1021/la00086a016 · Cited by 266
Electrospray mass spectrometry of poly(ethylene glycols) with molecular weights up to five million
Nohmi, T., & Fenn, J. B. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00035a012 · Cited by 217
Self-citationDesolvation of ions and molecules in thermospray mass spectrometry
Schmelzeisen-Redeker, G., Bütfering, L., & Röllgen, F. W. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85004-9 · Cited by 163
Are the electrospray mass spectra of proteins related to their aqueous solution chemistry?
Guevremont, R., Siu, K. W. M., Blanc, J. C. Y. L., & Berman, S. S. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87005-j · Cited by 134
Cited by
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Metadata
- Authors
- Fenn, J. B.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-07-01
- Volume
- 4
- Issue
- 7
- Pages
- 524-535
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2016717705
- Cited by
- 518
- References
- 13
- FWCI
- 16.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.