Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The coupling of electrospray ionization with Fourier-transform mass spectrometry allows the analysis of large biomolecules with mass-measuring errors of less than 1 ppm. The large number of atoms incorporated in these molecules results in a low probability for the all-monoisotopic species. This produces the potential to misassign the number of heavy isotopes in a specific peak and make a mass error of ±1 Da, although the certainty of the measurement beyond the decimal place is greater than 0.1 Da. Statistical tests are used to compare the measured isotopic distribution with the distribution for a model molecule of the same average molecular mass, which allows the assignment of the monoisotopic mass, even in cases where the monoisotopic peak is absent from the spectrum. The statistical test produces error levels that are inversely proportional to the number of molecules in a distribution, which allows an estimation of the number of ions in the trapped ion cell. It has been determined, via this method that 128 charges are required to produce a signal-to-noise ratio of 3:1, which correlates well with previous experimental methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“THRASH uses a theoretical isotopomer envelope based on the average elemental composition of amino acids (averagine) [125] to compare to the experimental envelopes. A statistical score is then assigned based on the overlap of the experimental and theoretical fit.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [125]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
A general approach to calculating isotopic distributions for mass spectrometry
Yergey, J. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)85053-0 · Cited by 222
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Research works printed but not linked: 2
- 1. Teer, D.; Dole, M. J. Polym. Sci. 1975, 13, 985.
- 21. Labowski, M.; Whitehouse, C. M.; Fenn, J. B. Rapid Commun. Mass Spectrom. 1993, 7, 71.
Cited by
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
“An edge is inserted between two peaks when the difference in mass equals the difference in isotope mass of an average amino acid ('averagine”
BackgroundAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
“1985, 18, 316–322. sition (Senko et al., 1995).”
mMass 3: A Cross-Platform Software Environment for Precise Analysis of Mass Spectrometric Data
Strohalm, M., Kavan, D., Novák, P., Volný, M., & Havlíček, V. (2010) · Analytical Chemistry · doi:10.1021/ac100818g · Cited by 806
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
“Second, the most probable monoisotopic mass is determined by chi-squared fitting of the isotopic peak abundances found for a spectral cluster to that calculated for an average nucleotide or protein (“averagine”) of the observed mass [25].”
BackgroundMethodInfluentialAttomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Systematic analysis of protein turnover in primary cells
Mathieson, T., Franken, H., Kosinski, J., Kurzawa, N., Zinn, N., Sweetman, G., Poeckel, D., Ratnu, V. S., Schramm, M., Becher, I., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03106-1 · Cited by 379
Advances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Extracting Accurate Precursor Information for Tandem Mass Spectra by RawConverter
He, L., Diedrich, J., Chu, Y.-Y., & Yates, J. R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02721 · Cited by 306
Milestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
The use of mass defect in modern mass spectrometry
Sleno, L. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.2953 · Cited by 283
Schweppe, D. K., Eng, J. K., Yu, Q., Bailey, D., Rad, R., Navarrete-Perea, J., Huttlin, E. L., Erickson, B. K., Paulo, J. A., & Gygi, S. P. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00860 · Cited by 286
Pino, L. K., Just, S. C., MacCoss, M. J., & Searle, B. C. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.p119.001913 · Cited by 284
“(31) and there are regions of m/z values (“forbidden zones”)”
BackgroundOptimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics
Haas, W., Faherty, B. K., Gerber, S. A., Elias, J. E., Beausoleil, S. A., Bakalarski, C. E., Li, X., Villén, J., & Gygi, S. P. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500339-mcp200 · Cited by 261
“dta format for the acquired MS/MS spectra(2) (31).”
BackgroundEnhanced Global Post-translational Modification Discovery with MetaMorpheus
Solntsev, S. K., Shortreed, M. R., Frey, B. L., & Smith, L. M. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00873 · Cited by 262
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Boiko, D. A., Kozlov, K. S., Burykina, J. V., Ilyushenkova, V. V., & Ananikov, V. P. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c03631 · Cited by 214
Jaitly, N., Mayampurath, A., Littlefield, K., Adkins, J. N., Anderson, G. A., & Smith, R. D. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-87 · Cited by 217
“The most likely empirical composition is determined using the average mass determined in step 2 and the Averagine algorithm [17], which assumes an empirical composition that is equal to the average composition of all the peptides in a protein FASTA file.”
MethodFast Deisotoping Algorithm and Its Implementation in the MSFragger Search Engine
Teo, G. C., Polasky, D. A., Yu, F., & Nesvizhskii, A. I. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00544 · Cited by 223
Informatics and multiplexing of intact protein identification in bacteria and the archaea
Meng, F., Cargile, B. J., Miller, L. M., Forbes, A. J., Johnson, J. R., & Kelleher, N. L. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-952 · Cited by 208
“1 Da (the mass of the average amino acid, weighted for its occurrence in protein”
BackgroundIdentification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Ayoub, D., Jabs, W., Resemann, A., Evers, W., Evans, C., Main, L., Baessmann, C., Wagner-Rousset, E., Suckau, D., & Beck, A. (2013) · mAbs · doi:10.4161/mabs.25423 · Cited by 184
Li, X.-J., Yi, E. C., Kemp, C. J., Zhang, H., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500141-mcp200 · Cited by 185
“Assuming the most intense signal is produced by the monoisotopic mass ( M ) of a peptide, the software then calculates the expected peptide isotopic distribution (34, 35) and assesses how well the distribution fits neighboring MS signals.”
BackgroundMaxQuant Software for Ion Mobility Enhanced Shotgun Proteomics
Prianichnikov, N., Koch, H., Koch, S., Lubeck, M., Heilig, R., Brehmer, S., Fischer, R., & Cox, J. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001720 · Cited by 189
Fornelli, L., Ayoub, D., Aizikov, K., Beck, A., & Tsybin, Y. O. (2014) · Analytical Chemistry · doi:10.1021/ac4036857 · Cited by 177
Beck, S., Michalski, A., Raether, O., Lubeck, M., Kaspar, S., Goedecke, N., Baessmann, C., Hornburg, D., Meier, F., Paron, I., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.047407 · Cited by 175
“Data was analyzed using the SNAP algorithm to fit the theoretical pattern (36, 37).”
MethodDeconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Matching Cross-linked Peptide Spectra: Only as Good as the Worse Identification
Trnka, M. J., Baker, P. R., Robinson, P. J. J., Burlingame, A. L., & Chalkley, R. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034009 · Cited by 176
“a mass defect derived from averagine (26)) and regards pep-”
BackgroundShaw-Reid, C. A., Kelleher, N. L., Losey, H. C., Gehring, A. M., Berg, C., & Walsh, C. T. (1999) · Chemistry & Biology · doi:10.1016/s1074-5521(99)80050-7 · Cited by 164
An automated pipeline for high-throughput label-free quantitative proteomics
Weisser, H., Nahnsen, S., Grossmann, J., Nilse, L., Quandt, A., Brauer, H., Sturm, M., Kenar, E., Kohlbacher, O., Aebersold, R., et al. (2013) · Journal of Proteome Research · doi:10.1021/pr300992u · Cited by 160
Informed-Proteomics: open-source software package for top-down proteomics
Park, J., Piehowski, P. D., Wilkins, C., Zhou, M., Mendoza, J., Fujimoto, G. M., Gibbons, B. C., Shaw, J. B., Shen, Y., Shukla, A. K., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4388 · Cited by 148
“For each average mass, a theoretical isotopomer envelope is generated from Averagine model 34 .”
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Fornelli, L., Srzentić, K., Huguet, R., Mullen, C., Sharma, S., Zabrouskov, V., Fellers, R. T., Durbin, K. R., Compton, P. D., & Kelleher, N. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00984 · Cited by 150
TIGER: the universal biosensor
Hofstadler, S. A., Sampath, R., Blyn, L. B., Eshoo, M. W., Hall, T. A., Jiang, Y., Drader, J. J., Hannis, J. C., Sannes, K. A., Cummins, L. L., et al. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.09.014 · Cited by 149
Shi, S. D.-H., Hendrickson, C. L., & Marshall, A. G. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.20.11532 · Cited by 149
Mayampurath, A. M., Jaitly, N., Purvine, S. O., Monroe, M. E., Auberry, K. J., Adkins, J. N., & Smith, R. D. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn063 · Cited by 142
“This step is accomplished by first calculating the charge using autocorrelationbased peak fitting methods (Senko et al., 1995), following which the monoisotopic mass is calculated by overlapping a calculated theoretical profile (Senko et al., 1995b; Rockwood et al., 1995) with the observed profile.”
MethodComputational Methods for Understanding Mass Spectrometry–Based Shotgun Proteomics Data
Sinitcyn, P., Rudolph, J. D., & Cox, J. (2018) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-080917-013516 · Cited by 143
Boundaries of Mass Resolution in Native Mass Spectrometry
Lössl, P., Snijder, J., & Heck, A. J. R. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0874-3 · Cited by 136
“This is also illustrated in Figure 3, where we simulate the 26+ charge state of a 150 kDa “averagine” protein (1350 averagine residues [61]) in its unmodified, ammonium-bound, and sodium-bound form.”
MASH Suite Pro: A Comprehensive Software Tool for Top-Down Proteomics
Cai, W., Guner, H., Gregorich, Z. R., Chen, A. J., Ayaz-Guner, S., Peng, Y., Valeja, S. G., Liu, X., & Ge, Y. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o115.054387 · Cited by 132
“envelopes generated using averagine (48).”
MethodLermyte, F., Tsybin, Y. O., O’Connor, P. B., & Loo, J. A. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02201-x · Cited by 132
“As depicted in Figure 3, however, the monoisotopic peak is usually too low in intensity to be observed, potentially complicating data analysis [71].”
BackgroundAccurate mass measurements by Fourier transform mass spectrometry
Zhang, L., Rempel, D. L., Pramanik, B. N., & Gross, M. L. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.20013 · Cited by 137
Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy
Kelleher, N. L., Senko, M. W., Siegel, M. M., & McLafferty, F. W. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00060-3 · Cited by 122
Self-citationImproved Monoisotopic Mass Estimation for Deeper Proteome Coverage
Rad, R., Li, J., Mintseris, J., O’Connell, J., Gygi, S. P., & Schweppe, D. K. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00563 · Cited by 121
MaxQuant.Live Enables Global Targeting of More Than 25,000 Peptides
Wichmann, C., Meier, F., Virreira Winter, S., Brunner, A.-D., Cox, J., & Mann, M. (2019) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.001131 · Cited by 118
193 nm photodissociation of larger multiply-charged biomolecules
Guan, Z., Kelleher, N. L., O’Connor, P. B., Aaserud, D. J., Little, D. P., & McLafferty, F. W. (1996) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04399-6 · Cited by 113
Current challenges in software solutions for mass spectrometry-based quantitative proteomics
Cappadona, S., Baker, P. R., Cutillas, P. R., Heck, A. J. R., & van Breukelen, B. (2012) · Amino Acids · doi:10.1007/s00726-012-1289-8 · Cited by 133
“In these cases, where the peptide sequence is unknown, the averagine model can be used to estimate peptide isotopic distributions, based on the assumption that the dependence of mass is a good approximation to the dependence on sequence (Senko et al. 1995).”
MethodE LECTROSPRAY I ONIZATION F OURIER T RANSFORM I ON C YCLOTRON R ESONANCE M ASS S PECTROMETRY
Hendrickson, C. L., & Emmett, M. R. (1999) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.50.1.517 · Cited by 110
Yuan, Z.-F., Lin, S., Molden, R. C., Cao, X.-J., Bhanu, N. V., Wang, X., Sidoli, S., Liu, S., & Garcia, B. A. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.046011 · Cited by 109
“The theoretical isotopic pattern of the precursor can be calculated using its mass and the “averagine” model (28).”
MethodIdentification of intrinsic order and disorder in the DNA repair protein XPA
Iakoucheva, L. M., Kimzey, A. L., Masselon, C. D., Bruce, J. E., Garner, E. C., Brown, C. J., Dunker, A. K., Smith, R. D., & Ackerman, E. J. (2001) · Protein Science · doi:10.1110/ps.29401 · Cited by 108
“Measured masses were derived from the detected isotopic distribution by using the “averagine” (Senko et al. 1995) hypothetical average protein and were compared with the monoisotopic (MW<15,000) or most abundant isotope (MW 15,000) calculated masses of the predicted tryptic fragments of xXPA.”
MethodAutomated Label-free Quantification of Metabolites from Liquid Chromatography–Mass Spectrometry Data
Kenar, E., Franken, H., Forcisi, S., Wörmann, K., Häring, H., Lehmann, R., Schmitt‐Kopplin, P., Zell, A., & Kohlbacher, O. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031278 · Cited by 115
“In proteomics, a popular choice for many feature-detection algorithms is to match the shape of peptide isotope patterns against an “averagine” model (19, 20).”
MethodAccurate Mass Measurements in Proteomics
Liu, T., Belov, M. E., Jaitly, N., Qian, W.-J., & Smith, R. D. (2007) · Chemical Reviews · doi:10.1021/cr068288j · Cited by 104
Data processing in Fourier transform ion cyclotron resonance mass spectrometry
Qi, Y., & O’Connor, P. B. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21414 · Cited by 114
Rapid Identification of Emerging Pathogens: Coronavirus
Sampath, R., Hofstadler, S. A., Blyn, L. B., Eshoo, M. W., Hall, T. A., Massire, C., Levene, H., Hannis, J. C., Harrell, P. M., Neuman, B. W., et al. (2005) · Emerging infectious diseases · doi:10.3201/eid1103.040629 · Cited by 100
“The ICR-2LS software package (23) was used to deconvolute the mass spectra and calculate the mass of the monoisotopic species using an “averagine” fitting routine (24) modified for DNA (Drader et al.”
MethodKelleher, N. L., Taylor, S. V., Grannis, D., Kinsland, C., Chiu, H., Begley, T. P., & Mclafferty, F. W. (1998) · Protein Science · doi:10.1002/pro.5560070815 · Cited by 100
Top-down Proteomics: Technology Advancements and Applications to Heart Diseases
Cai, W., Tucholski, T. M., Gregorich, Z. R., & Ge, Y. (2016) · Expert Review of Proteomics · doi:10.1080/14789450.2016.1209414 · Cited by 99
“THRASH compares the experimental isotopomer envelope with a theoretical envelope generated based on the averagine [83], computes a figure of merit value for each envelope, and reports those score higher than a user-defined fit score.”
BackgroundProtein-based stable isotope probing
Jehmlich, N., Schmidt, F., Taubert, M., Seifert, J., Bastida, F., von Bergen�, M., Richnow, H. H., & Vogt, C. (2010) · Nature Protocols · doi:10.1038/nprot.2010.166 · Cited by 117
Malyarenko, D. I., Cooke, W. E., Adam, B.-L., Malik, G., Chen, H., Tracy, E. R., Trosset, M. W., Sasinowski, M., Semmes, O. J., & Manos, D. M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.037283 · Cited by 99
“The low mass edge of the mass peaks is sharper because of the absence of adducts and the natural skew of isotopic distributions ( 19 ), and we find that this choice of filters best uses the inherent instrument resolution.”
BackgroundMethodKarabacak, N. M., Li, L., Tiwari, A., Hayward, L. J., Hong, P., Easterling, M. L., & Agar, J. N. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800099-mcp200 · Cited by 96
“SNAP uses a given mass, charge, and mean molecular constitution (in our case averagine (52)) to calculate isotopic distribution to obtain a nonlinear fit to the data in a similar fashion to the THRASH (thorough high resolution analysis of spectra by Horn) algorithm introduced by Horn et al.”
MethodAnalysis of nucleic acids by FTICR MS
Hofstadler, S. A., Sannes, K. A., & Hannis, J. C. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.20016 · Cited by 94
Vékey, K. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140304 · Cited by 93
An atlas of protein turnover rates in mouse tissues
Rolfs, Z., Frey, B. L., Shi, X., Kawai, Y., Smith, L. M., & Welham, N. V. (2021) · Nature Communications · doi:10.1038/s41467-021-26842-3 · Cited by 101
The isotopic distribution conundrum
Valkenborg, D., Mertens, I., Lemière, F., Witters, E., & Burzykowski, T. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20339 · Cited by 105
Edmondson, R. D., & Russell, D. H. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(96)00027-x · Cited by 90
Metz, T., Baker, E. S., Schymanski, E., Renslow, R. S., Thomas, D., Causon, T. J., Webb, I., Hann, S., Smith, R. D., & Teeguarden, J. (2016) · Bioanalysis · doi:10.4155/bio-2016-0244 · Cited by 97
Methods, algorithms and tools in computational proteomics: A practical point of view
Matthiesen, R. (2007) · PROTEOMICS · doi:10.1002/pmic.200700116 · Cited by 105
“A long list of meth-ods for solving isobaric interference in mass spectra of complex peptide mixtures have been suggested: see Senko et al. [113], ZSCORE [114], ISOCONV [110], ESI-ISOCONV [115], Wang et al. [116], quadratic deisotoping [117], Matching [118], PepList [60], Zhang et al. [119], and…”
BackgroundHayashi, H., Takamune, N., Nirasawa, T., Aoki, M., Morishita, Y., Das, D., Koh, Y., Ghosh, A. K., Misumi, S., & Mitsuya, H. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1400027111 · Cited by 84
A method for calculating 16o/18o peptide ion ratios for the relative quantification of proteomes
Johnson, K. L., & Muddiman, D. C. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2003.11.016 · Cited by 86
“, that was derived by calculating an average amino acid from all proteins in the PIR database [24].”
MethodWoo, C. M., Felix, A., Byrd, W. E., Zuegel, D. K., Ishihara, M., Azadi, P., Iavarone, A. T., Pitteri, S. J., & Bertozzi, C. R. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b01053 · Cited by 85
Review of Peak Detection Algorithms in Liquid-Chromatography-Mass Spectrometry
Zhang, J., Gonzalez, E., Hestilow, T. J., Haskins, W. E., & Huang, Y. (2009) · Current Genomics · doi:10.2174/138920209789177638 · Cited by 102
“There exist various approaches [19-21] addressing the calculation of isotope patterns.”
BackgroundAdvanced Multidimensional Separations in Mass Spectrometry: Navigating the Big Data Deluge
May, J. C., & MCLEAN, J. A. J. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041734 · Cited by 93
Jehmlich, N., Schmidt, F., Hartwich, M., von Bergen�, M., Richnow, H. H., & Vogt, C. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3684 · Cited by 99
Preprocessing of tandem mass spectrometric data to support automatic protein identification
Gentzel, M., Köcher, T., Ponnusamy, S., & Wilm, M. S. (2003) · PROTEOMICS · doi:10.1002/pmic.200300486 · Cited by 83
FLASHDeconv: Ultrafast, High-Quality Feature Deconvolution for Top-Down Proteomics
Jeong, K., Kim, J., Gaikwad, M., Hidayah, S. N., Heikaus, L., Schlüter, H., & Kohlbacher, O. (2020) · Cell Systems · doi:10.1016/j.cels.2020.01.003 · Cited by 82
Jiang, Y., & Hofstadler, S. A. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(03)00024-1 · Cited by 82
Ong, S. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5998-3 · Cited by 106
Zhang, Z., Guan, S., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)82982-0 · Cited by 81
Payne, T. G., Southam, A. D., Arvanitis, T. N., & Viant, M. R. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.02.001 · Cited by 79
“SNR thresholds used include 3:1 [24–28] (the limit of detection), 5:1 [29], 10:1 [30] (the limit of quantification), and higher.”
MethodModulation of the Phagosome Proteome by Interferon-γ
Jutras, I., Houde, M., Currier, N., Boulais, J., Duclos, S., LaBoissière, S., Bonneil, E., Kearney, P., Thibault, P., Paramithiotis, E., et al. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700267-mcp200 · Cited by 78
Kafader, J. O., Durbin, K. R., Melani, R. D., Des Soye, B. J., Schachner, L. F., Senko, M. W., Compton, P. D., & Kelleher, N. L. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00797 · Cited by 76
Self-citationProtein-SIP in environmental studies
Jehmlich, N., Vogt, C., Lünsmann, V., Richnow, H. H., & von Bergen�, M. (2016) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.04.010 · Cited by 85
Strum, J. S., Nwosu, C. C., Hua, S. S., Kronewitter, S. R., Seipert, R. R., Bachelor, R. J., An, H. J., & Lebrilla, C. B. (2013) · Analytical Chemistry · doi:10.1021/ac4006556 · Cited by 80
Thorough Performance Evaluation of 213 nm Ultraviolet Photodissociation for Top-down Proteomics
Fornelli, L., Srzentić, K., Toby, T. K., Doubleday, P. F., Huguet, R., Mullen, C., Melani, R. D., Seckler, H. S., DeHart, C. J., Weisbrod, C. R., et al. (2019) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001638 · Cited by 79
“1 being the mass of averagine (74) and Ma the defined mass accuracy (tolerance) for fragment ion match; nPossFrags is instead a parameter that specifies the number of potential fragment types that can be used to assign a backbone cleavage.”
BackgroundMathematical tools in analytical mass spectrometry
Meija, J. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0298-4 · Cited by 75
Fundamentals and Advances of Orbitrap Mass Spectrometry
Hecht, E. S., Ščigelová, M., Eliuk, S. M., & Makarov, A. (2019) · Wiley eBooks · doi:10.1002/9780470027318.a9309.pub2 · Cited by 101
NITPICK: peak identification for mass spectrometry data
Renard, B. Y., Kirchner, M., Steen, H., Steen, J. A. J., & Hamprecht, F. A. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-355 · Cited by 87
“The calculation of the set of explanatory theoretical isotope distributions is based on fractional averagine, a mass error-free extension to the well-known averagine [8] model.”
MethodInfluentialResemann, A., Jabs, W., Wiechmann, A., Wagner, E., Colas, O., Evers, W., Belau, E., Vorwerg, L., Evans, C. S., Beck, A., et al. (2016) · mAbs · doi:10.1080/19420862.2015.1128607 · Cited by 79
“For data processing we used the SNAP II algorithm (a modification to the initially published algorithm) in combination with the Averagine concept to yield safe assignments of the antibody subunit monoisotopic MWs below the 1 ppm level.(30,29) This is despite the fact that the monoisotopic peak is 16 Da lower than the…”
BackgroundMethodPoly Specific trans -Acyltransferase Machinery Revealed via Engineered Acyl-CoA Synthetases
Koryakina, I., McArthur, J. B., Randall, S. M., Draelos, M. M., Musiol-Kroll, E. M., Muddiman, D. C., Weber, T., & Williams, G. J. (2012) · ACS Chemical Biology · doi:10.1021/cb3003489 · Cited by 73
Selenium-Encoded Isotopic Signature Targeted Profiling
Gao, J., Yang, F., Che, J., Han, Y., Wang, Y., Chen, N., Bak, D. W., Lai, S., Xie, X., Weerapana, E., et al. (2018) · ACS Central Science · doi:10.1021/acscentsci.8b00112 · Cited by 75
AlphaPept: a modern and open framework for MS-based proteomics
Strauss, M. T., Bludau, I., Zeng, W., Voytik, E., Ammar, C., Schessner, J. P., Ilango, R., Gill, M. L., Meier, F., Willems, S., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-46485-4 · Cited by 78
pTop 1.0: A High-Accuracy and High-Efficiency Search Engine for Intact Protein Identification
Sun, R.-X., Luo, L., Wu, L., Wang, R.-M., Zeng, W.-F., Chi, H., Liu, C., & He, S.-M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03963 · Cited by 71
Starke, R., Jehmlich, N., & Bastida, F. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2018.11.011 · Cited by 74
Protein‐based stable isotope probing (protein‐SIP) in functional metaproteomics
Seifert, J., Taubert, M., Jehmlich, N., Schmidt, F., Völker, U., Vogt, C., Richnow, H. H., & von Bergen�, M. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.21346 · Cited by 82
Cox, J., & Mann, M. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.05.007 · Cited by 85
“For this step, we assumed that the isotopic composition of the peptide corresponds to that of an average amino acid or “averagine” [11, 17 ].”
BackgroundpParse: A method for accurate determination of monoisotopic peaks in high‐resolution mass spectra
Yuan, Z. E., Liu, C., Wang, H., Sun, R., Fu, Y., Zhang, J., Wang, L., Chi, H., Li, Y., Xiu, L., et al. (2012) · PROTEOMICS · doi:10.1002/pmic.201100081 · Cited by 71
“Among them is the well-known averagine model [7], in which an averaged molecular formula is obtained from a protein database and used to estimate the peptide molecular formula, and then the distance between the experimental and the estimated isotopic distribution is calculated to determine the monoisotopic mass.”
MethodMayampurath, A. M., Wu, Y., Segu, Z. M., Mechref, Y. S., & Tang, H. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5059 · Cited by 76
Palmblad, M., Buijs, J., & Håkansson, P. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00301-4 · Cited by 73
A noise model for mass spectrometry based proteomics
Du, P., Stolovitzky, G. A., Horvatovich, P. L., Bischoff, R., Lim, J., & Suits, F. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn078 · Cited by 76
“However, the Poisson distribution is preferred because it is regarded as a reasonable approximation of the detection process (Chernushevich, et al., 2001; Senko, et al., 1995 ).”
MethodDetection of RET proto-oncogene codon 634 mutations using mass spectrometry
Little, D. P., Braun, A., Darnhofer-Demar, B., Frilling, A., Li, Y., McIver, R. T., & Köster, H. (1997) · Journal of Molecular Medicine · doi:10.1007/s001090050160 · Cited by 68
“It was for this most abundant isotope peak, which was determined by performing a χ2 analysis comparing the experimental versus a theoretical distribution [18], for which molecular weights are reported.”
MethodValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLaffertycor, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Senko, Michael W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 6
- Issue
- 4
- Pages
- 229-233
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2086502504
- Semantic Scholar
- 94b2dabffe606cc05171d713f5c8c92da73345ca
- Cited by
- 451
- References
- 24
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 19 · 2023: 12 · 2022: 11 · 2021: 19 · 2020: 28 · 2019: 18 · 2018: 16 · 2017: 23 · 2016: 20 · 2015: 17 · 2014: 21 · 2013: 22 · 2012: 15
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotopic distribution, large biomolecules, electrospray ionization, Fourier transform mass spectrometry, statistical tests, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.