CoChat

An effective method for fast determination of artemisinin in Artemisia annua L. by high performance liquid chromatography with evaporative light scattering detection

Open access
Liu, Chun-Zhao, Zhou, Hua-Ying, Zhao, Yan · 2007 · Analytica Chimica Acta
Cited by 69

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Artemisinin isolated from the aerial parts of Artemisia annua L., is a promising and potent antimalarial drug, which meets the dual challenge posed by drug-resistant parasites and rapid progression of malarial illness. The aim of the current study was to develop a reliable and fast analytical procedure for the determination of artemisinin in A. annua using high performance liquid chromatography (HPLC) with evaporative light scattering detection (ELSD) in couple with microwave-assisted extraction (MAE) as an efficient sample preparation technique. The HPLC conditions were Agilent C18 column using water:acetonitrile (40:60 v/v) mixture as mobile phase at a flow rate of 1 mL min(-1). ELSD conditions were optimized at nebulizer-gas flow rate of 2.0 L min(-1) and drift tube temperature of 70 degrees C under the impactor off-mode, and the gain was set at 2. Afterwards, method validation system for HPLC-ELSD analysis was developed. Calibration range was 0.2-1.0 mg mL(-1) and correlation coefficient r was above 0.9990. Precision experiments showed relative standard deviation (R.S.D.) of retention time was less than 0.5% and R.S.D. of peak area was less than 1.30%. Inter-day and intra-day variabilities showed that R.S.D. was ranged from 1.01% to 4.66%. Limit of detection was less than 40 microg mL(-1) and limit of quantification was less than 100 microg mL(-1). Accuracy validation showed that average recovery was between 98.23% and 104.97%. The developed analytical procedure was successfully applied to determine the contents of artemisinin in the different parts of A. annua plants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.aca.2006.08.038

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
Liu, C.-Z., Zhou, H.-Y., & Zhao, Y.
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2007-01
Volume
581
Issue
2
Pages
298-302
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2058902441
Cited by
69
References
1
FWCI
6.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An effective method for fast determination of artemisinin in Artemisia annua L. by high performance liquid chromatography with evaporative light scattering detection. https://app.cochat.ai/papers/10.1016/j.aca.2006.08.038
The paper
Liu, C.-Z., Zhou, H.-Y., & Zhao, Y. (2007). An effective method for fast determination of artemisinin in Artemisia annua L. by high performance liquid chromatography with evaporative light scattering detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2006.08.038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.