The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Direct ink writing of highly porous and strong glass scaffolds for load-bearing bone defects repair and regeneration
Open accessAbstract
The quest for synthetic materials to repair load-bearing bone lost because of trauma, cancer, or congenital bone defects requires development of porous and high-performance scaffolds with exceptional mechanical strength. However, the low mechanical strength of porous bioactive ceramic and glass scaffolds, compared with that of human cortical bone, has limited their use for these applications. In the present work, bioactive 6P53B glass scaffolds with superior mechanical strength were fabricated using a direct ink writing technique. The rheological properties of Pluronic® F-127 (referred to hereafter simply as F-127) hydrogel-based inkswere optimized for the printing of features as fine as 30 μm and of the three-dimensional scaffolds. The mechanical strength and in vitro degradation of the scaffolds were assessed in a simulated body fluid (SBF). The sintered glass scaffolds show a compressive strength (136 ± 22 MPa) comparable to that of human cortical bone (100-150 MPa), while the porosity (60%) is in the range of that of trabecular bone (50-90%).The strength is ~100 times that of polymer scaffolds and 4–5 times that of ceramic and glass scaffolds with comparable porosities. Despite the strength decrease resulting from weight loss during immersion in an SBF, the value (77 MPa) is still far above that of trabecular bone after three weeks. The ability to create both porous and strong structures opens a new avenue for fabricating scaffolds for load-bearing bone defect repair and regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Cellular solids: Structure and properties
Wolcott, M. P. (1990) · Materials Science and Engineering: A · doi:10.1016/0921-5093(90)90295-e · Cited by 5,926
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
A Mechanism for Non-Newtonian Flow in Suspensions of Rigid Spheres
Krieger, I. M., & Dougherty, T. J. (1959) · Transactions of the Society of Rheology · doi:10.1122/1.548848 · Cited by 3,402
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
Third-Generation Biomedical Materials
Hench, L. L., & Polak, J. M. (2002) · Science · doi:10.1126/science.1067404 · Cited by 2,789
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Hench, L. L. (1998) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1998.tb02540.x · Cited by 2,652
Freezing as a Path to Build Complex Composites
Deville, S., Saiz, E., Nalla, R. K., & Tomsia, A. P. (2006) · Science · doi:10.1126/science.1120937 · Cited by 1,900
Self-citationTough, Bio-Inspired Hybrid Materials
Munch, E., Launey, M. E., Alsem, D. H., Saiz, E., Tomsia, A. P., & Ritchie, R. O. (2008) · Science · doi:10.1126/science.1164865 · Cited by 1,822
Self-citationBioactive glass in tissue engineering
Rahaman, M. N., Day, D. E., Sonny Bal, B., Fu, Q., Jung, S. B., Bonewald, L. F., & Tomsia, A. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.03.016 · Cited by 1,794
Self-citationKonsistenzmessungen von Gummi-Benzollösungen
Herschel, W. H., & Bulkley, R. (1926) · Kolloid-Zeitschrift · doi:10.1007/bf01432034 · Cited by 1,499
45S5 Bioglass®-derived glass–ceramic scaffolds for bone tissue engineering
Chen, Q. Z., Thompson, I. D., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.025 · Cited by 1,241
Xynos, I. D., Edgar, A. J., Buttery, L. D. K., Hench, L. L., & Polak, J. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<151::aid-jbm1001>3.0.co;2-d · Cited by 1,235
Omnidirectional Printing of Flexible, Stretchable, and Spanning Silver Microelectrodes
Ahn, B. Y., Duoss, E. B., Motala, M. J., Guo, X., Park, S.-I., Xiong, Y., Yoon, J., Nuzzo, R. G., Rogers, J. A., & Lewis, J. A. (2009) · Science · doi:10.1126/science.1168375 · Cited by 1,191
Martin, R. B., Burr, D. B., Sharkey, N. A., & Fyhrie, D. P. (2015) · doi:10.1007/978-1-4939-3002-9 · Cited by 1,159
Hench, L. L., & Wilson, J. (1984) · Science · doi:10.1126/science.6093253 · Cited by 982
Martin, R. B., Burr, D. B., & Sharkey, N. A. (1998) · Springer eBooks · doi:10.1007/978-1-4757-2968-9 · Cited by 976
Direct Ink Writing of Three‐Dimensional Ceramic Structures
Lewis, J. A., Smay, J. E., Stuecker, J., & Cesarano, J. (2006) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2006.01382.x · Cited by 823
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Optimising bioactive glass scaffolds for bone tissue engineering
Jones, J. R., Ehrenfried, L. M., & Hench, L. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.017 · Cited by 711
Bioactive glass scaffolds for bone tissue engineering: state of the art and future perspectives
Fu, Q., Saiz, E., Rahaman, M. N., & Tomsia, A. P. (2011) · Materials Science and Engineering: C · doi:10.1016/j.msec.2011.04.022 · Cited by 703
Self-citationFu, Q., Rahaman, M. N., Fu, H., & Liu, X. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32824 · Cited by 414
Self-citationCoating of VEGF-releasing scaffolds with bioactive glass for angiogenesis and bone regeneration
Kent Leach, J., Kaigler, D., Wang, Z., Krebsbach, P. H., & Mooney, D. J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.033 · Cited by 411
Direct writing of three-dimensional webs
Gratson, G. M., Xu, M., & Lewis, J. A. (2004) · Nature · doi:10.1038/428386a · Cited by 389
Directed Colloidal Assembly of 3D Periodic Structures
Smay, J. E., Gratson, G. M., Shepherd, R. F., Cesarano, J., & Lewis, J. A. (2002) · Advanced Materials · doi:10.1002/1521-4095(20020916)14:18<1279::aid-adma1279>3.0.co;2-a · Cited by 388
The mechanical properties of natural materials. I. Material property charts
Ashby, M. F., Gibson, L. J., Wegst, U., & Olive, R. (1995) · Proceedings of the Royal Society of London. Series A: Mathematical and Physical Sciences · doi:10.1098/rspa.1995.0075 · Cited by 339
Sintering and robocasting of β-tricalcium phosphate scaffolds for orthopaedic applications
Miranda, P., Saiz, E., Gryn, K., & Tomsia, A. P. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.02.004 · Cited by 304
Self-citationFu, Q., Rahaman, M. N., Sonny Bal, B., Brown, R. F., & Day, D. E. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.04.019 · Cited by 302
Self-citationConcentrated hydroxyapatite inks for direct-write assembly of 3-D periodic scaffolds
Michna, S., Wu, W., & Lewis, J. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.040 · Cited by 266
Bioinspired Strong and Highly Porous Glass Scaffolds
Fu, Q., Saiz, E., & Tomsia, A. P. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002030 · Cited by 252
Self-citationDirect write assembly of calcium phosphate scaffolds using a water-based hydrogel
Franco, J., Hunger, P., Launey, M. E., Tomsia, A. P., & Saiz, E. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.031 · Cited by 217
Self-citationProangiogenic Potential of a Collagen/Bioactive Glass Substrate
Leu, A., & Leach, J. K. (2008) · Pharmaceutical Research · doi:10.1007/s11095-007-9508-9 · Cited by 217
Buscall, R., McGowan, J. I., & Morton‐Jones, A. J. (1993) · Journal of Rheology · doi:10.1122/1.550387 · Cited by 213
Rheological behavior of a concentrated suspension: A solid rocket fuel simulant
Kalyon, D. M., Yaras, P., Aral, B., & Yilmazer, U. (1993) · Journal of Rheology · doi:10.1122/1.550435 · Cited by 203
Nanoparticle Inks for Directed Assembly of Three‐Dimensional Periodic Structures
Li, Q., & Lewis, J. A. (2003) · Advanced Materials · doi:10.1002/adma.200305413 · Cited by 168
Shear thinning and shear thickening of concentrated ceramic suspensions
Bergström, L. (1998) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(97)00133-7 · Cited by 152
Russias, J., Saiz, E., Deville, S., Gryń, K., Liu, G., Nalla, R. K., & Tomsia, A. P. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31237 · Cited by 147
Self-citationSmart Hydrogels for in Situ Generated Implants
Cohn, D., Sosnik, A., & Garty, S. (2005) · Biomacromolecules · doi:10.1021/bm0495250 · Cited by 107
Erratum: Porous scaffold design for tissue engineering
Hollister, S. J. (2006) · Nature Materials · doi:10.1038/nmat1683 · Cited by 93
Fu, Q., Rahaman, M. N., Bal, B. S., & Brown, R. F. R. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32637 · Cited by 87
Self-citationImpact of bone geometry on effective properties of bone scaffolds
McIntosh, L. D., Cordell, J., & Johnson, A. J. W. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.09.010 · Cited by 33
Cited by
Bone tissue engineering using 3D printing
Bose, S., Vahabzadeh, S., & Bandyopadhyay, A. (2013) · Materials Today · doi:10.1016/j.mattod.2013.11.017 · Cited by 1,866
Additive Manufacturing of Ceramics: Issues, Potentialities, and Opportunities
Zocca, A., Colombo, P., Gomes, C. M., & Günster, J. (2015) · Journal of the American Ceramic Society · doi:10.1111/jace.13700 · Cited by 1,115
Multimaterial magnetically assisted 3D printing of composite materials
Kokkinis, D., Schaffner, M., & Studart, A. R. (2015) · Nature Communications · doi:10.1038/ncomms9643 · Cited by 848
Designing Biomaterials for 3D Printing
Guvendiren, M., Molde, J., Soares, R. M. D., & Kohn, J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00121 · Cited by 732
A review of bioactive glasses: Their structure, properties, fabrication and apatite formation
Kaur, G., Pandey, O. P., Singh, K., Homa, D., Scott, B., & Pickrell, G. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34690 · Cited by 628
Metadata
- Authors
- Fu, Q., Saiz, E., & Tomsia, A. P.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2011-10
- Volume
- 7
- Issue
- 10
- Pages
- 3547-3554
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2169320864
- Cited by
- 366
- References
- 45
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.