Cited by 53Numerical methods in inverse problemsControl Systems and IdentificationNon-Invasive Vital Sign Monitoring

Deconvolving an estimate of breath measured blood alcohol concentration from biosensor collected transdermal ethanol data

Open access
Dumett, M.A., Rosen, I.G., Sabat, J., Shaman, A., Tempelman, L., Wang, C., Swift, R.M.·2008·Applied Mathematics and Computation

Abstract

Biosensor measurement of transdermal alcohol oncentration in perspiration exhibits significant variance from subject to subject and device to device. Short duration data collected in a controlled clinical setting is used to calibrate a forward model for ethanol transport from the blood to the sensor. The calibrated model is then used to invert transdermal signals collected in the field (short or long duration) to obtain an estimate for breath measured blood alcohol concentration. A distributed parameter model for the forward transport of ethanol from the blood through the skin and its processing by the sensor is developed. Model calibration is formulated as a nonlinear least squares fit to data. The fit model is then used as part of a spline based scheme in the form of a regularized, non-negatively constrained linear deconvolution. Fully discrete, steepest descent based schemes for solving the resulting optimization problems are developed. The adjoint method is used to accurately and efficiently compute requisite gradients. Efficacy is demonstrated on subject field data.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.amc.2007.07.026

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • BrAC instruments calculate BAC by following Henry's law, but may compromise accuracy because results can be easily affected by humidity, temperature, and individual traits.

    “BrAC instruments calculate BAC by following Henry's law, but may compromise accuracy since the results can be easily affected by humidity, temperature, and individual traits.7,8”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. [6]Dumett M, Rosen IG, Sabat J, Shaman A, Tempelman L, Wang C, Swift R . Four distributed parameter models for estimating, simulating and inverting the transdermal transport of alcohol. Modeling and Simulation Laboratory, University of Southern California, Report Series, 05-01; 2005. http://www-rcf.usc.edu/~dumett/publications.html. [Google Scholar]
  2. [17]Nyman E, Palmlov A. The elimination of ethyl alcohol in sweat. Scand. Arch. Physiol. 1936;74:155–159. [Google Scholar]
  3. [22]Shamam A. Modeling and deconvolution of alcohol transport through human skin employing a new fully discrete parameter estimation framework for parabolic and hyperbolic distributed parameter systems. Ph.D. Thesis. Department of Mathematics, University of Southern California; 2006. May, [Google Scholar]
  4. [29]Vander AJ, Sherman JH, Luciano DS. The mechanics of the body function. 2nd ed. New York: Mc-Graw Hill; 1975. Human Physiology. [Google Scholar]

Cited by

Sorted by citations

Authors
Dumett, M. A., Rosen, I. G., Sabat, J., Shaman, A., Tempelman, L., Wang, C., & Swift, R. M.
Affiliations
  • University of Southern California (US)
  • Giner (United States) (US)
  • Brown University (US)
Corresponding author
Dumett, M.A.
Venue
Applied Mathematics and Computation
Publisher
Elsevier BV
Published
2008-03
Volume
196
Issue
2
Pages
724-743
ISSN
0096-3003 (ISSN-L)
OpenAlex
W1988263497
Cited by
53
References
28
Citations by year
2025: 2 · 2024: 2 · 2023: 3 · 2022: 7 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 11 · 2017: 4 · 2016: 3 · 2015: 2 · 2014: 4 · 2013: 2 · 2012: 2
FWCI
1.35
Type
journal article
Language
en
Open access
Locations
  • Applied Mathematics and Computation (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institute on Alcohol Abuse and Alcoholism (N01AA33002)
  • National Institutes of Health
Topics
  • Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
  • Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
blood alcohol concentration, distributed parameter model, nonlinear least squares, steepest descent optimization, adjoint method, inverse problems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review