Cited by 76Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAnalytical Chemistry and Sensors

Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat

Open access
Bhide, Ashlesha, Muthukumar, Sriram, Saini, Amreek, Prasad, Shalini·2018·Scientific Reports

Abstract

A lancet-free, label-free biosensor for simultaneous detection of sweat glucose and alcohol was demonstrated using zinc oxide thin films integrated into a nanoporous flexible electrode system. Sensing was achieved from perspired human sweat at low volumes (1–3 μL), comparable to ambient conditions without external stimulation. Zinc oxide thin film electrodes were surface functionalized with alcohol oxidase enzyme and with glucose oxidase enzyme towards developing an affinity biosensor specific to the physiological relevant range of alcohol comprising of 0–2 drinks (0–50 mg/dl) and physiologically relevant range of glucose ranging from hypo- to hyper-glycaemia (50–130 mg/dl) in perspired human sweat. Sensing was achieved by measuring impedance changes associated with alcohol and glucose binding onto the sensor interface using electrochemical impedance spectroscopy with a dynamic range from 0.01–200 mg/dl and a limit of detection of 0.01 mg/dl for alcohol in human sweat. Sensor calibration in synthetic sweat containing interferents (25–200 mg/dl) and comparison using regression and Bland-Altman analysis of sweat sensor performance was done with BACtrack®. Combinatorial detection of glucose and ethanol in perspired human sweat and comparison of sweat sensor performance with Accu-Chek® blood glucose monitoring system that we expect would be relevant for pre-diabetics and diabetics for monitoring their glucose levels and alcohol consumption.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-24543-4

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Various materials have been used as working electrodes, such as noble metals (Au and Ag), metallic oxides, graphene, and carbon black.

    “Various materials have been used as working electrodes, such as noble metal (Au and Ag) (20–22), metallic oxides (23, 24), graphene (25, 26), and carbon black (27).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bhide, A., Muthukumar, S., Saini, A., & Prasad, S.
Affiliations
The University of Texas at Dallas (US)
Corresponding author
Prasad, Shalini
Venue
Scientific Reports
Published
2018-04-25
Volume
8
Issue
1
Pages
6507-6507
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2802212723
Cited by
76
References
36
Citations by year
2026: 2 · 2025: 5 · 2024: 10 · 2023: 9 · 2022: 18 · 2021: 10 · 2020: 13 · 2019: 7 · 2018: 2
FWCI
3.06
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • National Institutes of Health
  • National Institute on Alcohol Abuse and Alcoholism (R43AA026114)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
alcohol detection, glucose monitoring, ZnO thin films, alcohol oxidase, glucose oxidase, label-free biosensor, electrochemical impedance spectroscopy, diabetes monitoring, prediabetes
MeSH terms
Wearable Electronic Devices, Ethanol, Blood Glucose, Electrodes, Glucose, Glucose Oxidase, Humans, Sweat, Zinc Oxide, Blood Glucose Self-Monitoring, Biosensing Techniques, Electric Impedance, Electrochemical Techniques, Dielectric Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review