CoChat

True Resistant Hypertension: Is it Possible to Be Recognized in the Office?

MUXFELDT, E, BLOCH, K, DAROCHANOGUEIRA, A, SALLES, G · 2005 · American Journal of Hypertension
Cited by 106

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: True resistant hypertension (RH) is defined as uncontrolled office and ambulatory blood pressure (BP) in spite of an optimal regimen with at least three antihypertensive drugs. The aim of this study is to identify, in the office, clinical, laboratory, electrocardiographic, and echocardiographic variables associated with the occurrence of true RH. METHODS: These variables were recorded in a cross-sectional study involving 497 resistant hypertensive patients diagnosed by ambulatory BP monitoring as true RH (63.0%) or white coat RH (37.0%). Statistical analysis included bivariate and multivariate logistic regression. RESULTS: In bivariate analysis, true RH patients were younger, more frequently men, and had significantly higher office BP than white coat RH patients. They also had higher prevalence of physical inactivity, heart failure, and retinopathy, higher fasting glycemia, 24-h proteinuria and albuminuria, and lower serum potassium. In addition, these patients had higher electrocardiographic Sokolow and Cornell voltages and echocardiographic left ventricular mass index and hypertrophy. In multivariate logistic regression the variables best associated with true RH were male sex (P = .026), office systolic BP > or =180 mm Hg (P = .016), fasting glycemia > or =7.0 mmol/L (P = .042), serum potassium <4.5 mmol/L (P = .037), abnormal microalbuminuria (P < .001), adjusted Cornell voltage > or =2.6 mV (P = .002), and echocardiographic left ventricular hypertrophy (P = .009). In an alternative simpler model, proteinuria substituted microalbuminuria and echocardiographic data was excluded. Both predictive models have areas under receiver operating characteristic curve of 0.70. CONCLUSIONS: True RH can be recognized in the office in selected RH patients. We propose a simple scoring system with these variables that can be used in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.amjhyper.2005.06.013

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 106

Metadata

Authors
MUXFELDT, E., BLOCH, K., DAROCHANOGUEIRA, A., & SALLES, G.
Venue
American Journal of Hypertension
Published
2005-12
Volume
18
Issue
12
Pages
1534-1540
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2050458058
Cited by
106
References
4
FWCI
3.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: True Resistant Hypertension: Is it Possible to Be Recognized in the Office? https://app.cochat.ai/papers/10.1016/j.amjhyper.2005.06.013
The paper
MUXFELDT, E., BLOCH, K., DAROCHANOGUEIRA, A., & SALLES, G. (2005). True Resistant Hypertension: Is it Possible to Be Recognized in the Office? American Journal of Hypertension. https://doi.org/10.1016/j.amjhyper.2005.06.013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.