CoChat

Home Blood Pressure Is as Reliable as Ambulatory Blood Pressure in Predicting Target-Organ Damage in Hypertension

Open access
STERGIOU, G, ARGYRAKI, K, MOYSSAKIS, I, MASTORANTONAKIS, S, ACHIMASTOS, A, KARAMANOS, V, ROUSSIAS, L · 2007 · American Journal of Hypertension
Cited by 109

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Our objective was to assess the value of home blood pressure (BP) monitoring in comparison to office BP measurements and ambulatory monitoring in predicting hypertension-induced target-organ damage. METHODS: Sixty-eight untreated patients with hypertension with at least two routine prestudy office visits were included (mean age, 48.6 +/- 9.1 [SD] years; 50 men). Office BP was measured in two study visits, home BP was measured for 6 workdays, and ambulatory BP was monitored for 24 h. All BP measurements were obtained using validated electronic devices. Target-organ damage was assessed by measuring the echocardiographic left-ventricular mass index (LVMI), urinary albumin excretion rate (AER) in two overnight urine collections, and carotid-femoral pulse-wave velocity (PWV) (Complior device; Colson, Garges-les-Gonesse, Paris, France). RESULTS: The correlation coefficients of LVMI with office BP were 0.24/0.15 (systolic/diastolic), with home BP 0.35/0.21 (systolic, P < .01), and with 24-h ambulatory BP 0.23/0.19, awake 0.21/0.16, and asleep 0.28/0.26 (asleep, both P < .05). The correlation coefficients of AER with office BP were 0.24/0.31 (diastolic, P < .05), with home BP 0.28/0.26 (both P < .05), and with 24-h ambulatory BP 0.25/0.24, awake 0.24/0.25 (diastolic, P < .05), and asleep 0.26/0.18 (systolic, P < .05). There was a trend for negative correlations between PWV and diastolic BP measurements (not significant). In multiple-regression models assessing independent predictors of each of the three indices of target-organ damage, systolic home BP and age were the only independent predictors of increased LVMI that reached borderline statistical significance. CONCLUSIONS: These data suggest that home BP is as reliable as ambulatory monitoring in predicting hypertension-induced target-organ damage, and is superior to carefully taken office measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.amjhyper.2006.12.013

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 109

Metadata

Authors
STERGIOU, G., ARGYRAKI, K., MOYSSAKIS, I., MASTORANTONAKIS, S., ACHIMASTOS, A., KARAMANOS, V, & ROUSSIAS, L.
Venue
American Journal of Hypertension
Published
2007-06
Volume
20
Issue
6
Pages
616-621
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2005153205
Cited by
109
References
8
FWCI
5.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home Blood Pressure Is as Reliable as Ambulatory Blood Pressure in Predicting Target-Organ Damage in Hypertension. https://app.cochat.ai/papers/10.1016/j.amjhyper.2006.12.013
The paper
STERGIOU, G., ARGYRAKI, K., MOYSSAKIS, I., MASTORANTONAKIS, S., ACHIMASTOS, A., KARAMANOS, V, & ROUSSIAS, L. (2007). Home Blood Pressure Is as Reliable as Ambulatory Blood Pressure in Predicting Target-Organ Damage in Hypertension. American Journal of Hypertension. https://doi.org/10.1016/j.amjhyper.2006.12.013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.