Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
James, P. A., Oparil, S., Carter, B. L., Cushman, W. C., Dennison-Himmelfarb, C., Handler, J., Lackland, D. T., LeFevre, M. L., MacKenzie, T. D., Ogedegbe, O., et al. (2014) · JAMA · doi:10.1001/jama.2013.284427 · Cited by 7,950
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021 · cited 1×
“Parati et al (2014) 16 European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring.”
Backgroundde la Sierra, A., Segura, J., Banegas, J. R., Gorostidi, M., de la Cruz, J. J., Armario, P., Oliveras, A., & Ruilope, L. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.168948 · Cited by 809
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Lovibond, K., Jowett, S., Barton, P., Caulfield, M., Heneghan, C., Hobbs, F. R., Hodgkinson, J., Mant, J., Martin, U., Williams, B., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61184-7 · Cited by 311
Ambulatory Blood Pressure for Cardiovascular Risk Stratification
Verdecchia, P., Angeli, F., & Cavallini, C. (2007) · Circulation · doi:10.1161/circulationaha.107.697086 · Cited by 59
Cited by
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“Ambulatory BP monitoring allows getting BP readings several times a day, which is ideal to monitoring high blood pressure (hypertension), one of the greatest threats to the global burden of diseases, improving cardiovascular diseases prediction [13,24].”
BackgroundBlekkenhorst, L. C., Bondonno, N. P., Liu, A. H., Ward, N. C., Prince, R. L., Lewis, J. R., Devine, A., Croft, K. D., Hodgson, J. M., & Bondonno, C. P. (2018) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqx046 · Cited by 89
Solano López, A. L. (2018) · Worldviews on Evidence-Based Nursing · doi:10.1111/wvn.12319 · Cited by 61
Siervo, M., Lara, J., Jajja, A., Sutyarjoko, A., Ashor, A. W., Brandt, K., Qadir, O., Mathers, J. C., Benjamin, N., Winyard, P. G., et al. (2015) · Nitric Oxide · doi:10.1016/j.niox.2015.04.007 · Cited by 52
Metadata
- Authors
- Turner, J. R., Viera, A. J., & Shimbo, D.
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 128
- Issue
- 1
- Pages
- 14-20
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W1984125872
- Cited by
- 128
- References
- 7
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review. https://app.cochat.ai/papers/10.1016/j.amjmed.2014.07.021
- The paper
- Turner, J. R., Viera, A. J., & Shimbo, D. (2015). Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review. The American Journal of Medicine. https://doi.org/10.1016/j.amjmed.2014.07.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.