Cited by 101Icing and De-icing TechnologiesRefrigeration and Air Conditioning TechnologiesHeat Transfer and Optimization

A new time- and space-dependent model for predicting frost formation

Cui, J., Li, W.Z., Liu, Y., Jiang, Z.Y.·2011·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2010.09.022

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cui et al. [22,24] proposed a frost mass transfer model based on nucleation theory to model the frosting process on flat plates and fin-and-tube heat exchangers.

    “Cui et al. [22,24] proposed a frost mass transfer model based on nucleation theory to model the frosting process on flat plates and fin-and-tube heat exchangers.”
  • Some frosting models have been coupled with multiphase flow models in CFD simulations [5,22,23].

    “Some frosting models have been coupled with multiphase flow models in CFD simulations [5,22,23].”
  • The maximum frost thickness appears at the leading edge of the flat plate during the early stage of frosting, but it may move along the air flow direction as frosting progresses.

    “although the maximum frost thickness appeared at the leading edge of the flat plate during the early stage of frosting period, it may move along the air flow direction as frosting progressed.”
  • Both frost thickness and density decrease consistently with an increase in the distance from the leading edge of a flat plate with a fixed surface temperature.

    “both frost thickness and density were decreased consistently with an increase in the distance from the leading edge of the flat plate.”
  • Cui et al. [83] found that when air velocity is higher than 1.5 m/s, the average frost thickness on flat plates with a fixed surface temperature decreases with an increase in air velocity.

    “However, Cui et al. [83] indicated that the average thickness was increased with an increase in air velocity when the air velocity was lower than 1.5 m/s, but decreased with an increase in air velocity when the air velocity was higher than 1.5 m/s.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Cui, J., Li, W. Z., Liu, Y., & Jiang, Z. Y.
Affiliations
  • Dalian University of Technology (CN)
  • Rina Services (Italy) (IT)
Corresponding author
Li, W.Z.
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2011-03
Volume
31
Issue
4
Pages
447-457
ISSN
1359-4311 (ISSN-L)
OpenAlex
W1983257470
Cited by
101
References
25
Citations by year
2026: 10 · 2025: 7 · 2024: 11 · 2023: 11 · 2022: 10 · 2021: 8 · 2020: 5 · 2019: 6 · 2018: 13 · 2017: 8 · 2016: 3 · 2015: 3 · 2014: 2 · 2013: 1 · 2012: 1
FWCI
2.51
Type
journal article
Language
en
Open access
closed
Locations
Applied Thermal Engineering (publishedVersion)
Funders
National Natural Science Foundation of China (50976017, 50736001)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
Keywords
frost formation, frost growth, nucleation theory, frost layer, mass transfer, water vapor, inlet air velocity, surface structure, frost density, frost thickness, computational fluid dynamics model

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review