Experimental study of frost accumulation on fan-supplied tube-fin evaporators
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In experimental tests, frost mass is typically estimated using the humidity ratio difference between the inlet and the outlet, as demonstrated in [17] and [20].”
In the citing paper
“In addition, most experimental tests have been con ducted on horizontally assembled plates [12 -17] or fin-and-tube heat exchangers under horizontal air flow conditions [18 -21].”
In the citing paper
“The frost layer and air-side pressure drop have a strong relationship [34].”
From Experimental investigation on an air source heat pump system with a novel anti-frosting evaporator (2023) · cites this paper as [34]
In the citing paper
“Figure 5 compares the time evolution of the calculated cooling capacity (Fig. 5a) and air flow rate (Fig. 5b) with the experimental counterparts, where one can note that the model is able to follow the experimental trends quite satisfactorily, especially after the early transients (i.e., from 10 min on), where the frost formation effects are more perceptible”
From Optimal design of fan-supplied tube-fin evaporators subjected to frosting conditions aiming at minimum energy consumption (2018) · cites this paper as [26]
In the citing paper
“The model validation exercise for the frosting evaporator was carried out using data from [26].”
From Optimal design of fan-supplied tube-fin evaporators subjected to frosting conditions aiming at minimum energy consumption (2018) · cites this paper as [26]
In the citing paper
“Another real-time measuring method for the total frost accumulation is calculating with the changing of air water content at inlet and outlet air of the outdoor heat exchanger, or evaporator [127].”
From Review on the measurement and calculation of frost characteristics (2018) · cites this paper as [127]
In the citing paper
“Some experimental results showed the louver fin had the most frost accumulation amount and the greatest air pressure drop, followed the wavy and flat fins.”
From Effect of fin types of outdoor fan-supplied finned-tube heat exchanger on periodic frosting and defrosting performance of a residential air-source heat pump (2014) · cites this paper as Silva and Hermes [1]
In the citing paper
“Under certain outdoor winter conditions, frost forms on the outdoor finned-tube heat exchanger and decreases its thermal performance due to the combined effects of the increased thermal resistance and the decreased airflow rate caused by frost blocking.”
Citations
Cites
Thermal environmental engineering
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)90922-5 · Cited by 927
A study of frost growth and densification on flat surfaces
Hermes, C. J. L., Piucco, R. O., Barbosa, J. R., & Melo, C. (2009) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2008.10.006 · Cited by 257 · cited 1×
“…frost mass. Supercooling levels (i.e., the temperature difference between the evaporator surface and the dew-point of the entering air flow, see Hermes et al., 2009) of 3.5, 5.0, 10.0 and 14.5°C were used in combination with different air flow rates and evaporator geometries (i.e., different…”
MethodInfluentialSelf-citationXia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 152 · cited 1×
“In a first attempt to fill this gap, Xia et al. (2006) studied the frosting, defrosting and re-frosting processes taking place on louvered-fin flat-tube heat exchangers and observed that the overall heat transfer coefficient decreases due to the reduction in the air flow rate and also to the…”
BackgroundEffect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger
Jhee, S., Lee, K.-S., & Kim, W.-S. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00008-7 · Cited by 149
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
Fin spacing optimization of a fin-tube heat exchanger under frosting conditions
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.01.016 · Cited by 81
Zhang, P., & Hrnjak, P. S. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.006 · Cited by 75
Fan supplied heat exchanger fin performance under frosting conditions
Chen, H., Thomas, L., & Besant, R. W. (2003) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00011-7 · Cited by 59
Lenic, K., Trp, A., & Frankovic, B. (2009) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.12.030 · Cited by 38
Bejan, A., Vargas, J. V. C., & Lim, J. S. (1994) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(94)90087-6 · Cited by 33
Research works printed but not linked: 4
- Stoecker, 1957, How frost formation on coils affects refrigeration systems, Refrigerating Engineering, 65
- Kondepudi, 1987, The effect of frost growth on extended surface heat exchanger performance: a review, ASHRAE Transactions, 93, 258
- Rite, 1991, The effect of frost accumulation on the performance of domestic refrigerator-freezer finned-tube evaporator coils, ASHRAE Transactions, 97, 428
- Ogawa, 1993, Performance improvement of plate fin-and-tube heat exchangers under frosting conditions, ASHRAE Transactions, 99, 762
Cited by
Sorted by citations
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384
Review on the measurement and calculation of frost characteristics
Song, M., & Dang, C. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.03.094 · Cited by 212
Frosting characteristics on hydrophobic and superhydrophobic surfaces: A review
Kim, M.-H., Kim, H., Lee, K.-S., & Kim, D. R. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.01.067 · Cited by 171
Tang, J., Gong, G., Su, H., Wu, F., & Herman, Č. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.02.042 · Cited by 122
State-of-the-art review of frost deposition on flat surfaces
Léoni, A., Mondot, M., Durier, F., Revellin, R., & Haberschill, P. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.04.004 · Cited by 103
Metadata
- Authors
- da Silva, D. L., Hermes, C. J. L., & Melo, C.
- Affiliations
- Universidade Federal do Paraná (BR)
- Universidade Federal de Santa Catarina (BR)
- Corresponding author
- Hermes, Christian J.L.
- ORCID
- Melo, Claudio
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2011-05
- Volume
- 31
- Issue
- 6-7
- Pages
- 1013-1020
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2079477035
- Cited by
- 118
- References
- 15
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 11 · 2023: 10 · 2022: 8 · 2021: 10 · 2020: 4 · 2019: 14 · 2018: 10 · 2017: 10 · 2016: 4 · 2015: 3 · 2014: 9 · 2013: 2 · 2012: 2
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Purdue e-Pubs (Purdue University System) (submittedVersion)
- Funders
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Embraco
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Keywords
- frost accumulation, fan characteristics, wavy fins, louvered fins, supercooling, air-side pressure drop, cooling capacity, compact heat exchangers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review