Cited by 58Refrigeration and Air Conditioning TechnologiesHeat Transfer and OptimizationIcing and De-icing Technologies

Effect of frost morphology on the thermal-hydraulic performance of fan-supplied tube-fin evaporators

da Silva, Diogo L., Melo, Cláudio, Hermes, Christian J.L.·2017·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2016.09.165

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In fan-supplied tube-fin evaporators, the air flow rate varies as frost accumulates over the coil, blocking the air passage.

    “although in fan-supplied tube-fin evaporators the air flow rate varies as frost accumulates over the coil, blocking the air passage [10, 11].”
  • Airflow reduction due to a fan constraint is the main cause of evaporator capacity depletion, while the additional thermal resistance related to the frost layer plays a minor role.

    “recent studies have pointed out that the airflow reduction due to a fan constraint is the main cause of the evaporator capacity depletion, while the additional thermal resistance related to the frost layer plays a minor role ( Padhmanabhan et al., 2011; Da Silva et al., 2011a ; Da Silva et al., 2017 ).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
da Silva, D. L., Melo, C., & Hermes, C. J. L.
Affiliations
Universidade Federal do Paraná (BR)
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2017-01
Volume
111
Pages
1060-1068
ISSN
1359-4311 (ISSN-L)
OpenAlex
W2528061945
Cited by
58
References
26
Citations by year
2026: 5 · 2025: 5 · 2024: 5 · 2023: 2 · 2022: 9 · 2021: 4 · 2020: 6 · 2019: 9 · 2018: 8 · 2017: 4 · 2016: 1
FWCI
6.52
Type
journal article
Language
en
Open access
closed
Locations
Applied Thermal Engineering (publishedVersion)
Funders
  • POLO Labs (573581/2008-8)
  • Brazilian Government Agency CNPq
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
Keywords
thermal-hydraulic performance, frost density, cooling capacity, pressure drop, thawing, heat exchanger design, refrigeration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review