Cited by 18Icing and De-icing TechnologiesRefrigeration and Air Conditioning TechnologiesHeat Transfer and Optimization

Experimental study on the frosting characteristics of round tube in confined circular flow path at low temperature

Lai, Tianwei, Ding, Pei, Dong, Xiaojun, Zhang, Beile, Chen, Xiaozhuan, Hou, Yu·2020·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2020.115075

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • On a cylinder under parallel flow, the greatest frost thickness occurs in the centre region of the air flow path, and the lowest in the region close to the inlet of air flow.

    “The greatest frost thickness occurred in the centre region of the air flow path, and the lowest in the region close to the inlet of air flow.”
  • On a cylinder under parallel flow in a confined space, the combined effect of decreased air temperature and humidity ratio along air flow direction leads to the irregular frost thickness distribution.

    “It was the com­ bined effect of decreased air temperature and humidity ratio along air flow direction that led to the irregular frost thickness distribution.”
  • Hosseini et al. developed black-box frosting models based on intelligent methods, including multilayer perceptron trained by Bayesian Regulation and adaptive neuro fuzzy inference system, and the model can predict average frost thickness on different configurations such as vertical, horizontal, and parallel plates.

    “Hosseini et al. [129] also developed black-box frosting models based on intelligent methods, including multilayer perceptron trained by Bayesian Regulation and adaptive neuro fuzzy inference system. The model can be used to predict average frost thickness on different con­ figurations, such as vertical, horizontal, and parallel plates.”
  • On a cylinder under parallel flow in a confined space, decreased air temperature accelerates frost thickness growth, while decreased air moisture content impedes it.

    “The authors believed that the decreased air temperature accelerated the growth of frost thickness, while the decreased air moisture content impended it.”
  • On a cylinder under parallel flow, periodic melting and re-frosting phenomenon appears and its frequency increases with increasing cylinder surface temperature, air temperature, and air moisture content.

    “The experimental results showed that periodic melting and re-frosting phe­ nomenon appeared and its frequency was increased with an increase in cylinder surface temperature, air temperature, and air moisture content.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lai, T., Ding, P., Dong, X., Zhang, B., Chen, X., & Hou, Y.
Affiliations
  • State Key Laboratory of Multiphase Flow in Power Engineering (CN)
  • Henan Polytechnic University (CN)
Corresponding author
Hou, Yu
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2020-05
Volume
171
Pages
115075
ISSN
1359-4311 (ISSN-L)
OpenAlex
W3005564235
Cited by
18
References
9
Citations by year
2025: 3 · 2023: 2 · 2022: 8 · 2021: 4 · 2020: 1
FWCI
2.25
Type
journal article
Language
en
Open access
closed
Locations
Applied Thermal Engineering (publishedVersion)
Funders
  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
Keywords
low temperature, frost melting, frost thickness, frost density, heat transfer rate, relative humidity, air velocity, frost accumulation, dimensionless correlation, heat exchangers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›