Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects
Abstract
Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There have been multiple previous works that have delved into using dual-mode ECG and SCG sensing for cardiac time intervals measurements. [26-29]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
In the citing paper
“The increase in PEP and the decrease in LVET is well documented in prior literature [26,47] and is attributed to changes in preload, contractility, and afterload.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
New non-invasive index for combined systolic and diastolic ventricular function.
Tei, C. (1995) · PubMed · Cited by 688
Bedside technics for the evaluation of ventricular function in man
Weissler, A. M., Harris, W. S., & Schoenfeld, C. D. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90012-5 · Cited by 604
Martin, C. E., Shaver, J. A., Thompson, M. E., REDDY, P. S., & Leonard, J. J. (1971) · Circulation · doi:10.1161/01.cir.44.3.419 · Cited by 192
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · cited 2×
“This annotation was proposed by Crow and colleagues (Crow et al., 1994) as result of a direct comparison of SCG displacements with echocardiographic images, where ATC = atrial contraction; MC = closure of mitral valve; AO = opening of aortic valve; MA = point of maximal blood acceleration in the…”
Ballistocardiography — A method worth revisiting
Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091062 · Cited by 165
Castiglioni, P., Faini, A., Parati, G., & Rienzo, M. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353199 · Cited by 156
Self-citationSeismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149
Computerized heart sounds analysis
Debbal, S. M. E. A., & Bereksi-Reguig, F. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.09.006 · Cited by 137
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–163 of 163
Knowing Your Heart Condition Anytime
Wang, L., Wang, X., Zhang, D., Ma, X., Zhang, Y., Dai, H., Xu, C., Li, Z., & Gu, T. (2023) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3610871 · Cited by 10
Postural and longitudinal variability in seismocardiographic signals
Azad, M. K., Gamage, P. T., Dhar, R., Sandler, R. H., & Mansy, H. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acb30e · Cited by 10
Zia, J. S., Kimball, J. P., Rozell, C. J., & Inan, O. T. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3014040 · Cited by 10
Shandhi, M. M. H., Aras, M. A., Wynn, S., Fan, J., Heller, J. A., Etemadi, M., Klein, L., & Inan, O. T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176074 · Cited by 10
Drobczyk, M., Lübken, A., Strowik, C., Albrecht, U., Rust, J., Beringer, J., & Kulau, U. (2022) · IEEE Journal of Radio Frequency Identification · doi:10.1109/jrfid.2022.3166026 · Cited by 10
Transforming Seismocardiograms Into Electrocardiograms by Applying Convolutional Autoencoders
Haescher, M., Höpfner, F., Chodan, W., Kraft, D., Aehnelt, M., & Urban, B. (2020) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp40776.2020.9053130 · Cited by 10
Garssen, S. H., Kant, N., Vernooij, C. A., Mauritz, G.-J., Koning, M. V., Bosch, F. H., & Doggen, C. J. M. (2023) · Trials · doi:10.1186/s13063-023-07416-8 · Cited by 9
Estimating Fetal Gestational Age Using Cardiac Valve Intervals
Marzbanrad, F., Khandoker, A. H., Kimura, Y., Palaniswami, M. S., & Clifford, G. D. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.035-146 · Cited by 8
Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram
Mafi, M. (2016) · University Library - University of Saskatchewan (University of Saskatchewan) · Cited by 8
Mann, A. J., Rahman, M. M., Vanga, V., Gamage, P. T., & Taebi, A. (2024) · Journal of Medical Devices · doi:10.1115/1.4066368 · Cited by 7
Accuracy of the Instantaneous Breathing and Heart Rates Estimated by Smartphone Inertial Units
Cinotti, E., Centracchio, J., Parlato, S., Esposito, D., Fratini, A., Bifulco, P., & Andreozzi, E. (2025) · Sensors · doi:10.3390/s25041094 · Cited by 7
Effect of Respiratory Effort Levels on SCG Signals
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2019) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp46218.2019.8971092 · Cited by 7
Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace
Zia, J. S., Kimball, J. P., Hersek, S., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2980979 · Cited by 7
Biometric Recognition based on Heart-Induced Chest Vibrations
Maiorana, E., & Massaroni, C. (2021) · International Workshop on Biometrics and Forensics (IWBF) · doi:10.1109/iwbf50991.2021.9465086 · Cited by 7
Exploring the Impact of Sensor Location on Seismocardiography-Derived Cardiac Time Intervals
Mann, A. J., Gamage, P. T., Kakavand, B., & Taebi, A. (2023) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4063203 · Cited by 7
CardioID: Secure ECG-BCG Agnostic Interaction-Free Device Pairing
Zuo, S., Sigg, S., Nguyen, L. N., Beck, N., Jähne-Raden, N., & Wolf, M. C. (2022) · IEEE Access · doi:10.1109/access.2022.3226503 · Cited by 6
A Novel Seismocardiogram Mathematical Model for Simplified Adjustment of Adaptive Filter
Uskovas, G., Valinevičius, A., Žilys, M., Navikas, D., Frivaldský, M., Prauzek, M., Konecny, J., & Andriukaitis, D. (2022) · Electronics · doi:10.3390/electronics11152444 · Cited by 6
Analyzing SCG methodology for identification of ventricular depolarization events
Das, M., Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106940 · Cited by 5
Heartbeats Localization in Forcecardiography Signals Via Template Matching
Centracchio, J., & Muto, V. (2022) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb55594.2022.9991505 · Cited by 5
Inferring cardiovascular control from spontaneous variability
Porta, A., & Zebrowski, J. J. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.05.006 · Cited by 5
Fog-Enabled Multimodal Chest-Worn Device for Systolic Blood Pressure Monitoring
Salas, P., Mejia, J. M., & González-Landaeta, R. (2025) · IEEE Access · doi:10.1109/access.2025.3571829 · Cited by 4
Accurate ECG-Free Heartbeats Localization in Long-Lasting SCG Recordings
Parlato, S., Muto, V., & Bifulco, P. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-62520-6_23 · Cited by 4
Yu, S., Xie, A., Liu, Y., Guo, Y., & Wang, G. (2024) · Measurement · doi:10.1016/j.measurement.2024.115942 · Cited by 4
AI-based approach for heart failure readmission prediction using SCG, ECG, and GSR signals
Dhar, R., Hossen, M. R., Gamage, P. T., Sandler, R. H., RAVAL, N. Y., Mentz, R. J., & Mansy, H. A. (2025) · Physiological Measurement · doi:10.1088/1361-6579/ae178c · Cited by 4
Yu, S., Song, Q., & Liu, S. (2020) · IEEE Access · doi:10.1109/access.2020.3013380 · Cited by 4
A soft sensor based on FBG technology for heart rate monitoring in archery
Presti, D. L., Romano, C., Leitão, C., Massaroni, C., Formica, D., & Schena, E. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856545 · Cited by 5
Seismocardiography-based detection of cardiac quiescence for cardiac computed tomography angiography
Wick, C. A., McClellan, J. H., Inan, O. T., & Tridandapani, S. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945016 · Cited by 4
Estimation of Beat-to-Beat Interval and Systolic Time Intervals Using Phono- and Seismocardiograms
Ahmaniemi, T., Rajala, S., & Lindholm, H. J. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856931 · Cited by 4
Centracchio, J., Parlato, S., Schmidt, S. E., Bifulco, P., Esposito, D., & Andreozzi, E. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01657-4 · Cited by 3
Zienkiewicz, A., Korhonen, V. O., Kiviniemi, V. V., & Myllylä, T. (2024) · Biosensors · doi:10.3390/bios14120621 · Cited by 3
Sieciński, S., & Kostka, P. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-91211-0_30 · Cited by 3
Albrecht, U., Mielitz, A., Rahman, K. M. A., & Kulau, U. (2024) · JMIR Research Protocols · doi:10.2196/63306 · Cited by 3
Analyzing Heart Rate Estimation from Vibrational Cardiography with Different Orientations
Aboulezz, E., Skoric, J., D’Mello, Y., Hakim, S., Clairmonte, N., Lortie, M. A., & Plant, D. V. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175255 · Cited by 3
Rienzo, M. D., & Piccirillo, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00017-6 · Cited by 3
Balali, P., Luchitskaya, E. S., Hossein, A., Abdessater, E., Faoro, V., Debeir, O., Tank, J., Caiani, E. G., van de Borne, P., Migeotte, P., et al. (2025) · npj Microgravity · doi:10.1038/s41526-025-00522-8 · Cited by 2
Generating Alerts from Breathing Pattern Outliers
Benmussa, C., Cauchard, J. R., & Zohar Yakhini, B. (2022) · Sensors · doi:10.3390/s22166306 · Cited by 2
Making Noise - Improving Seismocardiography Based Heart Analysis With Denoising Autoencoders
Burian, J., Toedtmann, H., Haescher, M., Aehnelt, M., & Kuijper, A. (2023) · International Workshop on Sensor-based Activity Recognition and Interaction (iWOAR) · doi:10.1145/3615834.3615847 · Cited by 2
Skoric, J., D’Mello, Y., & Plant, D. V. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3485535 · Cited by 2
Carter, A., Humphreys, L. J., Beswick, A., Kesterton, S., Bugg, A., & Platts, K. (2025) · BMC Public Health · doi:10.1186/s12889-025-21480-6 · Cited by 4
Accurate annotation of SeismoCardioGram exploiting multi-dimensional accelerometry
Mora, N., Cocconcelli, F., Matrella, G., & Ciampolini, P. (2018) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec.2018.8674235 · Cited by 2
Tokmak, F., & Semiz, B. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3194594 · Cited by 2
Thakkar, H. K., & Sahoo, P. K. (2022) · Springer eBooks · doi:10.1007/978-3-031-18034-7_10 · Cited by 1
Chen, C., Lin, W., & Lee, M. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3322675 · Cited by 1
Lin, D. J., Nikbakht, M. R., Lewis, R., Medda, A., & Inan, O. T. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10331421 · Cited by 1
Mace, M. I., Lala-Trindade, A., Fendler, T. J., & Sauer, A. J. (2025) · Heart Failure Reviews · doi:10.1007/s10741-025-10513-2 · Cited by 1
Quantifying changes in triaxial seismocardiography variability due to sub-optimal volume status
Cestero, G. I., Bouzid, Z., Nawar, A., Yaldiz, C. O., Tangolar, D., Wu, Z. J., Hahn, J., & Inan, O. T. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1823345 · Cited by 1
Canales, P. S., Mejia, J. M., & González-Landaeta, R. (2023) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-46933-6_33 · Cited by 1
An Adaptive SCG-ECG Multimodal Gating Framework for Cardiac CTA
Ganesh, S., Abozeed, M., Aziz, U., Tridandapani, S., & Bhatti, P. T. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01289-2 · Cited by 1
Suppression of Artifacts from Seismocardiogram Signal using Two-Stage Kalman Filtering Model
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · International Conference on Signal Processing and Communications (SPCOM) · doi:10.1109/spcom.2018.8724412 · Cited by 1
High-Resolution Synchronous Digital Ballistocardiography Setup
Jähne-Raden, N., Kulau, U., Gütschleg, H., Clausen, T., Jura, T., Sigg, S., & Wolf, L. C. (2019) · Aaltodoc (Aalto University) · doi:10.23919/cinc49843.2019.9005482 · Cited by 1
Non Contact Methods of Heart Rate Variability Measuring and Analysis
Štork, M., & Houzar, J. (2020) · International Conference on Applied Electronics · doi:10.23919/ae49394.2020.9232744 · Cited by 1
Seismocardiography: Interpretation and Clinical Application
Sørensen, K. (2021) · doi:10.54337/aau451017905 · Cited by 1
Luu, L. (2017) · HARVEST (University of Saskatchewan)
Kushagra, A., Dasgupta, U., Roychowdhury, S., Samanta, S., & Srivastava, S. (2022) · AIP Advances · doi:10.1063/5.0076791
Wearable sensors for cardiorespiratory monitoring: solutions and applications
Massaroni, C., Presti, D. L., & Schena, E. (2024) · International Workshop on Biomedical Applications, Technologies and Sensors (BATS) · doi:10.1109/q-bats63267.2024.10873878
Garssen, S. H., Kant, N., Vernooij, C. A., Mauritz, G.-J., Koning, M. V., Bosch, F. H., & Doggen, C. J. M. (2023) · Figshare · doi:10.6084/m9.figshare.23519957
A Flexible Triboelectric-Based Sensor for Seismocardiography Monitoring
Wang, C., He, Y., Peng, H., Luo, H., & Wang, X. (2026) · Biosensors · doi:10.3390/bios16050260
Teckchandani, T. A., Neary, J. P., Norrie, H. J., Flegel, K. P., Maguire, K. Q., Krätzig, G. P., & Carleton, R. N. (2026) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/cjpp-2026-0116
Ostrysz, M. (2026) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2026.102290
Cardiac signal monitoring using femtosecond laser inscribed FBGs in CYTOP optical fiber
Hu, Y. Y., Ioannou, A., Yu, C., & Kalli, K. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118622
Metadata
- Authors
- Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F.
- Affiliations
- Don Carlo Gnocchi Foundation (IT)
- University of Milan (IT)
- University of Milano-Bicocca (IT)
- Venue
- Autonomic Neuroscience
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 178
- Issue
- 1-2
- Pages
- 50-59
- ISSN
- 1566-0702 (ISSN-L)
- OpenAlex
- W2007729863
- Cited by
- 163
- References
- 37
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 12 · 2023: 19 · 2022: 19 · 2021: 11 · 2020: 20 · 2019: 13 · 2018: 19 · 2017: 10 · 2016: 11 · 2015: 7 · 2014: 8 · 2013: 1
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Autonomic Neuroscience (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- IrInSubria (University of Insubria) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiography, wearable cardiac monitoring, smart garments, cardiac contractility, pre-ejection period, left ventricular ejection time, aortic valve opening, heart rate variability, daily activity monitoring
- MeSH terms
- Acceleration, Adult, Ambulances, Ballistocardiography, Female, Heart Rate, Humans, Male, Myocardial Contraction, Plethysmography, Posture, Signal Processing, Computer-Assisted, Electrocardiography, Ambulatory, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review