The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects
Abstract
Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There have been multiple previous works that have delved into using dual-mode ECG and SCG sensing for cardiac time intervals measurements. [26-29]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
In the citing paper
“The increase in PEP and the decrease in LVET is well documented in prior literature [26,47] and is attributed to changes in preload, contractility, and afterload.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
New non-invasive index for combined systolic and diastolic ventricular function.
Tei, C. (1995) · PubMed · Cited by 688
Bedside technics for the evaluation of ventricular function in man
Weissler, A. M., Harris, W. S., & Schoenfeld, C. D. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90012-5 · Cited by 604
Martin, C. E., Shaver, J. A., Thompson, M. E., REDDY, P. S., & Leonard, J. J. (1971) · Circulation · doi:10.1161/01.cir.44.3.419 · Cited by 192
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · cited 2×
“This annotation was proposed by Crow and colleagues (Crow et al., 1994) as result of a direct comparison of SCG displacements with echocardiographic images, where ATC = atrial contraction; MC = closure of mitral valve; AO = opening of aortic valve; MA = point of maximal blood acceleration in the…”
Ballistocardiography — A method worth revisiting
Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091062 · Cited by 165
Castiglioni, P., Faini, A., Parati, G., & Rienzo, M. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353199 · Cited by 156
Self-citationSeismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149
Computerized heart sounds analysis
Debbal, S. M. E. A., & Bereksi-Reguig, F. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.09.006 · Cited by 137
Cited by
Sorted by citations
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 278
Contactless seismocardiography via deep learning radars
Ha, U., Assana, S., & Adib, F. (2020) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3372224.3419982 · Cited by 203
Tadi, M. J., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J. K. E., Pänkäälä, M., & Koivisto, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-07248-y · Cited by 179
Metadata
- Authors
- Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F.
- Affiliations
- Don Carlo Gnocchi Foundation (IT)
- University of Milan (IT)
- University of Milano-Bicocca (IT)
- Venue
- Autonomic Neuroscience
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 178
- Issue
- 1-2
- Pages
- 50-59
- ISSN
- 1566-0702 (ISSN-L)
- OpenAlex
- W2007729863
- Cited by
- 163
- References
- 37
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 12 · 2023: 19 · 2022: 19 · 2021: 11 · 2020: 20 · 2019: 13 · 2018: 19 · 2017: 10 · 2016: 11 · 2015: 7 · 2014: 8 · 2013: 1
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Autonomic Neuroscience (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- IrInSubria (University of Insubria) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiography, wearable cardiac monitoring, smart garments, cardiac contractility, pre-ejection period, left ventricular ejection time, aortic valve opening, heart rate variability, daily activity monitoring
- MeSH terms
- Acceleration, Adult, Ambulances, Ballistocardiography, Female, Heart Rate, Humans, Male, Myocardial Contraction, Plethysmography, Posture, Signal Processing, Computer-Assisted, Electrocardiography, Ambulatory, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review