The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects
Abstract
Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There have been multiple previous works that have delved into using dual-mode ECG and SCG sensing for cardiac time intervals measurements. [26-29]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
In the citing paper
“The increase in PEP and the decrease in LVET is well documented in prior literature [26,47] and is attributed to changes in preload, contractility, and afterload.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
New non-invasive index for combined systolic and diastolic ventricular function.
Tei, C. (1995) · PubMed · Cited by 688
Bedside technics for the evaluation of ventricular function in man
Weissler, A. M., Harris, W. S., & Schoenfeld, C. D. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90012-5 · Cited by 604
Martin, C. E., Shaver, J. A., Thompson, M. E., REDDY, P. S., & Leonard, J. J. (1971) · Circulation · doi:10.1161/01.cir.44.3.419 · Cited by 192
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · cited 2×
“This annotation was proposed by Crow and colleagues (Crow et al., 1994) as result of a direct comparison of SCG displacements with echocardiographic images, where ATC = atrial contraction; MC = closure of mitral valve; AO = opening of aortic valve; MA = point of maximal blood acceleration in the…”
Ballistocardiography — A method worth revisiting
Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091062 · Cited by 165
Castiglioni, P., Faini, A., Parati, G., & Rienzo, M. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353199 · Cited by 156
Self-citationSeismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149
Computerized heart sounds analysis
Debbal, S. M. E. A., & Bereksi-Reguig, F. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.09.006 · Cited by 137
Cited by
Sorted by citations
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 278
Contactless seismocardiography via deep learning radars
Ha, U., Assana, S., & Adib, F. (2020) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3372224.3419982 · Cited by 203
Tadi, M. J., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J. K. E., Pänkäälä, M., & Koivisto, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-07248-y · Cited by 179
Li, K. H. C., White, F. A., Tipoe, T., Liu, T., Wong, M. C. S., Jesuthasan, A., Baranchuk, A. M., Tse, G., & Yan, B. P. (2018) · JMIR mhealth and uhealth · doi:10.2196/11606 · Cited by 172
Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies
Vitazkova, D., Foltan, E., Kosnacova, H., Micjan, M., Donoval, M., Kuzma, A., Kopáni, M., & Vavrinský, E. (2024) · Biosensors · doi:10.3390/bios14020090 · Cited by 168
Definition of Fiducial Points in the Normal Seismocardiogram
Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-33675-6 · Cited by 111
Heart monitoring systems—A review
Jain, P. K., & Tiwari, A. K. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.08.014 · Cited by 104
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms
Tadi, M. J., Lehtonen, E., Hurnanen, T., Koskinen, J., Eriksson, J., Pänkäälä, M., Teräs, M., & Koivisto, T. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/11/1885 · Cited by 102
Flexible sensors and machine learning for heart monitoring
Kwon, S. H., & Dong, L. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107632 · Cited by 99
Etemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95
“Recently, several researchers have developed wearable systems for measuring SCG signals during normal activities of daily living using micromachined (MEMS) accelerometers, including a wearable vest for SCG measurement in the field and during sleep [10], [11], a flexible patch with SCG and electrocardiogram (ECG) measu…”
Surface Chest Motion Decomposition for Cardiovascular Monitoring
Shafiq, G., & Veluvolu, K. C. (2014) · Scientific Reports · doi:10.1038/srep05093 · Cited by 92
A multi-point heart rate monitoring using a soft wearable system based on fiber optic technology
Presti, D. L., Santucci, F., Massaroni, C., Formica, D., Setola, R., & Schena, E. (2021) · Scientific Reports · doi:10.1038/s41598-021-00574-2 · Cited by 87
Barvik, D., Černý, M., Penhaker, M., & Noury, N. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3109643 · Cited by 85
Khosrow-Khavar, F., Tavakolian, K., Blaber, A. P., & Menon, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616382 · Cited by 82
Dehkordi, P., Khosrow-Khavar, F., Rienzo, M. D., Inan, O. T., Schmidt, S. E., Blaber, A. P., Sørensen, K., Struijk, J. J., Zakeri, V., Lombardi, P., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01057 · Cited by 82
A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health
Sahoo, P., Thakkar, H., & Lee, M.-Y. (2017) · Sensors · doi:10.3390/s17040711 · Cited by 81
Klum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75
An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications
Galli, A., Montree, R. J. H., Que, S., Peri, E., & Vullings, R. (2022) · Sensors · doi:10.3390/s22114035 · Cited by 87
Wang, L., Huang, K., Sun, K., Wang, W., Tian, C., Xie, L., & Gu, Q. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3264950 · Cited by 77
Sahoo, P. K., Thakkar, H. K., Lin, W., Chang, P., & Lee, M. (2018) · Sensors · doi:10.3390/s18020379 · Cited by 76
Shandhi, M. M. H., Semiz, B., Hersek, S., Goller, N., Ayazi, F., & Inan, O. T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2895775 · Cited by 74
Wiens, A. D., Etemadi, M., Roy, S., Klein, L., & Inan, O. T. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2359937 · Cited by 69
Systolic Time Intervals and New Measurement Methods
Tavakolian, K. (2016) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-016-0262-1 · Cited by 69
Automatic Identification of Systolic Time Intervals in Seismocardiogram
Shafiq, G., Tatinati, S., Ang, W. T., & Veluvolu, K. C. (2016) · Scientific Reports · doi:10.1038/srep37524 · Cited by 69
Automatic Detection of Aortic Valve Opening Using Seismocardiography in Healthy Individuals
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2829608 · Cited by 67
Seismocardiography: Toward heart rate variability (HRV) estimation
Tadi, M. J., Lehtonen, E., Koivisto, T., Pänkäälä, M., Paasio, A., & Teräs, M. (2015) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2015.7145210 · Cited by 63
Skin-interfaced wireless biosensors for perinatal and paediatric health
Kim, J., Yoo, S., Liu, C. Y., Kwak, S. S., Walter, J. R., Xu, S., & Rogers, J. A. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00090-0 · Cited by 64
Chest-Worn Inertial Sensors: A Survey of Applications and Methods
Rahmani, M. H., Berkvens, R., & Weyn, M. (2021) · Sensors · doi:10.3390/s21082875 · Cited by 56
Balali, P., Rabineau, J., Hossein, A., Tordeur, C., Debeir, O., & van de Borne, P. (2022) · Sensors · doi:10.3390/s22239565 · Cited by 49
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
Zia, J., Kimball, J., Hersek, S., Shandhi, M. M. H., Semiz, B., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931348 · Cited by 48
“A major limitation of SCG for outpatient continuous monitoring is its sensitivity to noise due to motion artifacts [6].”
BackgroundJacobs, F. E. N. B., Scheerhoorn, J., Mestrom, E. H. J., van der Stam, J. A., Bouwman, R. A., & Nienhuijs, S. W. (2021) · PLoS ONE · doi:10.1371/journal.pone.0247903 · Cited by 45
Rienzo, M. D., Rizzo, F., Isilay, Z. M., & Lombardi, P. (2020) · Sensors · doi:10.3390/s20030680 · Cited by 44
Self-citationECG-Free Heartbeat Detection in Seismocardiography Signals via Template Matching
Centracchio, J., Parlato, S. J., Esposito, D., Bifulco, P., & Andreozzi, E. (2023) · Sensors · doi:10.3390/s23104684 · Cited by 44
Lee, H., Lee, H., & Whang, M. (2018) · Sensors · doi:10.3390/s18010238 · Cited by 42
Bhattacharya, S., Nikbakht, M., Alden, A., Tan, P., Wang, J., Alhalimi, T. A., Kim, S., Wang, P., Tanaka, H., Tandon, A., et al. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201284 · Cited by 42
An Independent Component Analysis Approach to Motion Noise Cancelation of Cardio-Mechanical Signals
Yang, C., & Tavassolian, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2856700 · Cited by 41
Lin, W., Ke, H.-L., Chou, W.-C., Chang, P., Tsai, T.-H., & Lee, M. (2018) · Sensors · doi:10.3390/s18103538 · Cited by 40
Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals
Lin, D. J., Kimball, J. P., Zia, J. S., Ganti, V. G., & Inan, O. T. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3090376 · Cited by 39
Rienzo, M. D., Vaini, E., & Lombardi, P. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.02.034 · Cited by 38
Self-citationRienzo, M. D., Vaini, E., & Lombardi, P. (2017) · Scientific Reports · doi:10.1038/s41598-017-15829-0 · Cited by 37
Self-citationHeart Sound Extraction From Sternal Seismocardiographic Signal
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · IEEE Signal Processing Letters · doi:10.1109/lsp.2018.2801341 · Cited by 37
Romano, C., Formica, D., Schena, E., & Massaroni, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3245415 · Cited by 34
Smartphone accelerometers for the detection of heart rate
Landreani, F., & Caiani, E. G. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1407647 · Cited by 34
A Novel Method for Aortic Valve Opening Phase Detection Using SCG Signal
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2944235 · Cited by 34
Accuracy of vital parameters measured by a wearable patch following major abdominal cancer surgery
van der Stam, J. A., Mestrom, E. H. J., Scheerhoorn, J., Jacobs, F. E. N. B., de Hingh, I. H. J. T., van Riel, N. A. W., Boer, A., Scharnhorst, V., Nienhuijs, S. W., & Bouwman, R. A. (2021) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2021.10.034 · Cited by 36
Smart Sleep Monitoring System via Passively Sensing Human Vibration Signals
Li, F., Valero, M., Clemente, J. M., Tse, Z. T. H., & Song, W. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3013435 · Cited by 33
Mohamed, R., & Youssef, M. A. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3132028 · Cited by 33
Automatic annotation of peaks in seismocardiogram for systolic time intervals
Shafiq, G., Tatinati, S., & Veluvolu, K. C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591280 · Cited by 31
Hersek, S., Semiz, B., Shandhi, M. M. H., Orlandic, L., & Inan, O. T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931872 · Cited by 30
A Novel System Identification Technique for Improved Wearable Hemodynamics Assessment
Wiens, A. D., & Inan, O. T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2387354 · Cited by 29
Non-contact heart vibration measurement using computer vision-based seismocardiography
Rahman, M. M., Cook, J., & Taebi, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-38607-7 · Cited by 28
Fully Automated Annotation of Seismocardiogram for Noninvasive Vital Sign Measurements
Mora, N., Cocconcelli, F., Matrella, G., & Ciampolini, P. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2908511 · Cited by 27
Multimodal chest surface motion data for respiratory and cardiovascular monitoring applications
Shafiq, G., & Veluvolu, K. C. (2017) · Scientific Data · doi:10.1038/sdata.2017.52 · Cited by 28
Parlato, S. J., Centracchio, J., Esposito, D., Bifulco, P., & Andreozzi, E. (2023) · Sensors · doi:10.3390/s23198114 · Cited by 27
Performance analysis of seismocardiography for heart sound signal recording in noisy scenarios
Jain, P. K., Tiwari, A. K., & Chourasia, V. S. (2016) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2016.1139203 · Cited by 25
Yao, J., Tridandapani, S., Auffermann, W. F., Wick, C. A., & Bhatti, P. T. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2869141 · Cited by 24
Khamis, A., Chou, C. T., Kusý, B., & Hu, W. S. (2018) · EAI International Conference on Mobile and Ubiquitous Systems: Computing, Networking and Services (MobiQuitous) · doi:10.1145/3286978.3287003 · Cited by 26
Cuffless and Continuous Blood Pressure Monitoring Using a Single Chest-Worn Device
Park, J., Yang, S.-M., Sohn, J., Lee, J., Lee, S., Ku, Y., & Kim, H. C. (2019) · IEEE Access · doi:10.1109/access.2019.2942184 · Cited by 25
Hossein, A., Rabineau, J., Gorlier, D., Rio, J. I. J. D., van de Borne, P., Migeotte, P., & Nonclercq, A. (2021) · Sensors · doi:10.3390/s21030815 · Cited by 24
Heartbeat Detection in Gyrocardiography Signals without Concurrent ECG Tracings
Parlato, S. J., Centracchio, J., Esposito, D., Bifulco, P., & Andreozzi, E. (2023) · Sensors · doi:10.3390/s23136200 · Cited by 23
Isilay, Z. M., Racca, V., Pezzano, A., Tavanelli, M., & Rienzo, M. D. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.825918 · Cited by 22
Hoffmann, B., Dehkordi, P., Khosrow-Khavar, F., Goswami, N., Blaber, A. P., & Tavakolian, K. (2022) · npj Microgravity · doi:10.1038/s41526-022-00206-7 · Cited by 22
Yao, J., Tridandapani, S., Wick, C. A., & Bhatti, P. T. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2708100 · Cited by 22
Autocorrelated Differential Algorithm for Real-Time Seismocardiography Analysis
D’Mello, Y., Skoric, J., Xu, S., Akhras, M., Roche, P. J. R., Lortie, M. A., Gagnon, S., & Plant, D. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2903449 · Cited by 22
Electrocardiogram Devices for Home Use: Technological and Clinical Scoping Review
Zepeda-Echavarria, A., van de Leur, R. R., van Sleuwen, M., Hassink, R. J., Wildbergh, T. X., Doevendans, P. A., Jaspers, J., & van Es, R. (2023) · JMIR Cardio · doi:10.2196/44003 · Cited by 24
Simple Heart Rate Monitoring System with a MEMS Gyroscope for Sleep Studies
Hernandez, J. E., & Cretu, E. (2018) · IEEE Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON) · doi:10.1109/iemcon.2018.8614753 · Cited by 21
Kimball, J. P., Inan, O. T., Convertino, V. A., Cardin, S., & Sawka, M. N. (2022) · Sensors · doi:10.3390/s22020442 · Cited by 19
Respiratory Modulation of Sternal Motion in the Context of Seismocardiography
Skoric, J., D’Mello, Y., Aboulezz, E., Hakim, S., Clairmonte, N., Lortie, M. A., & Plant, D. V. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3173205 · Cited by 18
Changes in Forcecardiography Heartbeat Morphology Induced by Cardio-Respiratory Interactions
Centracchio, J., Esposito, D., Gargiulo, G. D., & Andreozzi, E. (2022) · Sensors · doi:10.3390/s22239339 · Cited by 18
Seismocardiography-Based Detection of Cardiac Quiescence
Wick, C. A., Inan, O. T., McClellan, J. H., & Tridandapani, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2411155 · Cited by 18
A textile-based wearable system for the prolonged assessment of cardiac mechanics in daily life
Rienzo, M. D., Vaini, E., Castiglioni, P., Lombardi, P., Meriggi, P., & Rizzo, F. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945213 · Cited by 18
Self-citationA Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography
Skoric, J., D’Mello, Y., & Plant, D. V. (2024) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2024.3368291 · Cited by 20
High-Accuracy, Unsupervised Annotation of Seismocardiogram Traces for Heart Rate Monitoring
Cocconcelli, F., Mora, N., Matrella, G., & Ciampolini, P. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2967135 · Cited by 17
Identification of Human Breathing-States Using Cardiac-Vibrational Signal for m-Health Applications
Choudhary, T., Sharma, L. N., Bhuyan, M. K., & Bora, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3025384 · Cited by 16
Delineation and Analysis of Seismocardiographic Systole and Diastole Profiles
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3007295 · Cited by 16
A Differential BCG Sensor System for Long Term Health Monitoring Experiment on the ISS
Kulau, U., Rust, J., Szafranski, D., Drobczyk, M., & Albrecht, U. (2022) · International Conference on Distributed Computing in Smart Systems and the Internet of Things (DCOSS-IoT) · doi:10.1109/dcoss54816.2022.00028 · Cited by 16
Heart Rate Estimated from Body Movements at Six Degrees of Freedom by Convolutional Neural Networks
Lee, H., & Whang, M. (2018) · Sensors · doi:10.3390/s18051392 · Cited by 16
Ebrahimkhani, M., Johnson, E., Sodhi, A., Robinson, J. D., Rigsby, C. K., Allen, B. D., & Markl, M. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03342-7 · Cited by 15
Javaid, A. Q., Fesmire, N. F., Weitnauer, M. A., & Inan, O. T. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299377 · Cited by 15
Motion noise cancellation in seismocardiographic monitoring of moving subjects
Yang, C., & Tavassolian, N. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348361 · Cited by 15
Motion noise cancellation in seismocardiogram of ambulant subjects with dual sensors
Yang, C., & Tavassolian, N. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592066 · Cited by 15
Assessment of Fetal Development Using Cardiac Valve Intervals
Marzbanrad, F., Khandoker, A. H., Kimura, Y., Palaniswami, M. S., & Clifford, G. D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00313 · Cited by 15
Orthogonal subspace projection based framework to extract heart cycles from SCG signal
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.01.005 · Cited by 15
A novel method for suppression of motion artifacts from the seismocardiogram signal
Jain, P. K., & Tiwari, A. K. (2016) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2016.7868504 · Cited by 15
Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI
Johnson, E. M. I., Heller, J. A., Garcia Vicente, F., Sarnari, R., Gordon, D., McCarthy, P. M., Barker, A. J., Etemadi, M., & Markl, M. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02491-3 · Cited by 14
An Approach of Heartbeat Segmentation in Seismocardiogram by Matched-Filtering
Li, Y., Tang, X., & Xu, Z. F. (2015) · International Conference on Intelligent Human-Machine Systems and Cybernetics · doi:10.1109/ihmsc.2015.157 · Cited by 14
Robust Detection of AO and IM Points in the Seismocardiogram Using CWT
Rivero-Pouymiró, I., Valdés, E., & Valdés-Pérez, F. E. (2016) · IEEE Latin America Transactions · doi:10.1109/tla.2016.7795816 · Cited by 14
A Precise, Parallel and Scalable Measurement System for Ballistocardiographic Research
Clausen, T., Jura, T., Jähne-Raden, N., Wolf, M. C., Wolf, L. C., & Kulau, U. (2020) · Smart Health · doi:10.1016/j.smhl.2020.100169 · Cited by 14
Drobczyk, M., Lübken, A., Strowik, C., Kulau, U., Rust, J., Beringer, J., & Albrecht, U. (2021) · IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE) · doi:10.1109/wisee50203.2021.9613824 · Cited by 14
Accurate Blood Pressure Measurement Using Smartphone's Built-in Accelerometer
Wang, L., Wang, X., Zhang, Y., Ma, X., Dai, H., Zhang, Y., Li, Z., & Gu, T. (2024) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3659599 · Cited by 13
Hossein, A., Rabineau, J., Gorlier, D., Pinky, F., van de Borne, P., Nonclercq, A., & Migeotte, P. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00837-5 · Cited by 13
Systolic time intervals assessed from analysis of the carotid pressure waveform
Salvi, P., Grillo, A., Tan, I., Simon, G., Salvi, L., Gao, L., Rovina, M., Butlin, M., Yang, Y., Meneghin, E., et al. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad51b · Cited by 13
Self-citationStandalone Heartbeat Extraction in SCG Signal Using Variational Mode Decomposition
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · International Conference on Wireless Communications, Signal Processing and Networking (WiSPNET) · doi:10.1109/wispnet.2018.8538723 · Cited by 13
Wang, J., Foster, M., Bozkurt, A. Y., & Roberts, D. L. (2022) · International Conference on Animal-Computer Interaction (ACI) · doi:10.1145/3565995.3566037 · Cited by 12
Chen, C., Lin, W., & Lee, M. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9283120 · Cited by 12
Parlato, S., Centracchio, J., Esposito, D., Bifulco, P., & Andreozzi, E. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01531-3 · Cited by 11
Wearable seismocardiography for the beat-to-beat assessment of cardiac intervals during sleep
Rienzo, M. D., Vaini, E., Castiglioni, P., Lombardi, P., Parati, G., Lombardi, C., Meriggi, P., & Rizzo, F. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945018 · Cited by 11
Self-citationDetermining Heart Rate Beat-to-Beat from Smartphone Seismocardiograms: Preliminary Studies
Sieciński, S., & Kostka, P. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-70063-2_15 · Cited by 11
Metadata
- Authors
- Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F.
- Affiliations
- Don Carlo Gnocchi Foundation (IT)
- University of Milan (IT)
- University of Milano-Bicocca (IT)
- Venue
- Autonomic Neuroscience
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 178
- Issue
- 1-2
- Pages
- 50-59
- ISSN
- 1566-0702 (ISSN-L)
- OpenAlex
- W2007729863
- Cited by
- 163
- References
- 37
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 12 · 2023: 19 · 2022: 19 · 2021: 11 · 2020: 20 · 2019: 13 · 2018: 19 · 2017: 10 · 2016: 11 · 2015: 7 · 2014: 8 · 2013: 1
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Autonomic Neuroscience (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- IrInSubria (University of Insubria) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiography, wearable cardiac monitoring, smart garments, cardiac contractility, pre-ejection period, left ventricular ejection time, aortic valve opening, heart rate variability, daily activity monitoring
- MeSH terms
- Acceleration, Adult, Ambulances, Ballistocardiography, Female, Heart Rate, Humans, Male, Myocardial Contraction, Plethysmography, Posture, Signal Processing, Computer-Assisted, Electrocardiography, Ambulatory, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review