The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Lipid imaging with time-of-flight secondary ion mass spectrometry (ToF-SIMS)
Open accessAbstract
Fundamental advances in secondary ion mass spectrometry (SIMS) now allow for the examination and characterization of lipids directly from biological materials. The successful application of SIMS-based imaging in the investigation of lipids directly from tissue and cells are demonstrated. Common complications and technical pitfalls are discussed. In this review, we examine the use of cluster ion sources and cryogenically compatible sample handling for improved ion yields and to expand the application potential of SIMS. Methodological improvements, including pre-treating the sample to improve ion yields and protocol development for 3-dimensional analyses (i.e. molecular depth profiling), are also included in this discussion. New high performance SIMS instruments showcasing the most advanced instrumental developments, including tandem MS capabilities and continuous ion beam compatibility, are described and the future direction for SIMS in lipid imaging is evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basal Lipid Peroxidation in Substantia Nigra Is Increased in Parkinson's Disease
Dexter, D. T., Carter, C. J., Wells, F. R., Javoy‐Agid, F., Agid, Y., Lees, A., Jenner, P., & Marsden, C. D. (1989) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1989.tb09133.x · Cited by 1,397
Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry
Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. N. (1981) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39810000325 · Cited by 1,106
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Wiseman, J. M., Ifa, D. R., Song, Q., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602449 · Cited by 626
Sublimation as a method of matrix application for mass spectrometric imaging
Hankin, J. A., Barkley, R. M., & Murphy, R. C. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.06.010 · Cited by 598
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Reyzer, M. L., Hsieh, Y., Ng, K., Korfmacher, W. A., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.525 · Cited by 371
Mass Spectrometric Imaging of Highly Curved Membranes During Tetrahymena Mating
Ostrowski, S. G., Van Bell, C. T., Winograd, N., & Ewing, A. G. (2004) · Science · doi:10.1126/science.1099791 · Cited by 330
Self-citationAn update of MALDI-TOF mass spectrometry in lipid research
Fuchs, B., Süß, R., & Schiller, J. (2010) · Progress in Lipid Research · doi:10.1016/j.plipres.2010.07.001 · Cited by 324
Mass Spectrometric Imaging of Lipids in Brain Tissue
Sjövall, P., Lausmaa, J., & Johansson, B. (2004) · Analytical Chemistry · doi:10.1021/ac049389p · Cited by 313
Advances in Imaging Secondary Ion Mass Spectrometry for Biological Samples
Boxer, S. G., Kraft, M. L., & Weber, P. K. (2009) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133634 · Cited by 308
Fletcher, J. S., Lockyer, N. P., Vaidyanathan, S., & Vickerman, J. C. (2007) · Analytical Chemistry · doi:10.1021/ac061370u · Cited by 302
Imaging of lipid species by MALDI mass spectrometry
Murphy, R. C., Hankin, J. A., & Barkley, R. M. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800051-jlr200 · Cited by 299
Cluster secondary ion mass spectrometry of polymers and related materials
Mahoney, C. M. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20233 · Cited by 293
Cluster primary ion bombardment of organic materials
Kollmer, F. (2004) · Applied Surface Science · doi:10.1016/j.apsusc.2004.03.101 · Cited by 289
A New Dynamic in Mass Spectral Imaging of Single Biological Cells
Fletcher, J. S., Rabbani, S., Henderson, A., Blenkinsopp, P., Thompson, S. P., Lockyer, N. P., & Vickerman, J. C. (2008) · Analytical Chemistry · doi:10.1021/ac8015278 · Cited by 289
MALDI-MS imaging of features smaller than the size of the laser beam
Jurchen, J. C., Rubakhin, S. S., & Sweedler, J. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.006 · Cited by 285
Gold-Enhanced Biomolecular Surface Imaging of Cells and Tissue by SIMS and MALDI Mass Spectrometry
Altelaar, A. F. M., Klinkert, I., Jalink, K., de Lange, R. P. J., Adan, R. A. H., Heeren, R. M. A., & Piersma, S. R. (2006) · Analytical Chemistry · doi:10.1021/ac0513111 · Cited by 278
Phase Separation of Lipid Membranes Analyzed with High-Resolution Secondary Ion Mass Spectrometry
Kraft, M. L., Weber, P. K., Longo, M. L., Hutcheon, I. D., & Boxer, S. G. (2006) · Science · doi:10.1126/science.1130279 · Cited by 272
Mass spectrometry: from proteomics to metabolomics and lipidomics
Griffiths, W. J., & Wang, Y. (2009) · Chemical Society Reviews · doi:10.1039/b618553n · Cited by 271
Ifa, D. R., Wiseman, J. M., Song, Q., & Cooks, R. G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.08.003 · Cited by 261
Atomic and Molecular Imaging at the Single-Cell Level with TOF-SIMS
Colliver, T. L., Brummel, C. L., Pacholski, M. L., Swanek, F. D., Ewing, A. G., & Winograd, N. (1997) · Analytical Chemistry · doi:10.1021/ac9701748 · Cited by 260
Self-citationCluster primary ion bombardment of organic materials
KOLLMER, F. (2004) · Applied Surface Science · doi:10.1016/s0169-4332(04)00339-3 · Cited by 227
Molecular imaging and depth profiling by mass spectrometry—SIMS, MALDI or DESI?
Vickerman, J. C. (2011) · The Analyst · doi:10.1039/c1an00008j · Cited by 211
Wolstenholme, R., Bradshaw, R., Clench, M. R., & Francese, S. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4218 · Cited by 187
Ambient molecular imaging by desorption electrospray ionization mass spectrometry
Wiseman, J. M., Ifa, D. R., Venter, A., & Cooks, R. G. (2008) · Nature Protocols · doi:10.1038/nprot.2008.11 · Cited by 171
In Situ Lipidomic Analysis of Nonalcoholic Fatty Liver by Cluster TOF-SIMS Imaging
Debois, D., Bralet, M.-P., Le Naour, F., Brunelle, A., & Laprévote, O. (2009) · Analytical Chemistry · doi:10.1021/ac900045m · Cited by 168
Optimizing UV laser focus profiles for improved MALDI performance
Holle, A., Haase, A., Kayser, M., & Höhndorf, J. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.1041 · Cited by 167
Lipid peroxidation in neurodegeneration: new insights into Alzheimerʼs disease
Arlt, S., Beisiegel†, U., & Kontush, A. (2002) · Current Opinion in Lipidology · doi:10.1097/00041433-200206000-00009 · Cited by 161
Mass spectrometric imaging of lipids using desorption electrospray ionization
Dill, A. L., Ifa, D. R., Manicke, N. E., Ouyang, Z., & Cooks, R. G. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.058 · Cited by 158
Touboul, D., Brunelle, A., Halgand, F., de la Porte, S., & Laprévôte, O. (2005) · Journal of Lipid Research · doi:10.1194/jlr.m500058-jlr200 · Cited by 138
Imaging mass spectrometry of natural products
Esquenazi, E., Yang, Y., Watrous, J. D., Gerwick, W. H., & Dorrestein, P. C. (2009) · Natural Product Reports · doi:10.1039/b915674g · Cited by 136
Woods, A. S., & Jackson, S. N. (2006) · The AAPS Journal · doi:10.1007/bf02854910 · Cited by 132
Fletcher, J. S., Sheraz, S., Henderson, A., Lockyer, N. P., & Vickerman, J. C. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4944 · Cited by 132
Imaging of Lipids in Atheroma by Desorption Electrospray Ionization Mass Spectrometry
Manicke, N. E., Nefliu, M., Wu, C., Woods, J. W., Reiser, V., Hendrickson, R. C., & Cooks, R. G. (2009) · Analytical Chemistry · doi:10.1021/ac901739s · Cited by 130
Liu, Y., Chen, Y., Momin, A. A., et al. (2010) · Molecular Cancer · doi:10.1186/1476-4598-9-186 · Cited by 130
Vitamin E Imaging and Localization in the Neuronal Membrane
Monroe, E. B., Jurchen, J. C., Lee, J., Rubakhin, S. S., & Sweedler, J. V. (2005) · Journal of the American Chemical Society · doi:10.1021/ja051223y · Cited by 129
Carado, A. J., Passarelli, M. K., Kozole, J., Wingate, J. E., Winograd, N., & Loboda, A. V. (2008) · Analytical Chemistry · doi:10.1021/ac801712s · Cited by 125
Self-citationLocalization of lipids in freeze-dried mouse brain sections by imaging TOF-SIMS
Sjövall, P., Johansson, B. A., & Lausmaa, J. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.02.126 · Cited by 117
MALDI-TOF and cluster-TOF-SIMS imaging of Fabry disease biomarkers
Touboul, D., Roy, S., Germain, D. P., Chaminade, P., Brunelle, A., & Laprévôte, O. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.027 · Cited by 115
Tahallah, N., Brunelle, A., de la Porte, S., & Laprévôte, O. (2007) · Journal of Lipid Research · doi:10.1194/jlr.m700421-jlr200 · Cited by 110
Debois, D., Hamze, K., Guérineau, V., Caër, J. L., Holland, I. B., Lopes, P., Ouazzani, J., Séror, S. J., Brunelle, A., & Laprévôte, O. (2008) · PROTEOMICS · doi:10.1002/pmic.200701025 · Cited by 105
Why don’t biologists use SIMS?
Heeren, R. M. A., McDonnell, L. A., Amstalden, E. R., Luxembourg, S. L., Altelaar, M. A. F., & Piersma, S. R. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.02.134 · Cited by 103
Depth Profiling Brain Tissue Sections with a 40 keV C60+ Primary Ion Beam
Jones, E. A., Lockyer, N. P., & Vickerman, J. C. (2008) · Analytical Chemistry · doi:10.1021/ac702127q · Cited by 96
Molecular imaging of adrenal gland by desorption electrospray ionization mass spectrometry
Wu, C., Ifa, D. R., Manicke, N. E., & Cooks, R. G. (2009) · The Analyst · doi:10.1039/b919816d · Cited by 94
Nygren, H., Börner, K., Hagenhoff, B., Malmberg, P., & Månsson, J. (2005) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2005.10.004 · Cited by 89
Molecular mass spectrometry imaging in biomedical and life science research
Pól, J., Strohalm, M., Havlı́ček, V., & Volný, M. (2010) · Histochemistry and Cell Biology · doi:10.1007/s00418-010-0753-3 · Cited by 89
Paglia, G., Ifa, D. R., Wu, C., Corso, G., & Cooks, R. G. (2010) · Analytical Chemistry · doi:10.1021/ac902325j · Cited by 86
McGuiness, C. L., Shaporenko, A., Zharnikov, M., Walker, A. V., & Allara, D. L. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp065173a · Cited by 86
Tissue imaging using MALDI-MS: a new frontier of histopathology proteomics
Fournier, I., Wisztorski, M., & Salzet, M. (2008) · Expert Review of Proteomics · doi:10.1586/14789450.5.3.413 · Cited by 86
Kurczy, M. E., Piehowski, P., Bell, C. T. V., Heien, M. L., Winograd, N., & Ewing, A. G. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0908101107 · Cited by 84
Self-citationMS/MS Methodology To Improve Subcellular Mapping of Cholesterol Using TOF-SIMS
Piehowski, P., Carado, A. J., Kurczy, M. E., Ostrowski, S. G., Heien, M. L., Winograd, N., & Ewing, A. G. (2008) · Analytical Chemistry · doi:10.1021/ac801591r · Cited by 84
Self-citationDesorption electrospray ionization imaging mass spectrometry of lipids in rat spinal cord
Girod, M., Shi, Y., Cheng, J., & Cooks, R. G. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.03.028 · Cited by 79
Roddy, T. P., Cannon, D. M., Meserole, C. A., Winograd, N., & Ewing, A. G. (2002) · Analytical Chemistry · doi:10.1021/ac0255734 · Cited by 79
Self-citationThiel, V., Heim, C., Arp, G., Hahmann, U., Sjövall, P., & Lausmaa, J. (2007) · Geobiology · doi:10.1111/j.1472-4669.2007.00119.x · Cited by 67
Hankin, J. A., & Murphy, R. C. (2010) · Analytical Chemistry · doi:10.1021/ac101079v · Cited by 67
Piwowar, A. M., Lockyer, N. P., & Vickerman, J. C. (2009) · Analytical Chemistry · doi:10.1021/ac8020888 · Cited by 61
Seyer, A., Einhorn, J., Brunelle, A., & Laprévôte, O. (2010) · Analytical Chemistry · doi:10.1021/ac902528t · Cited by 57
Stoeckli, M., Knochenmuss, R., McCombie, G., Mueller, D. R., Rohner, T. C., Staab, D., & Wiederhold, K. (2006) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(06)12007-8 · Cited by 52
Rauser, S., Deininger, S., Suckau, D., Höfler, H., & Walch, A. K. (2010) · Expert Review of Proteomics · doi:10.1586/epr.10.83 · Cited by 52
FAB/mass spectrometry of lipids
Matsubara, T. (1991) · Progress in Lipid Research · doi:10.1016/0163-7827(91)90001-l · Cited by 51
Distribution of cholesterol and galactosylceramide in rat cerebellar white matter
Börner, K., NYGREN, H., Hagenhoff, B., Malmberg, P., Tallarek, E., & Månsson, J. (2006) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2006.02.021 · Cited by 48
Magnusson, Y., Friberg, P., Sjövall, P., Dangardt, F., Malmberg, P., & Chen, Y. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00796.x · Cited by 43
Lanekoff, I., Kurczy, M. E., Hill, R., Fletcher, J. S., Vickerman, J. C., Winograd, N., Sjövall, P., & Ewing, A. G. (2010) · Analytical Chemistry · doi:10.1021/ac101243b · Cited by 38
Self-citationYang, H., Ishizaki, I., Sanada, N., Zaima, N., Sugiura, Y., Yao, I., Ikegami, K., & Setou, M. (2010) · Medical Molecular Morphology · doi:10.1007/s00795-009-0487-2 · Cited by 37
Pernber, Z., Richter, K., Månsson, J., & Nygren, H. (2006) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2006.12.007 · Cited by 37
Lipid imaging in the zebra finch brain with secondary ion mass spectrometry
Amaya, K. R., Monroe, E. B., Sweedler, J. V., & Clayton, D. F. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.032 · Cited by 34
Localization of cholesterol in rat cerebellum with imaging TOF-SIMS
Nygren, H., Börner, K., Malmberg, P., & Hagenhoff, B. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.02.197 · Cited by 29
Cited by
Sample preparation for mass spectrometry imaging: Small mistakes can lead to big consequences
Goodwin, R. J. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.012 · Cited by 313
Taylor, M. J., Lukowski, J. K., & Anderton, C. R. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00439 · Cited by 302
Cholesterol as a causative factor in Alzheimer's disease: a debatable hypothesis
Wood, W. G., Li, L., Müller, W. E., & Eckert, G. P. (2014) · Journal of Neurochemistry · doi:10.1111/jnc.12637 · Cited by 194
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Metadata
- Authors
- Passarelli, M. K., & Winograd, N.
- Venue
- Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 1811
- Issue
- 11
- Pages
- 976-990
- ISSN
- 1388-1981 (ISSN-L)
- OpenAlex
- W2077692714
- Cited by
- 314
- References
- 68
- FWCI
- 24.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.