Additively manufactured biodegradable porous magnesium implants for elimination of implant-related infections: An in vitro and in vivo study
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Magnesium (Mg) alloys that have both antibacterial and osteogenic properties are suitable candidates for orthopedic implants. However, the fabrication of ideal Mg implants suitable for bone repair remains challenging because it requires implants with interconnected pore structures and personalized geometric shapes. In this study, we fabricated a porous 3D-printed Mg-Nd-Zn-Zr (denoted as JDBM) implant with suitable mechanical properties using selective laser melting technology. The 3D-printed JDBM implant exhibited cytocompatibility in MC3T3-E1 and RAW267.4 cells and excellent osteoinductivity in vitro. Furthermore, the implant demonstrated excellent antibacterial ratios of 90.0% and 92.1% for methicillin-resistant S. aureus (MRSA) and Escherichia coli, respectively. The 3D-printed JDBM implant prevented MRSA-induced implant-related infection in a rabbit model and showed good in vivo biocompatibility based on the results of histological evaluation, blood tests, and Mg2+ deposition detection. In addition, enhanced inflammatory response and TNF-α secretion were observed at the bone-implant interface of the 3D-printed JDBM implants during the early implantation stage. The high Mg2+ environment produced by the degradation of 3D-printed JDBM implants could promote M1 phenotype of macrophages (Tnf, iNOS, Ccl3, Ccl4, Ccl5, Cxcl10, and Cxcl2), and enhance the phagocytic ability of macrophages. The enhanced immunoregulatory effect generated by relatively fast Mg2+ release and implant degradation during the early implantation stage is a potential antibacterial mechanism of Mg-based implant. Our findings indicate that 3D-printed porous JDBM implants, having both antibacterial property and osteoinductivity, hold potential for future orthopedic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and the Inflammatory Response: Potential Physiopathological Implications
Mazur, A., Maier, J. A. M., Rock, E., Gueux, E., Nowacki, W., & Rayssiguier, Y. (2007) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2006.03.031 · Cited by 474
Dopamine Modified Organic–Inorganic Hybrid Coating for Antimicrobial and Osteogenesis
Li, M., Liu, X., Xu, Z., Yeung, K. W. K., & Wu, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b09457 · Cited by 154
Alkalization is responsible for antibacterial effects of corroding magnesium
Rahim, M. I., Eifler, R., Rais, B., & Mueller, P. P. (2015) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35503 · Cited by 111
Cited by
Zhao, Y., He, P., Yao, J., Li, M., Wang, B., Han, L., Huang, Z., Guo, C., Bai, J., Xue, F., et al. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122237 · Cited by 101
Zhao, Y., He, P., Wang, B., Bai, J., Xue, F., & Chu, C. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.12.004 · Cited by 60
Biodegradable bone implants as a new hope to reduce device-associated infections-a systematic review
Paiva, J. C. C., Oliveira, L., Vaz, M. F., & Costa-de-Oliveira, S. (2022) · Bioengineering · doi:10.3390/bioengineering9080409 · Cited by 53
“Additionally, the observation period ranged from 4 weeks [69,88] to 120 days [79].”
BackgroundMethodInfluentialWang, Z., Liu, B., Yin, B., Zheng, Y., Tian, Y., & Wen, P. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.1066103 · Cited by 30
“, 2022), and inhibition of implant infections (Xie et al., 2022) using AM combined with Mg alloys.”
BackgroundFarshid, S., Kharaziha, M., Salehi, H., & Ganjalikhani Hakemi, M. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c11184 · Cited by 23
Metadata
- Authors
- Xie, K., Wang, N., Guo, Y., Zhao, S., Tan, J., Wang, L., Li, G., Wu, J., Yang, Y., Xu, W., Chen, J., Jiang, W., Fu, P., & Hao, Y.
- Venue
- Bioactive Materials
- Publisher
- Elsevier BV
- Published
- 2022-02
- Volume
- 8
- Pages
- 140-152
- ISSN
- 2097-1192 (ISSN-L)
- 2452-199X
- OpenAlex
- W3180714961
- Cited by
- 112
- References
- 3
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Additively manufactured biodegradable porous magnesium implants for elimination of implant-related infections: An in vitro and in vivo study. https://app.cochat.ai/papers/10.1016/j.bioactmat.2021.06.032
- The paper
- Xie, K., Wang, N., Guo, Y., Zhao, S., Tan, J., Wang, L., Li, G., Wu, J., Yang, Y., Xu, W., Chen, J., Jiang, W., Fu, P., & Hao, Y. (2022). Additively manufactured biodegradable porous magnesium implants for elimination of implant-related infections: An in vitro and in vivo study. Bioactive Materials. https://doi.org/10.1016/j.bioactmat.2021.06.032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.