Prevention of Staphylococcus epidermidis biofilm formation using a low-temperature processed silver-doped phenyltriethoxysilane sol–gel coating
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Sol-gel coatings which elute bioactive silver ions are presented as a potential solution to the problem of biofilm formation on indwelling surfaces. There is evidence that high-temperature processing of such materials can lead to diffusion of silver away from the coating surface, reducing the amount of available silver. In this study, we report the biofilm inhibition of a Staphylococcus epidermidis biofilm using a low-temperature processed silver-doped phenyltriethoxysilane sol-gel coating. The incorporation of a silver salt into a sol-gel matrix resulted in an initial high release of silver in de-ionised water and physiological buffered saline (PBS), followed by a lower sustained release for at least 6 days-as determined by graphite furnace-atomic absorption spectroscopy (GF-AAS). The release of silver ions from the sol-gel coating reduced the adhesion and prevented formation of a S. epidermidis biofilm over a 10-day period. The presence of surface silver before and after 24 h immersion in PBS was confirmed by X-ray photoelectron spectroscopy (XPS). These silver-doped coatings also exhibited significant antibacterial activity against planktonic S. epidermidis. A simple test to visualise the antibacterial effect of silver release coatings on neighbouring bacterial cultures is also reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644 · cited 2×
“Considering that a high initial release of antibacterial agent during the early stages of device insertion is critical to prevent bacterial attachment, a reduction in the availability of surface silver is undesirable [2].”
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
Cited by
Dastjerdi, R., & Montazer, M. (2010) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2010.03.029 · Cited by 1,355
Monteiro, D. R., Gorup, L. F., Takamiya, A. S., Ruvollo-Filho, A. C., Camargo, E. R. D., & Barbosa, D. B. (2009) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2009.01.017 · Cited by 801
Novel Strategies for the Prevention and Treatment of Biofilm Related Infections
Chen, M., Yu, Q., & Sun, H. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918488 · Cited by 429
“biomaterials using coating technology [46,47].”
Srinivasan, R., Santhakumari, S., Poonguzhali, P., Geetha, M., Dyavaiah, M., & Xiangmin, L. (2021) · Frontiers in Microbiology · doi:10.3389/fmicb.2021.676458 · Cited by 352
Plasma-assisted surface modification of organic biopolymers to prevent bacterial attachment
Bazaka, K., Jacob, M. V., Crawford, R. J., & Ivanova, E. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.024 · Cited by 296
Silver compounds used in dentistry for caries management: A review
Peng, J. J.-Y., Botelho, M. G., & Matinlinna, J. P. (2012) · Journal of Dentistry · doi:10.1016/j.jdent.2012.03.009 · Cited by 290
Current and Recent Advanced Strategies for Combating Biofilms
Sadekuzzaman, M., Yang, S., Mizan, M. F. R., & Ha, S. D. (2015) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12144 · Cited by 276
Current perspectives of nanoparticles in medical and dental biomaterials
Ibrahim, M. (2012) · The Journal of Biomedical Research · doi:10.7555/jbr.26.20120027 · Cited by 216
“[15] Stobie N, Duffy B, McCormack DE, Colreavy J, Hidalgo”
BackgroundMonteiro, D. R., Gorup, L. F., Silva, S., Negri, M., de Camargo, E. R., Oliveira, R., Barbosa, D. B., & Henriques, M. (2011) · Biofouling · doi:10.1080/08927014.2011.599101 · Cited by 205
In Vitro Antibacterial Activity and Mechanism of Silver Nanoparticles against Foodborne Pathogens
Rajeshkumar, S., & Malarkodi, C. (2014) · Bioinorganic Chemistry and Applications · doi:10.1155/2014/581890 · Cited by 187
“These materials novelty in life form a continuing antibacterial material with high temperature stability and low volatility [33].”
BackgroundBioactive sol‐gel glasses: Processing, properties, and applications
Baino, F., Fiume, E., Miola, M., & Verné, E. (2018) · International Journal of Applied Ceramic Technology · doi:10.1111/ijac.12873 · Cited by 173
Cai, W., Wu, J., Xi, C., & Meyerhoff, M. E. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.07.027 · Cited by 77
Ardjoum, N., Shankar, S., Chibani, N., Salmieri, S., & Lacroix, M. (2021) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2021.107000 · Cited by 61
Thromboresistant/anti-biofilm catheters via electrochemically modulated nitric oxide release
Ren, H., Colletta, A., Koley, D., Wu, J., Xi, C., Major, T. C., Bartlett, R. H., & Meyerhoff, M. E. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2014.12.003 · Cited by 55
Metadata
- Authors
- Stobie, N., Duffy, B., McCormack, D. E., Colreavy, J., Hidalgo, M., McHale, P., & Hinder, S. J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 29
- Issue
- 8
- Pages
- 963-969
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1993411367
- Cited by
- 175
- References
- 2
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.