Gel spinning of silk tubes for tissue engineering
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Tubular vessels for tissue engineering are typically fabricated using a molding, dipping, or electrospinning technique. While these techniques provide some control over inner and outer diameters of the tube, they lack the ability to align the polymers or fibers of interest throughout the tube. This is an important aspect of biomaterial composite structure and function for mechanical and biological impact of tissue outcomes. We present a novel aqueous process system to spin tubes from biopolymers and proteins such as silk fibroin. Using silk as an example, this method of winding an aqueous solution around a reciprocating rotating mandrel offers substantial improvement in the control of the tube properties, specifically with regard to winding pattern, tube porosity, and composite features. Silk tube properties are further controlled via different post-spinning processing mechanisms such as methanol-treatment, air-drying, and lyophilization. This approach to tubular scaffold manufacture offers numerous tissue engineering applications such as complex composite biomaterial matrices, blood vessel grafts and nerve guides, among others.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Altman, G. H., Diaz, F., Jakuba, C., Calabro, T., Horan, R. L., Chen, J., Lu, H., Richmond, J., & Kaplan, D. L. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00353-8 · Cited by 3,458
Self-citationFabrication of a new tubular fibrous PLCL scaffold for vascular tissue engineering
Kim, S.-H., Kwon, J. H., Chung, M. S., Chung, E., Jung, Y., Kim, S. H., & Kim, Y. H. (2006) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856206778937244 · Cited by 55 · cited 1×
“Gel spinning processes have been previously used to form uniform tubes or fibers from polymers such as poly(L-lactide-co-caprolactone) (PLCL) [15], chitosan [16], and gelatin [17], among others.”
Cited by
Materials fabrication from Bombyx mori silk fibroin
Rockwood, D. N., Preda, R. C., Yücel, T., Wang, X., Lovett, M. L., & Kaplan, D. L. (2011) · Nature Protocols · doi:10.1038/nprot.2011.379 · Cited by 3,066
Self-citationSilk fibroin biomaterials for tissue regenerations
Kundu, B., Rajkhowa, R., Kundu, S. C., & Wang, X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.043 · Cited by 1,391
“3-D constructs of nano-fibers are used as blood vessel grafts and nerve guides [88,89].”
MethodVillification: How the Gut Gets Its Villi
Shyer, A. E., Tallinen, T., Nerurkar, N. L., Wei, Z., Gil, E. S., Kaplan, D. L., Tabin, C. J., & Mahadevan, L. (2013) · Science · doi:10.1126/science.1238842 · Cited by 562
Self-citationBioactive polymeric scaffolds for tissue engineering
Stratton, S., Shelke, N. B., Hoshino, K., Rudraiah, S., & Kumbar, S. G. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.11.001 · Cited by 469
“To fabricate 3D scaffolds of silk biomaterials, freeze drying, electrospinning, and 3D printing has been shown to be an effective technique [73,81,82].”
Silk proteins for biomedical applications: Bioengineering perspectives
Kundu, B., Kurland, N. E., Bano, S., Patra, C., Engel, F. B., Yadavalli, V. K., & Kundu, S. C. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.09.002 · Cited by 451
Silk-based biomaterials for sustained drug delivery
Yucel, T., Lovett, M. L., & Kaplan, D. L. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.059 · Cited by 359
Self-citationYan, L.-P., Oliveira, J. M., Oliveira, A. L., Caridade, S. G., Mano, J. F., & Reis, R. L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.037 · Cited by 294
Zheng, W., Wang, Z., Song, L., Zhao, Q., Zhang, J., Li, D., Wang, S., Han, J., Zheng, X.-L., Yang, Z., et al. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.12.047 · Cited by 288
Mirahmadi, F., Tafazzoli-Shadpour, M., Shokrgozar, M. A., & Bonakdar, S. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.07.043 · Cited by 232
Yao, Y., Wang, J., Cui, Y., Xu, R., Wang, Z., Zhang, J., Wang, K., Li, Y., Zhao, Q., & Kong, D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.042 · Cited by 226
Silk‐Based Biomaterials in Biomedical Textiles and Fiber‐Based Implants
Li, G., Li, Y., Chen, G., He, J., Han, Y., Wang, X., & Kaplan, D. L. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500002 · Cited by 199
Self-citationFukunishi, T., Best, C. A., Sugiura, T., Shoji, T., Yi, T., Udelsman, B., Ohst, D., Ong, C. S., Zhang, H., Shinoka, T., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0158555 · Cited by 188
Tubular silk scaffolds for small diameter vascular grafts
Lovett, M., Eng, G., Kluge, J., Cannizzaro, C., Vunjak-Novakovic, G., & Kaplan, D. L. (2010) · Organogenesis · doi:10.4161/org.6.4.13407 · Cited by 169
“5% bovine serum albumin (BSA) serving as the positive and tubular conduits with fine control over tube properties (mechanics, lifetime, structural features).(10) In the present study, the focus was placed on using lyophilized silk tubular grafts that have a long shelf life, can be designed to achieve structural and me…”
BackgroundMethodSelf-citationDi Buduo, C. A., Wray, L. S., Tozzi, L., Malara, A., Chen, Y., Ghezzi, C. E., Smoot, D., Sfara, C., Antonelli, A., Spedden, E., et al. (2015) · Blood · doi:10.1182/blood-2014-08-595561 · Cited by 162
Self-citation
Metadata
- Authors
- Lovett, M. L., Cannizzaro, C. M., Vunjak-Novakovic, G., & Kaplan, D. L.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 29
- Issue
- 35
- Pages
- 4650-4657
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2022478950
- Cited by
- 147
- References
- 2
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.