A small diameter, fibrous vascular conduit generated from a poly(ester urethane)urea and phospholipid polymer blend
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The thrombotic and hyperplastic limitations associated with synthetic small diameter vascular grafts has generated sustained interest in finding a tissue engineering solution for autologous vascular segment generation in situ. One approach is to place a biodegradable scaffold at the site that would provide acute mechanical support while vascular tissue develops. To generate a scaffold that possessed both non-thrombogenic character and mechanical properties appropriate for vascular tissue, a biodegradable poly(ester urethane)urea (PEUU) and non-thromobogenic bioinspired phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine-co-methacryloyloxyethyl butylurethane) (PMBU) were blended at PMBU weight fractions of 0–15% and electrospun to create fibrous scaffolds. The composite scaffolds were flexible with breaking strains exceeding 300%, tensile strengths of 7–10 MPa and compliances of 2.9–4.4 × 10−4 mmHg−1. In vitro platelet deposition on the scaffold surfaces significantly decreased with increasing PMBU content. Rat smooth muscle cell proliferation was also inhibited on PEUU/PMBU blended scaffolds with greater inhibition at higher PMBU content. Fibrous vascular conduits (1.3 mm inner diameter) implanted in the rat abdominal aorta for 8 weeks showed greater patency for grafts with 15% PMBU blending versus PEUU without PMBU (67% versus 40%). A thin neo-intimal layer with endothelial coverage and good anastomotic tissue integration was seen for the PEUU/PMBU vascular grafts. These results are encouraging for further evaluation of this technique in larger diameter applications for longer implant periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Manufacture of elastic biodegradable PLCL scaffolds for mechano-active vascular tissue engineering
Jeong, S. I., Kim, S. H., Kim, Y. H., Jung, Y., Kwon, J. H., Kim, B.-S., & Lee, Y. M. (2004) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856204323046906 · Cited by 181
Taite, L. J., Yang, P., Jun, H., & West, J. L. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30850 · Cited by 136 · cited 1×
“To reduce thrombogenicity, some notable techniques including surface or compositional modification with non-thrombogenic substances [9–12], endothelialization [13– 15], nitric oxide release [16] and stem cell seeding [17,18] have been developed.”
Method
Cited by
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Ren, X., Feng, Y., Guo, J., Wang, H., Li, Q., Yang, J., Hao, X., Lv, J., Ma, N., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00483c · Cited by 573
Effects of Humidity and Solution Viscosity on Electrospun Fiber Morphology
Nezarati, R. M., Eifert, M. B., & Cosgriff-Hernandez, E. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0671 · Cited by 459
Electrospun fibers for tissue engineering, drug delivery, and wound dressing
Goh, Y.-F., Shakir, I., & Hussain, R. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7145-8 · Cited by 318
Phosphorus-Containing Polymers: A Great Opportunity for the Biomedical Field
Monge, S., Canniccioni, B., Graillot, A., & Robin, J.-J. (2011) · Biomacromolecules · doi:10.1021/bm2004803 · Cited by 317
Yue, W.-W., Li, H.-J., Xiang, T., Qin, H., Sun, S.-D., & Zhao, C.-S. (2013) · Journal of Membrane Science · doi:10.1016/j.memsci.2013.06.029 · Cited by 299
Zheng, W., Wang, Z., Song, L., Zhao, Q., Zhang, J., Li, D., Wang, S., Han, J., Zheng, X.-L., Yang, Z., et al. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.12.047 · Cited by 288
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Recent advancements in electrospinning design for tissue engineering applications: A review
Kishan, A. P., & Cosgriff‐Hernandez, E. M. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36124 · Cited by 261
Dual-delivery of VEGF and PDGF by double-layered electrospun membranes for blood vessel regeneration
Zhang, H., Jia, X., Han, F., Zhao, J., Zhao, Y., Fan, Y., & Yuan, X. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.12.005 · Cited by 250
Szewczyk, P. K., & Stachewicz, U. (2020) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102315 · Cited by 219
Hong, Y., Huber, A., Takanari, K., Amoroso, N. J., Hashizume, R., Badylak, S. F., & Wagner, W. R. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.025 · Cited by 217
Self-citationFabrication, biological effects, and medical applications of calcium phosphate nanoceramics
Hong, Y., Fan, H., Li, B., Guo, B., Liu, M., & Zhang, X. (2010) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2010.06.010 · Cited by 215
Self-citationFukunishi, T., Best, C. A., Sugiura, T., Shoji, T., Yi, T., Udelsman, B., Ohst, D., Ong, C. S., Zhang, H., Shinoka, T., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0158555 · Cited by 188
In Vivo Applications of Electrospun Tissue-Engineered Vascular Grafts: A Review
Rocco, K. A., Maxfield, M. W., Best, C. A., Dean, E. W., & Breuer, C. K. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0123 · Cited by 165
Rational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
Self-citationTakanari, K., Hong, Y., Hashizume, R., Huber, A., Amoroso, N. J., D'Amore, A., Badylak, S. F., & Wagner, W. R. (2016) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1834 · Cited by 35
“Consistent with previous reports (Hong et al., 2008, 2009; Hashizume et al., 2010), the mechanical properties of the scaffold changed over the implantation period.”
BackgroundMethodResultSelf-citation
Metadata
- Authors
- Hong, Y., Ye, S.-H., Nieponice, A., Soletti, L., Vorp, D. A., & Wagner, W. R.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 30
- Issue
- 13
- Pages
- 2457-2467
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1976221882
- Cited by
- 157
- References
- 2
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.