A mitochondria-targeted ratiometric fluorescent probe to monitor endogenously generated sulfur dioxide derivatives in living cells
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Sulfur dioxide (SO2) can be endogenously produced by enzymes in mitochondria during oxidation of H2S or sulphur-containing amino acids, and plays important roles in several physiological processes. However, the design and synthesis of fluorescent probes which can detect mitochondrial SO2 and its derivatives in living cells still remain unresolved. Herein, we report the preparation of a lipophilic cationic dye 1 (Mito-Ratio-SO2), which targets the mitochondria in living cells and is sensitive to the presence of SO2 derivatives. The ratiometric probe Mito-Ratio-SO2 displays a 170 nm blue-shift in emission with two well-resolved emission bands upon addition of sulfite. Mechanistic studies indicate that three probe-SO2 adducts coexist after reaction, as supported by liquid chromatography and density function theory investigations. Importantly, the ratiometric probe is highly selective for sulfite over other bio-species including H2S. Fluorescence co-localization studies indicate that the probe localizes solely in the mitochondria of HeLa cells. Last but not least, fluorescent imaging of HeLa cells successfully demonstrates the detection of intrinsically generated intracellular SO2 derivatives in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitochondria and cell death: outer membrane permeabilization and beyond
Tait, S. W. G., & Green, D. R. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2952 · Cited by 2,593
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35313j · Cited by 1,822
Self-citationFluorescent chemosensors for Zn2+
Xu, Z., Yoon, J., & Spring, D. R. (2010) · Chemical Society Reviews · doi:10.1039/b916287a · Cited by 982
Fan, J., Hu, M., Zhan, P., & Peng, X. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35273g · Cited by 821
Outdoor Air Pollution: Nitrogen Dioxide, Sulfur Dioxide, and Carbon Monoxide Health Effects
Chen, T.-M., Kuschner, W. G., Gokhale, J., & Shofer, S. (2007) · The American Journal of the Medical Sciences · doi:10.1097/maj.0b013e31803b900f · Cited by 729
New fluorescent chemosensors for metal ions in solution
Formica, M., Fusi, V., Giorgi, L., & Micheloni, M. (2011) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2011.09.010 · Cited by 722
Mitochondria in health and disease: perspectives on a new mitochondrial biology
Duchen, M. R. (2004) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2004.03.001 · Cited by 721
Dealing with methionine/homocysteine sulfur: cysteine metabolism to taurine and inorganic sulfur
Stipanuk, M. H., & Ueki, I. (2011) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-009-9006-9 · Cited by 494
Mitochondria-Targeted Small Molecule Therapeutics and Probes
Smith, R. A. J., Hartley, R. C., & Murphy, M. P. (2011) · Antioxidants & Redox Signaling · doi:10.1089/ars.2011.3969 · Cited by 399
Cited by
Zielonka, J., Joseph, J., Sikora, A., Hardy, M., Ouari, O., Vasquez-Vivar, J., Cheng, G., Lopez, M., & Kalyanaraman, B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00042 · Cited by 1,683
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Discerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Self-citationFluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Cheng, D., Pan, Y., Wang, L., Zeng, Z., Yuan, L., Zhang, X., & Chang, Y.-T. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b10508 · Cited by 500
Self-citationDual-Site Fluorescent Probe for Visualizing the Metabolism of Cys in Living Cells
Yue, Y., Huo, F., Ning, P., Zhang, Y., Chao, J., Meng, X., & Yin, C. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12845 · Cited by 499
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b01374 · Cited by 308
Self-citationFluorescent probes for the selective detection of chemical species inside mitochondria
Xu, Z., & Xu, L. (2016) · Chemical Communications · doi:10.1039/c5cc09248e · Cited by 291
Xu, J., Pan, J., Jiang, X., Qin, C., Zeng, L., Zhang, H., & Zhang, J. F. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.049 · Cited by 278
Fluorescent probes for the detection of disease-associated biomarkers
Dou, W.-T., Han, H.-H., Sedgwick, A. C., Zhu, G.-B., Zang, Y., Yang, X.-R., Yoon, J., James, T. D., Li, J., & He, X.-P. (2022) · Science Bulletin · doi:10.1016/j.scib.2022.01.014 · Cited by 266
Reaction-based fluorescent probes for SO2 derivatives and their biological applications
Li, K., Li, L.-L., Zhou, Q., Yu, K.-K., Kim, J. S., & Yu, X.-Q. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.03.001 · Cited by 225
Zhang, Y., Guan, L., Yu, H., Yan, Y., Du, L., Liu, Y., Sun, M., Huang, D., & Wang, S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00061 · Cited by 198
Mitochondria-Targeted Fluorescent Probe for Imaging Hydrogen Peroxide in Living Cells
Xu, J., Zhang, Y., Yu, H., Gao, X., & Shao, S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04424 · Cited by 191
Responsive small-molecule luminescence probes for sulfite/bisulfite detection in food samples
Feng, H., Liu, J., Qaitoon, A., Meng, Q., Sultanbawa, Y., Zhang, Z., Xu, Z. P., & Zhang, R. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116199 · Cited by 173
Metadata
- Authors
- Xu, W., Teoh, C. L., Peng, J., Su, D., Yuan, L., & Chang, Y.-T.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 56
- Pages
- 1-9
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2026642379
- Cited by
- 252
- References
- 56
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.