The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Open accessAbstract
Micro-sized electrodes are essential for highly sensitive communication at the neural interface with superior spatial resolution. However, such small electrodes inevitably suffer from high electrical impedance and thus high levels of thermal noise deteriorating the signal to noise ratio. In order to overcome this problem, a nanostructured Pt-coating was introduced as add-on functionalization for impedance reduction of small electrodes. In comparison to platinum black deposition, all used chemicals in the deposition process are free from cytotoxic components. The grass-like nanostructure was found to reduce the impedance by almost two orders of magnitude compared to untreated samples which was lower than what could be achieved with conventional electrode coatings like IrOx or PEDOT. The realization of the Pt-grass coating is performed via a simple electrochemical process which can be applied to virtually any possible electrode type and accordingly shows potential as a universal impedance reduction strategy. Elution tests revealed non-toxicity of the Pt-grass and the coating was found to exhibit strong adhesion to the metallized substrate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The deposition processes for platinum black have reportedly caused cytotoxic reactions due to lead traces found in the electroplating electrolyte (Schuettler et al. 2005b). This was not observed for nanostructured platinum grass (Boehler et al. 2015).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Boehler et al. 2015
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationThe electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 459
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 366
Deep Brain Stimulation for Psychiatric Disorders
Holtzheimer, P. E., & Mayberg, H. S. (2011) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-061010-113638 · Cited by 346
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343
Self-citationSun, S., Jaouen, F., & Dodelet, J. (2008) · Advanced Materials · doi:10.1002/adma.200800491 · Cited by 331
Organic electrode coatings for next-generation neural interfaces
Robles, U. A. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 266
Substrate dependent stability of conducting polymer coatings on medical electrodes
Green, R. A., Hassarati, R. T., Bouchinet, L., Lee, C. S., Cheong, G. L. M., Yu, J., Dodds, C. W. D., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.017 · Cited by 207
Tanihara, M., Suzuki, Y., Yamamoto, E., Noguchi, A., & Mizushima, Y. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2 · Cited by 205
Blood pressure control with selective vagal nerve stimulation and minimal side effects
Plachta, D. T. T., Gierthmuehlen, M., Cota, O. F., Espinosa, N., Boeser, F., Herrera, T. C., Stieglitz, T., & Zentner, J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036011 · Cited by 187
Self-citationGrowing Pt Nanowires as a Densely Packed Array on Metal Gauze
Lee, E. P., Peng, Z., Cate, D. M., Yang, H., Campbell, C. T., & Xia, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja074312e · Cited by 184
Chapman, C. A. R., Chen, H., Stamou, M., Biener, J., Biener, M. M., Lein, P. J., & Şeker, E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b00410 · Cited by 150
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Desai, S. A. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00005 · Cited by 124
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
Thin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118
Self-citationElectrical Stimuli in the Central Nervous System Microenvironment
Thompson, D. M., Koppes, A. N., Hardy, J. G., & Schmidt, C. E. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120655 · Cited by 108
Preparation of strongly adherent platinum black coatings
Marrese, C. A. (1987) · Analytical Chemistry · doi:10.1021/ac00128a049 · Cited by 96
Stability of poly(3,4‐ethylene dioxythiophene) materials intended for implants
Thaning, E., Asplund, M., Nyberg, T., Inganäs, O., & von Holst, H. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31597 · Cited by 92
Self-citationBionic vision: system architectures – a review
Guenther, T., Lovell, N. H., & Suaning, G. J. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.58 · Cited by 78
Laser patterning of platinum electrodes for safe neurostimulation
Green, R. A., Matteucci, P. B., Dodds, C. W. D., Palmer, J., Dueck, W. F., Hassarati, R. T., Byrnes-Preston, P., Lovell, N. H., & Suaning, G. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056017 · Cited by 77
Managing Chronic Pain With Spinal Cord Stimulation
Epstein, L. J., & Palmieri, M. (2012) · Mount Sinai Journal of Medicine A Journal of Translational and Personalized Medicine · doi:10.1002/msj.21289 · Cited by 68
Brain–computer interfaces: an overview of the hardware to record neural signals from the cortex
Stieglitz, T., Rubehn, B., Henle, C., Kisban, S., Herwik, S., Ruther, P., & Schüettler, M. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17521-0 · Cited by 63
Self-citationOn the Stability of Poly‐Ethylenedioxythiopene as Coating Material for Active Neural Implants
Boretius, T., Schüettler, M., & Stieglitz, T. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01210.x · Cited by 52
Self-citationBoehler, C., & Asplund, M. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35252 · Cited by 47
Self-citationFabrication of strongly adherent platinum black coatings on microelectrodes array
Tang, R., Pei, W., Chen, S., Zhao, H., Chen, Y., Han, Y. F., Wang, C., & Chen, H. (2013) · Science China Information Sciences · doi:10.1007/s11432-013-4825-6 · Cited by 44
Human control model in teleoperation rendezvous
Zhang, B., Li, H., & Tang, G.-J. (2014) · Science China Information Sciences · doi:10.1007/s11432-013-5055-7 · Cited by 42
Schüettler, M. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352254 · Cited by 39
The influence of gold surface texture on microglia morphology and activation
Tan, Y. H., Terrill, S. E., Paranjape, G. S., Stine, K. J., & Nichols, M. R. (2013) · Biomaterials Science · doi:10.1039/c3bm60096c · Cited by 30
High-porous platinum electrodes for functional electrical stimulation
Boretius, T., Jurzinsky, T., Koehler, C., Kerzenmacher, S., Hillebrecht, H., & Stieglitz, T. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091336 · Cited by 23
Self-citationCytotoxicity of platinum black
Schüettler, M., Doerge, T., Wien, S. L., Becker, S., Staiger, A., Hanauer, M., Kammer, S., & Stieglitz, T. (2005) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · Cited by 18
Self-citationEffects of electrode size on the performance of neural recording microelectrodes
Hughes, M. P., Bustamante, K. D., Banks, D., & Ewins, D. J. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893776 · Cited by 14
Arrayed hybrid nanoporous Pt pillars
Park, S., Song, Y. J., Boo, H., Han, J., & Chung, T. D. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.09.036 · Cited by 11
Cited by
Sorted by citations
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Two-Dimensional Ti 3 C 2 MXene for High-Resolution Neural Interfaces
Driscoll, N., Richardson, A. G., Maleski, K., Anasori, B., Adewole, D. O., Lelyukh, P., Escobedo, L., Cullen, D. K., Lucas, T. H., Gogotsi, Y. G., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b06014 · Cited by 316
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 324
Self-citationMachine Learning‐Driven Biomaterials Evolution
Suwardi, A., Wang, F., Xue, K., Han, M., Teo, P., Wang, P., Wang, S., Liu, Y., Ye, E., Zibiao, L., et al. (2021) · Advanced Materials · doi:10.1002/adma.202102703 · Cited by 313
Emerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 299
Metadata
- Authors
- Boehler, C., Stieglitz, T., & Asplund, M.
- Affiliations
- University of Freiburg (DE)
- Corresponding author
- Boehler, C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2015-10
- Volume
- 67
- Pages
- 346-353
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1190686642
- Cited by
- 179
- References
- 35
- Citations by year
- 2026: 16 · 2025: 19 · 2024: 19 · 2023: 21 · 2022: 21 · 2021: 17 · 2020: 19 · 2019: 22 · 2018: 10 · 2017: 11 · 2016: 4
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Biomaterials (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- FreiDok plus (Universitätsbibliothek Freiburg) (submittedVersion)
- Funders
- German Research Foundation (EXC 1086)
- Freiburg Institute for Advanced Studies (FRIAS), funded by the German Excellence Initiative
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- neural microelectrodes, platinum coating, platinum black, electrodeposition, neural interfaces, thermal noise, signal-to-noise ratio, electrode functionalization, cytotoxicity, coating adhesion
- MeSH terms
- Cell Survival, Humans, Imides, Microelectrodes, Neurons, Platinum, Electric Impedance, Cell Line, Tumor, Nanostructures, Electrochemical Techniques, Optical Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review