CoChat

Microdevice arrays with strain sensors for 3D mechanical stimulation and monitoring of engineered tissues

Liu, Haijiao, MacQueen, Luke A., Usprech, Jenna F., Maleki, Hoda, Sider, Krista L., Doyle, Matthew G., Sun, Yu, Simmons, Craig A. · 2018 · Biomaterials
Cited by 46

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Native and engineered tissue development are regulated by the integrative effects of multiple microenvironmental stimuli. Microfabricated bioreactor array platforms can efficiently dissect cue-response networks, and have recently integrated critical 2D and 3D mechanical stimulation for greater physiological relevance. However, a limitation of these approaches is that assessment of tissue functional properties is typically limited to end-point analyses. Here we report a new deformable membrane platform with integrated strain sensors that enables mechanical stretching or compression of 3D cell-hydrogel arrays and simultaneous measurement of hydrogel construct stiffness in situ. We tested the ability of the integrated strain sensors to measure the evolution of the stiffness of cell-hydrogel constructs for two cases. First, we demonstrated in situ stiffness monitoring of degradable poly (ethylene glycol)-norbornene (PEG-NB) hydrogels embedded with mesenchymal stromal cells (MSCs) and cultured with or without cyclic tensile stimulation for up to 15 days. Whereas statically-cultured hydrogels degraded and softened throughout the culture period, mechanically-stimulated gels initially softened and then recovered their stiffness corresponding to extensive cell network and collagen production. Second, we demonstrated in situ measurement of compressive stiffening of MSC-seeded PEG-NB gels cultured statically under osteogenic conditions, corresponding to increased mineralization and cellularization. This measurement technique can be generalized to other relevant bioreactor and organ-on-a-chip platforms to facilitate online, non-invasive, and high-throughput functional analysis, and to provide insights into the dynamics of engineered tissue development that are otherwise not available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2018.04.041

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 46

Metadata

Authors
Liu, H., MacQueen, L. A., Usprech, J. F., Maleki, H., Sider, K. L., Doyle, M. G., Sun, Y., & Simmons, C. A.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2018-07
Volume
172
Pages
30-40
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2802802359
Cited by
46
References
10
FWCI
1.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microdevice arrays with strain sensors for 3D mechanical stimulation and monitoring of engineered tissues. https://app.cochat.ai/papers/10.1016/j.biomaterials.2018.04.041
The paper
Liu, H., MacQueen, L. A., Usprech, J. F., Maleki, H., Sider, K. L., Doyle, M. G., Sun, Y., & Simmons, C. A. (2018). Microdevice arrays with strain sensors for 3D mechanical stimulation and monitoring of engineered tissues. Biomaterials. https://doi.org/10.1016/j.biomaterials.2018.04.041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.