Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Abstract Implantable neural microelectrodes are integral components of neuroprosthetic technologies and can transform treatments for many neural-mediated disorders. However, dielectric material degradation during long-term (> 1 year) indwelling periods restricts device functional lifetimes to a few years. This comprehensive work carefully investigates in vivo material degradation and also explores the ability of in vitro Reactive Accelerated Aging (RAA) to evaluate implant stability. Parylene C-coated Utah electrode arrays (UEAs) implanted in feline peripheral nerve for 3.25 years were explanted and compared to RAA-processed devices, aged in phosphate buffered saline (PBS) + 20 mM H 2 O 2 at either 67 or 87 °C (28 or 7 days, respectively). Electron microscopy revealed similar physical damage characteristics between explants and RAA (87° C) devices. Parylene C degradation was overwhelmingly apparent for UEAs from both RAA cohorts. Controls aged in PBS alone displayed almost no damage. Spectroscopic characterization (EDX, XPS, FTIR) found clear indications of oxidation and chlorine abstraction for parylene C aged in vivo . While in vitro aging was also accompanied by signs of oxidation, changes in the chemistry in vivo and in vitro were statistically different. Analysis of RAA- aged devices identified UEA fabrication approaches that may greatly improve device resistance to degradation. This work underscores the need for an improved understanding of in vivo damage mechanisms, to facilitate the critical need for representative in vitro accelerated testing paradigms for long-term implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Wodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Cited by
Explant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“The main concerns in the use of polymer-based implants are related to device encapsulation and longterm reliability and stability [207], and delamination within themultilayer structure that may be promoted by the wet and ionic environment of the body.”
BackgroundPatel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
Lamont, C., Grego, T., Nanbakhsh, K., Shah Idil, A., Giagka, V, Vanhoestenberghe, A., Cogan, S., & Donaldson, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf0d6 · Cited by 28
Metadata
- Authors
- Caldwell, R., Street, M. G., Sharma, R., Takmakov, P., Baker, B., & Rieth, L.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 232
- Pages
- 119731
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2997804659
- Cited by
- 100
- References
- 26
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation. https://app.cochat.ai/papers/10.1016/j.biomaterials.2019.119731
- The paper
- Caldwell, R., Street, M. G., Sharma, R., Takmakov, P., Baker, B., & Rieth, L. (2020). Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation. Biomaterials. https://doi.org/10.1016/j.biomaterials.2019.119731
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.