Ten-dimensional anthropomorphic arm control in a human brain−machine interface: difficulties, solutions, and limitations
Open accessAbstract
OBJECTIVE: In a previous study we demonstrated continuous translation, orientation and one-dimensional grasping control of a prosthetic limb (seven degrees of freedom) by a human subject with tetraplegia using a brain-machine interface (BMI). The current study, in the same subject, immediately followed the previous work and expanded the scope of the control signal by also extracting hand-shape commands from the two 96-channel intracortical electrode arrays implanted in the subject's left motor cortex. APPROACH: Four new control signals, dictating prosthetic hand shape, replaced the one-dimensional grasping in the previous study, allowing the subject to control the prosthetic limb with ten degrees of freedom (three-dimensional (3D) translation, 3D orientation, four-dimensional hand shaping) simultaneously. MAIN RESULTS: Robust neural tuning to hand shaping was found, leading to ten-dimensional (10D) performance well above chance levels in all tests. Neural unit preferred directions were broadly distributed through the 10D space, with the majority of units significantly tuned to all ten dimensions, instead of being restricted to isolated domains (e.g. translation, orientation or hand shape). The addition of hand shaping emphasized object-interaction behavior. A fundamental component of BMIs is the calibration used to associate neural activity to intended movement. We found that the presence of an object during calibration enhanced successful shaping of the prosthetic hand as it closed around the object during grasping. SIGNIFICANCE: Our results show that individual motor cortical neurons encode many parameters of movement, that object interaction is an important factor when extracting these signals, and that high-dimensional operation of prosthetic devices can be achieved with simple decoding algorithms. ClinicalTrials.gov Identifier: NCT01364480.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone.
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
From A brain-computer interface that evokes tactile sensations improves robotic arm control (2021) · cites this paper as [5]
Section 3.4 reports similar functional-task scores under 7D and 10D control, but both scores are from the same participant. Section 2.2 identifies a single participant; this paper therefore does not establish the claim about two participants achieving similar scores with vision alone. Page numbers are unavailable in our copy. (LLM, conf=0.88)
Experimental — accuracy not yet measuredICMS can deliver localized tactile percepts with natural features and can be used in human-brain-computer interface applications for better control using area S1.
“ICMS can also be employed to deliver localized tactile percepts with natural features as well as in human-brain-computer interface applications for better control using area S1 (Collinger et al., 2013; Wodlinger et al., 2015; Downey et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Wodlinger et al., 2015
The Abstract reports brain–machine-interface control of a prosthetic arm, supporting the general application to human interface control. But §2.2 (Participant) places the recording arrays in motor cortex, not S1; the paper does not report ICMS, localized tactile percepts, or natural tactile features. Page numbers were not supplied for these passages. (LLM, conf=0.88)
Experimental — accuracy not yet measuredBy combining improvements in bionic arms and decoding algorithms, it is now possible for a human patient to perform tasks with a bionic arm by thoughts alone.
“By combining these innovations, it is now possible for a human patient to perform tasks with a bionic arm by thoughts alone (Collinger et al., 2013; Wodlinger et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Wodlinger et al., 2015
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,187 · see citing works
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.2307/1267205 · Cited by 2,284 · see citing works
Adult Norms for the Box and Block Test of Manual Dexterity
Mathiowetz, V. G., Volland, G., Kashman, N., & Weber, K. (1985) · American Journal of Occupational Therapy · doi:10.5014/ajot.39.6.386 · Cited by 2,105 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · see citing works
Self-citationLyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,335 · see citing works
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215 · see citing works
(1950) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1950.04040020187020 · Cited by 1,108 · see citing works
Variable impedance actuators: A review
Vanderborght, B., Albu‐Schäffer, A., Bicchi, A., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M. G., Eiberger, O., Friedl, W., Ganesh, G., et al. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.06.009 · Cited by 1,010 · see citing works
Shirazi, S. F. S., Gharehkhani, S., Mehrali, M., Yarmand, H., Metselaar, H. S. C., Kadri, N. A., & Osman, N. A. A. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/3/033502 · Cited by 757 · see citing works
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496 · see citing works
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485 · see citing works
Control strategies in object manipulation tasks
Flanagan, J. R., Bowman, M. C., & Johansson, R. S. (2006) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2006.10.005 · Cited by 442 · see citing works
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler‐Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 396 · see citing works
Self-citationHand Synergies During Reach-to-Grasp
Mason, C. R., Gomez, J. E., & Ebner, T. J. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.6.2896 · Cited by 353 · see citing works
Scavarda, A. (1984) · Military Medicine · doi:10.1093/milmed/149.2.72a · Cited by 298 · see citing works
Congruent Activity during Action and Action Observation in Motor Cortex
Tkach, D. C., Reimer, J., & Hatsopoulos, N. G. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.2895-07.2007 · Cited by 292 · see citing works
Analysis of the synergies underlying complex hand manipulation
Todorov, E. V., & Zoubin Ghahramani, A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404285 · Cited by 181 · see citing works
Motor Cortical Representation of Position and Velocity During Reaching
Wang, W., Chan, S. S., Heldman, D. A., & Moran, D. W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01180.2006 · Cited by 145 · see citing works
Chase, S. M., Schwartz, A. B., & Kass, R. E. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.05.005 · Cited by 135 · see citing works
Self-citationChase, S. M., Kass, R. E., & Schwartz, A. B. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00371.2011 · Cited by 127 · see citing works
Self-citationWang, W., Degenhart, A. D., Collinger, J. L., Vinjamuri, R. K., Sudre, G. P., Adelson, P. D., Holder, D. L., Leuthardt, E. C., Moran, D. W., Boninger, M. L., et al. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333704 · Cited by 118 · see citing works
Self-citationAsynchronous Decoding of Dexterous Finger Movements Using M1 Neurons
Aggarwal, V., Acharya, S., Tenore, F. V., Shin, H., Etienne‐Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916289 · Cited by 99 · see citing works
Tangible nanocomposites with diverse properties for heart valve application
Vellayappan, M. V., Balaji, A., Subramanian, A. P., et al. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/3/033504 · Cited by 92 · see citing works
Decoding M1 Neurons During Multiple Finger Movements
Hamed, S. B., Schieber, M. H., & Pouget, A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00760.2006 · Cited by 82 · see citing works
Reassembly of S-layer proteins
Pum, D., & Sleytr, U. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/31/312001 · Cited by 67 · see citing works
Observation-based learning for brain–machine interfaces
Tkach, D. C., Reimer, J., & Hatsopoulos, N. G. (2008) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2008.09.016 · Cited by 54 · see citing works
Neural Decoding of Finger Movements Using Skellam-Based Maximum-Likelihood Decoding
Shin, H., Aggarwal, V., Acharya, S., Schieber, M. H., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2020791 · Cited by 50 · see citing works
Neural prosthetic systems: Current problems and future directions
Chestek, C. A., Cunningham, J. P., Gilja, V., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332822 · Cited by 47 · see citing works
Toward Synergy-Based Brain-Machine Interfaces
Vinjamuri, R. K., Weber, D. J., Mao, Z., Collinger, J. L., Degenhart, A. D., Kelly, J. W., Boninger, M. L., Tyler‐Kabara, E. C., & Wang, W. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2160272 · Cited by 39 · see citing works
Self-citationEffects of Object Compliance on Three-Digit Grasping
Winges, S. A., Eonta, S. E., Soechting, J. F., et al. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91021.2008 · Cited by 29 · see citing works
Electroactive biocompatible materials for nerve cell stimulation
Yang, M., Liang, Y., Gui, Q., Chen, J., & Liu, Y. (2015) · Materials Research Express · doi:10.1088/2053-1591/2/4/042001 · Cited by 28 · see citing works
Decoding grasp aperture from motor-cortical population activity
Artemiadis, P., Shakhnarovich, G., Vargas-Irwin, C. E., Donoghue, J. P., & Black, M. J. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369723 · Cited by 23 · see citing works
Multidigit Control of Contact Forces During Transport of Handheld Objects
Winges, S. A., Soechting, J. F., & Flanders, M. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00267.2007 · Cited by 22 · see citing works
Neuroprosthetic control and tetraplegia – Authors'reply
Boninger, M. L., Mitchell, G. W., Tyler‐Kabara, E. C., Collinger, J. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(13)61154-x · Cited by 10 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704 · see citing works
Self-citationA brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617 · see citing works
Self-citationBenabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404 · see citing works
Noninvasive neuroimaging enhances continuous neural tracking for robotic device control
Edelman, B. J., Meng, J., Suma, D., Zurn, C., Nagarajan, E., Baxter, B. S., Cline, C. C., & He, B. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6844 · Cited by 380 · see citing works
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314 · see citing works
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263 · see citing works
An Accurate and Rapidly Calibrating Speech Neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2314132 · Cited by 238 · see citing works
Degenhart, A. D., Bishop, W. E., Oby, E. R., Tyler-Kabara, E. C., Chase, S. M., Batista, A. P., & Yu, B. M. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0542-9 · Cited by 212 · see citing works
Self-citationHotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201 · see citing works
A review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192 · see citing works
Biomimetic approaches to bionic touch through a peripheral nerve interface
Saal, H. P., & Bensmaia, S. J. (2015) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2015.06.010 · Cited by 179 · see citing works
“Major strides have been made in the development of approaches to control these hands either by decoding motor intent from myoelectric signals (Fougner et al., 2012; Schultz and Kuiken, 2011) or from the activation of neurons in motor cortex (Bensmaia and Miller, 2014; Wodlinger et al., 2015).”
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165 · see citing works
Intracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149 · see citing works
Self-citationClinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135 · see citing works
Plug-and-play control of a brain–computer interface through neural map stabilization
Silversmith, D. B., Abiri, R., Hardy, N. F., Natraj, N., Tu-Chan, A., Chang, E. F., & Ganguly, K. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0662-5 · Cited by 126 · see citing works
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113 · see citing works
Decoding spoken English from intracortical electrode arrays in dorsal precentral gyrus
Wilson, G. H., Stavisky, S. D., Willett, F. R., Avansino, D. T., Kelemen, J. N., Hochberg, L. R., Henderson, J. M., Druckmann, S., & Shenoy, K. V. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbfef · Cited by 103 · see citing works
Downey, J. E., Weiss, J. M., Muelling, K., Venkatraman, A., Valois, J.-S., Hebert, M., Bagnell, J. A., Schwartz, A. B., & Collinger, J. L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0134-9 · Cited by 111 · see citing works
Self-citationSelectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“ICMS can also be employed to deliver localized tactile percepts with natural features as well as in human-braincomputer interface applications for better control using area S1 (Collinger et al., 2013; Wodlinger et al., 2015; Downey et al., 2016).”
InfluentialExplant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90 · see citing works
Self-citationRobust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69 · see citing works
Motor cortical activity changes during neuroprosthetic-controlled object interaction
Downey, J. E., Brane, L., Gaunt, R. A., Tyler-Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-17222-3 · Cited by 63 · see citing works
Self-citationBullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65 · see citing works
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65 · see citing works
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
Hiremath, S. V., Chen, W., Wang, W., Foldes, S., Yang, Y., Tyler-Kabara, E. C., Collinger, J. L., & Boninger, M. L. (2015) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2015.00040 · Cited by 53 · see citing works
Self-citationSystems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45 · see citing works
Pennartz, C. M. A. (2022) · Behavioural Brain Research · doi:10.1016/j.bbr.2022.113969 · Cited by 40 · see citing works
Stabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K., Ma, X., Miller, L. E., & Pandarinath, C. (2022) · doi:10.1101/2022.04.06.487388 · Cited by 71 · see citing works
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25 · see citing works
Speech-related dorsal motor cortex activity does not interfere with iBCI cursor control
Stavisky, S. D., Willett, F. R., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5b72 · Cited by 25 · see citing works
An accurate and rapidly calibrating speech neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2023) · doi:10.1101/2023.12.26.23300110 · Cited by 244 · see citing works
- Authors
- Wodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L.
- Affiliations
- University of Pittsburgh (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-12-16
- Volume
- 12
- Issue
- 1
- Pages
- 016011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2033144847
- Cited by
- 536
- References
- 36
- Citations by year
- 2026: 27 · 2025: 52 · 2024: 45 · 2023: 57 · 2022: 45 · 2021: 57 · 2020: 50 · 2019: 45 · 2018: 41 · 2017: 51 · 2016: 45 · 2015: 20 · 2013: 1
- FWCI
- 21.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Veterans Affairs (B6789C, B7143R, and RX720)
- Defense Advanced Research Projects Agency (contract number N66001-10-C-4056)
- UPMC Rehabilitation Institute
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, intracortical electrodes, motor cortex, prosthetic hand control, grasping, tetraplegia, neural tuning, object interaction, calibration
- MeSH terms
- Adult, Arm, Artificial Limbs, Computer Simulation, Electroencephalography, Female, Humans, Imagination, Joints, Models, Biological, Prosthesis Design, Quadriplegia, Robotics, Evoked Potentials, Motor, Equipment Failure Analysis, Feedback, Physiological, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review