The DOI matches its Crossref record; 271 of the 274 references it cites were found in a registry or an index.
Wearable and implantable devices for drug delivery: Applications and challenges
Abstract
Poor adherence to drug dosing schedule is responsible for ∼50% of hospitalization cases. Most patients fail to adhere to a strict dosing schedule due to invasive drug administration, off-target toxicities, or medical conditions like dementia. The emerging concept of wearable devices (WDs), implantable devices (IDs) and combined wearable and implantable devices (WIDs) for drug delivery has created new opportunities for treating patients with chronic diseases needing repeated and long-term medical attention like diabetes, ocular disorders, cancer, wound healing, cardiovascular diseases, and contraception. WDs, worn on the body surface have created appealing non-invasive, self-administrable drug delivery platforms which receive huge patient compliance. Microneedle-skin patches, wound healing patches, drug-eluting contact lenses, mouth guards, intra-vaginal rings, pharmaceutical jewelry, and drug-loaded self-care textiles are popular WDs explored in drug delivery. In contrast, IDs are surgically placed inside body tissue allowing higher payload and enhanced localized effect for an extended duration. Hormone micropumps, hydrogel/nanofibrous depot, coronary stents, intravitreal devices, and intrauterine devices are some representative examples of IDs. In this review, we have described the past 10 years of research progress on drug-delivering WDs and IDs in the context of treating diseases that demand repeated and long-term medication, especially those affecting soft tissues. We highlighted several technical challenges that need to be addressed before considering the translation of such technologies to clinics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These devices have been used to deliver a range of therapeutic agents, including polypeptides, polysaccharides, small molecules, and growth factors, continuously and responsively (Kar et al. 2022; Yang, Yuan et al. 2022a; Yang, Yuan et al. 2022b).”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Kar et al. 2022
Citations
Cites
Osterberg, L., & Blaschke, T. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050100 · Cited by 7,974
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
Franz, S., Rammelt, S., Scharnweber, D., & Simon, J. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.078 · Cited by 1,391
Microneedles: A smart approach and increasing potential for transdermal drug delivery system
Waghule, T., Singhvi, G., Dubey, S. K., Pandey, M. M., Gupta, G., Singh, M., & Dua, K. (2018) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.10.078 · Cited by 1,277
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Advanced materials and processing for drug delivery: The past and the future
Zhang, Y., Chan, H. F., & Leong, K. W. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.003 · Cited by 1,008
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Research works printed but not linked: 7
- 2011, vol. 86, 304
- Bonadies, 2017, vol. 72
- Qiao, 2017, vol. 28, 149
- Pons-Faudoa, 2019, Advanced implantable drug delivery technologies: transforming the clinical landscape of therapeutics for chronic diseases, Biomed. Microdevices, 21, 1, 10.1007/s10544-019-0389-6 · DOI
- Yang, 2020, E-jet 3D printed drug delivery implants to inhibit growth and metastasis of orthotopic breast cancer, Biomaterials, 230
- Gao, 2014, vol. 853, 101
- Iqbal, 2013, Coronary stents: historical development, current status and future directions, Br. Med. Bull., 106, 193, 10.1093/bmb/ldt009 · DOI
Cited by
Sorted by citations
Wang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Flexible and Stretchable Light-Emitting Diodes and Photodetectors for Human-Centric Optoelectronics
Chang, S., Koo, J. H., Yoo, J., Kim, M. S., Choi, M. K., Kim, D., & Song, Y. M. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00548 · Cited by 218
Xiang, Y., Lu, J., Mao, C., Zhu, Y., Wang, C., Wu, J., Liu, X., Wu, S., Kwan, K. Y.-H., Cheung, K., et al. (2023) · Science Advances · doi:10.1126/sciadv.adf0854 · Cited by 192
Digital health: trends, opportunities and challenges in medical devices, pharma and bio-technology
Kasoju, N., Remya, N. S., Sasi, R., Sreedharan, S., Soman, B., Kesavadas, C., Muraleedharan, C. V., Varma, P. R. H., & Behari, S. (2023) · CSI Transactions on ICT · doi:10.1007/s40012-023-00380-3 · Cited by 197
Kumarasamy, R. V., Natarajan, P. M., Umapathy, V. R., Roy, J. R., Mironescu, M., & Palanisamy, C. P. (2024) · Frontiers in Nanotechnology · doi:10.3389/fnano.2024.1479993 · Cited by 154
Metadata
- Authors
- Kar, A., Ahamad, N., Dewani, M., Awasthi, L., Patil, R., & Banerjee, R.
- Affiliations
- Indian Institute of Technology Bombay (IN)
- Corresponding author
- Ahamad, Nadim
- Banerjee, Rinti
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2022-04
- Volume
- 283
- Pages
- 121435
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W4214555582
- Cited by
- 179
- References
- 274
- Citations by year
- 2026: 36 · 2025: 53 · 2024: 42 · 2023: 39 · 2022: 9
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Ministry of Education, India
- Department of Biotechnology, Ministry of Science and Technology, India
- Indian Institute of Technology Bombay (20001208)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- implantable drug delivery, medication adherence, drug-eluting contact lenses, coronary stents, intrauterine devices, chronic disease treatment, non-invasive drug delivery
- MeSH terms
- Wearable Electronic Devices, Diabetes Mellitus, Pharmaceutical Preparations, Female, Humans, Drug Delivery Systems, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review