The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Label-free detection of Staphylococcus aureus in skin using real-time potentiometric biosensors based on carbon nanotubes and aptamers
Open accessAbstract
In this paper we report the first biosensor that is able to detect Staphylococcus aureus in real-time. A network of single-walled carbon nanotubes (SWCNTs) acts as an ion-to-electron potentiometric transducer and anti-S. aureus aptamers are the recognition element. Carbon nanotubes were functionalized with aptamers using two different approaches: (1) non-covalent adsorption of drop-casted pyrenil-modified aptamers onto the external walls of the SWCNTs; and (2) covalent bond formation between amine-modified aptamers and carboxylic groups previously introduced by oxidation at the ends of the SWCNTs. Both of these approaches yielded functional biosensors but there were large differences in the minimum detectable bacteria concentration and sensitivity values. With covalent functionalization, the minimum concentration detected was 8×10(2)colony-forming units (CFU)/mL and the sensitivity was 0.36 mV/Decade. With the non-covalent approach, the sensitivity was higher (1.52 mV/Decade) but the minimum concentration detected was greatly affected (10(7) CFU/mL). In both cases, potential as a function of Decade of bacteria concentration was linear. Functional biosensors were used to test real samples from freshly excised pig skin, contaminated with the target microorganism, as a surrogate for human skin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hidron, A. I., Edwards, J. R., Patel, J., Horan, T. C., Sievert, D. M., Pollock, D. A., Fridkin, S. K., & National Healthcare Safety Network Team and Participating National Healthcare Safety Network Facilities (2008) · Infection Control & Hospital Epidemiology · doi:10.1086/591861 · Cited by 3,724
Waves of resistance: Staphylococcus aureus in the antibiotic era
Chambers, H. F., & DeLeo, F. R. (2009) · Nature Reviews Microbiology · doi:10.1038/nrmicro2200 · Cited by 2,718
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
David, M. Z., & Daum, R. S. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00081-09 · Cited by 1,972
Meyer, W., Schwarz, R., & Neurand, K. (2015) · Current Problems in Dermatology · doi:10.1159/000401274 · Cited by 454
Cited by
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Biosensors for Whole-Cell Bacterial Detection
Ahmed, A., Rushworth, J. V., Hirst, N. A., & Millner, P. A. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00120-13 · Cited by 666
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Advances in Antimicrobial Microneedle Patches for Combating Infections
Jamaledin, R., Yiu, C. K. Y., Zare, E. N., Niu, L., Vecchione, R., Chen, G., Gu, Z., Tay, F. R., & Makvandi, P. (2020) · Advanced Materials · doi:10.1002/adma.202002129 · Cited by 461
Metadata
- Authors
- Zelada-Guillén, G. A., Sebastián-Avila, J. L., Blondeau, P., Riu, J., & Rius, F. X.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 31
- Issue
- 1
- Pages
- 226-232
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2002312122
- Cited by
- 207
- References
- 5
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.