The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
A simple and compact smartphone accessory for quantitative chemiluminescence-based lateral flow immunoassay for salivary cortisol detection
Open accessAbstract
We have developed a simple and accurate biosensor based on a chemiluminescent (CL)-lateral flow immunoassay (LFIA) method integrated in a smartphone to quantitatively detect salivary cortisol. The biosensor is based on a direct competitive immunoassay using peroxidase-cortisol conjugate, detected by adding the chemiluminescent substrate luminol/enhancer/hydrogen peroxide. The smartphone camera is used as light detector, for image acquisition and data handling via a specific application. We 3D-printed simple accessories to adapt the smartphone. The system comprises a cartridge, which houses the LFIA strip, and a smartphone adaptor with a plano-convex lens and a cartridge-insertion slot. This provides a mini-darkbox and aligned optical interface between the camera and the LFIA membrane for acquiring CL signals. The method is simple and fast, with a detection limit of 0.3 ng/mL. It provides quantitative analysis in the range of 0.3-60 ng/mL, which is adequate for detecting salivary cortisol in the clinically accepted range. It could thus find application in the growing area of home-self-diagnostic device technology for clinical biomarker monitoring, overcoming the current difficulties in achieving sensitive and quantitative information with conventional systems taking the advantage of smartphone connectivity and the enhanced performance of the included camera.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2009) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,720
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Posthuma‐Trumpie, G. A., Korf, J., & van Amerongen, A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,588
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,445
The Smartphone in Medicine: A Review of Current and Potential Use Among Physicians and Students
Ozdalga, E., Ozdalga, A., & Ahuja, N. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1994 · Cited by 654
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 426
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Özcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40864c · Cited by 365
Zhao, W., & van den Berg, A. (2008) · Lab on a Chip · doi:10.1039/b814043j · Cited by 237
Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast
Qin, Z., Chan, W. C. W., Boulware, D. R., Akkin, T., Butler, E. K., & Bischof, J. C. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200997 · Cited by 221
Flagged first, then by citations
Research works printed but not linked: 2
- Pires, 2014, Biomed. Mater. Eng., 24, 15
- Swain, 2008, Photon Spectra, 42, 46
Cited by
Sorted by citations
Items 101–200 of 373
Zhang, J., Shen, Z., Xiang, Y., & Lu, Y. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00270 · Cited by 65
A smartphone-based biomedical sensory system
Zhao, W., Tian, S., Huang, L., Liu, K., Dong, L., & Guo, J. (2020) · The Analyst · doi:10.1039/c9an02294e · Cited by 63
Khan, M. S., Dighe, K., Wang, Z., Srivastava, I., Schwartz‐Duval, A. S., Misra, S. K., & Pan, D. (2018) · The Analyst · doi:10.1039/c8an02085j · Cited by 63
Klinghammer, S., Voitsekhivska, T., Licciardello, N., Kim, K., Baek, C.-K., Cho, H., Wolter, K.-J., Kirschbaum, C., Baraban, L., & Cuniberti, G. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02267 · Cited by 62
Kim, K., Han, K. N., Choi, N., Kim, S. H., Joung, Y., Kim, K., Ho, N. T., Joo, S., & Choo, J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c05336 · Cited by 62
Strategies in liquid-phase chemiluminescence and their applications in bioassay
Su, Y., Deng, D., Zhang, L., Song, H., & Lv, Y. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.07.002 · Cited by 62
Nano-Biosensing Platforms for Detection of Cow’s Milk Allergens: An Overview
Nehra, M., Lettieri, M., Dilbaghi, N., Kumar, S., & Marrazza, G. (2019) · Sensors · doi:10.3390/s20010032 · Cited by 61
3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia
Plevniak, K., Campbell, M., Myers, T., Hodges, A. M., & He, M. (2016) · Biomicrofluidics · doi:10.1063/1.4964499 · Cited by 60
Algorithms for immunochromatographic assay: review and impact on future application
Qin, Q., Wang, K., Yang, J., Xu, H., Cao, B., Wo, Y., Jin, Q., & Cui, D. (2019) · The Analyst · doi:10.1039/c9an00964g · Cited by 60
Kim, H. S., Kim, H. J., Lee, J., Lee, T., Yun, J., Lee, G., & Hong, Y. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02496 · Cited by 59
Cortisol Immunosensors: A Literature Review
Karachaliou, C., Koukouvinos, G., Goustouridis, D., Raptis, I., Kakabakos, S. E., Petrou, P. S., & Livaniou, E. (2023) · Biosensors · doi:10.3390/bios13020285 · Cited by 63
Lin, B., Guan, Z., Song, Y., Song, E., Lu, Z., Liu, D., An, Y., Zhu, Z., Zhou, L., & Yang, C. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00010g · Cited by 59
Green and equitable analytical chemistry
Marcinkowska, R., Namieśnik, J., & Tobiszewski, M. (2019) · Current Opinion in Green and Sustainable Chemistry · doi:10.1016/j.cogsc.2019.04.003 · Cited by 60
Shirtcliff, E. A., Buck, R. L., Laughlin, M. J., Hart, T., Cole, C. R., & Slowey, P. D. (2015) · Clinical Therapeutics · doi:10.1016/j.clinthera.2015.02.014 · Cited by 61
Seo, S.-M., Kim, S., Jeon, J.-W., Kim, J., Kim, H.-S., Cho, J., Lee, W., & Paek, S. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.061 · Cited by 57
Bock, S., Kim, H., Kim, J., An, J., Choi, Y.-S., Pham, X., Jo, A., Ham, K.-M., Song, H., Kim, J.-W., et al. (2021) · Nanomaterials · doi:10.3390/nano12010033 · Cited by 58
Zangheri, M., Nardo, F. D., Mirasoli, M., Anfossi, L., Nascetti, A., Caputo, D., de Cesare, G., Guardigli, M., Baggiani, C., & Roda, A. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9991-0 · Cited by 56
Self-citationMin, H. J., Mina, H. A., Deering, A. J., & Bae, E. (2021) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2021.106288 · Cited by 55
Chen, X., Yuan, N., Pan, S., Liu, B., Chang, Y., Pang, W., & Duan, X. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00602 · Cited by 53
Methods in Raman spectroscopy for saliva studies – a review
Hardy, M., Kelleher, L., Gomes, P. D. C., Buchan, E., Chu, H. O., & Oppenheimer, P. G. (2021) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2021.1969944 · Cited by 56
Pandit, P., Crewther, B. T., Cook, C. J., Punyadeera, C., & Pandey, A. K. (2024) · Materials Advances · doi:10.1039/d3ma00937h · Cited by 60
Liang, R.-L., Xu, X.-P., Liu, T., Zhou, J., Wang, X., Ren, Z., Hao, F., & Wu, Y. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.07.053 · Cited by 54
dos Santos, V. I., Chevalier, J., Fredel, M. C., Henriques, B. A. P. D. C., & Grémillard, L. (2024) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2024.100841 · Cited by 53
Hou, L., Wu, X., Chen, G., Yang, H., Lu, M., & Tang, D. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.01.043 · Cited by 53
Salivary markers of kidney function — Potentials and limitations
Celec, P., Tóthová, Ľ., Šebeková, K., Podracká, Ľ., & Boor, P. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.11.028 · Cited by 53
Qin, W., Wang, K., Xiao, K., Hou, Y., Lu, W., Xu, H., Wo, Y., Feng, S., & Cui, D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.052 · Cited by 53
Moving toward smart biomedical sensing
Naghdi, T., Ardalan, S., Adib, Z. A., Sharifi, A. R., & Golmohammadi, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.115009 · Cited by 52
Paper-based sensors for rapid important biomarkers detection
Kuswandi, B., Hidayat, M. A., & Noviana, E. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100246 · Cited by 50
Fu, Q., Wu, Z., Xu, F., Li, X., Yao, C., Xu, M., Sheng, L., Yu, S., & Tang, Y. (2016) · Lab on a Chip · doi:10.1039/c6lc00083e · Cited by 50
Development of ultra-low volume, multi-bio fluid, cortisol sensing platform
Upasham, S., Tanak, A., Jagannath, B., & Prasad, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-35199-5 · Cited by 50
Li, F., Zhao, A., Li, Z., Xi, Y., Jiang, J., He, J., Wang, J., & Cui, H. L. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05434 · Cited by 49
Lebiga, E., Fernandez, R. E., & Beşkök, A. (2015) · The Analyst · doi:10.1039/c5an00720h · Cited by 49
Shining light on biosensors: Chemiluminescence and bioluminescence in enabling technologies
Roda, B., Deo, S. K., O’Connor, G., Moraskie, M., Giordani, S., Marassi, V., Roda, A., & Daunert, S. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117975 · Cited by 48
Self-citationKim, H. T., Jin, E., & Lee, M. (2021) · Biosensors · doi:10.3390/bios11060191 · Cited by 49
Jain, S., Paliwal, A., Gupta, V., & Tomar, M. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113919 · Cited by 47
Roda, A., Zangheri, M., Calabria, D., Mirasoli, M., Caliceti, C., Quintavalla, A., Lombardo, M., Trombini, C., & Simoni, P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.012 · Cited by 46
Self-citationFingerprints mapping and biochemical sensing on smartphone by electrochemiluminescence
Li, S., Lu, Y., Liu, L., Low, S. S., Su, B., Wu, J., Zhu, L., Li, C., & Liu, Q. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.035 · Cited by 47
Novel versatile smart phone based Microplate readers for on-site diagnoses
Fu, Q., Wu, Z., Li, X., Yao, C., Yu, S., Xiao, W., & Tang, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.03.049 · Cited by 46
A review of smartphone point‐of‐care adapter design
Alawsi, T., & Mahdi, Z. F. (2019) · Engineering Reports · doi:10.1002/eng2.12039 · Cited by 46
Pham, A. T. T., Wallace, A. K., Zhang, X., Tohl, D., Fu, H., Chuah, C., Reynolds, K. J., Ramsey, C., & Tang, Y. (2021) · Diagnostics · doi:10.3390/diagnostics11071285 · Cited by 45
Mobile phone based ELISA (MELISA)
Zhdanov, A., Keefe, J., Franco-Waite, L., Konnaiyan, K. R., & Pyayt, A. L. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.12.033 · Cited by 44
Oh, H.-K., Kim, J., Kim, J., & Kim, M. (2018) · The Analyst · doi:10.1039/c8an00719e · Cited by 45
Analytical aspects of smart (phone) fluorometric measurements
Granica, M., & Tymecki, Ł. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.032 · Cited by 45
Hutchison, J. R., Erikson, R. L., Sheen, A. M., Ozanich, R. M., & Kelly, R. (2015) · The Analyst · doi:10.1039/c5an01304f · Cited by 44
Fang, J., Qiu, X., Wan, Z., Zou, Q., Su, K., Hu, N., & Wang, P. (2016) · Analytical Methods · doi:10.1039/c6ay01384h · Cited by 44
Biosensors for psychiatric biomarkers in mental health monitoring
Wang, L., Hu, Y., Jiang, N., & Yetisen, A. K. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116242 · Cited by 50
Chen, T., Sun, C., Abbas, S. C., Alam, N., Qiang, S., Tian, X., Fu, C., Zhang, H., Xia, Y., Liu, L., et al. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342877 · Cited by 46
Nanoparticle-based photoacoustic analysis for highly sensitive lateral flow assays
Zhao, Y., Huang, Y., Zhao, X., McClelland, J. F., & Lu, M. (2016) · Nanoscale · doi:10.1039/c6nr05312b · Cited by 43
Wang, R., Ongagna-Yhombi, S. Y., Lu, Z., Centeno‐Tablante, E., Colt, S., Cao, X. E., Ren, Y., Cardenas, W. B., Mehta, S., & Erickson, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00704 · Cited by 43
Technologies for Frugal and Sensitive Point-of-Care Immunoassays
Kinnamon, D., Heggestad, J. T., Liu, J., & Chilkoti, A. (2022) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061020-123817 · Cited by 44
Singhal, C. M., Kaushik, V., Awasthi, A., Zalke, J. B., Palekar, S. D., Rewatkar, P., Srivastava, S. K., Kulkarni, M. B., & Bhaiyya, M. L. (2025) · Bioengineering · doi:10.3390/bioengineering12020119 · Cited by 43
Misbah, I., Zhao, F., & Shih, W. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17876 · Cited by 42
Accessible Telemedicine Diagnostics with ELISA in a 3D Printed Pipette Tip
Sharafeldin, M., Kadimisetty, K., Bhalerao, K. S., Bist, I., Jones, A. L., Chen, T., Lee, N. H., & Rusling, J. F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01284 · Cited by 42
Wang, Q., Song, H., Zhu, A., & Qiu, F. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3039627 · Cited by 42
Xiong, S., Zhou, Y., Huang, X., Yu, R., Lai, W., & Xiong, Y. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.039 · Cited by 41
Wireless and mobile optical chemical sensors and biosensors
Kassal, P., Horak, E., Sigurnjak, M., Steinberg, M. D., & Steinberg, I. M. (2018) · Reviews in Analytical Chemistry · doi:10.1515/revac-2017-0024 · Cited by 42
Electrochemical Aptamer-Based Biosensors for Measurements in Undiluted Human Saliva
Nguyen, M., Nguyen, K.-N., Malo, S., Banerjee, I., Wu, D., Du‐Thumm, L., & Dauphin‐Ducharme, P. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01624 · Cited by 40
Smartphone based colorimetric approach for quantitative determination of uric acid using Image J
Elagamy, S. H., Adly, L., & Hamid, M. A. A. (2023) · Scientific Reports · doi:10.1038/s41598-023-48962-0 · Cited by 40
Zhao, Y., Wei, Y., Ye, C., Cao, J., Zhou, X., Xie, M., Qing, J., & Chen, Z. (2024) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2024.1475922 · Cited by 40
Zhang, T., Wang, H., Zhong, Z., Li, C.-Q., Chen, W., Liu, B., & Zhao, Y. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105038 · Cited by 40
Smartphone based lateral flow immunoassay quantifications
Park, J. (2024) · Journal of Immunological Methods · doi:10.1016/j.jim.2024.113745 · Cited by 39
A smartphone‐based on‐site nucleic acid testing platform at point‐of‐care settings
Xu, X., Wang, X., Hu, J., Gong, Y., Wang, L., Zhou, W., Li, X., & Xu, F. (2018) · Electrophoresis · doi:10.1002/elps.201800449 · Cited by 39
Low-cost Point-of-Care Biosensors Using Common Electronic Components as Transducers
Han, Y. D., Chun, H. J., & Yoon, H. C. (2020) · BioChip Journal · doi:10.1007/s13206-020-4104-8 · Cited by 38
Fu, H.-J., Yuan, L.-P., Shen, Y., Liu, Y., Liu, B., Zhang, S., Xie, Z.-X., Lei, H., Sun, Y., & Xu, Z. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.06.015 · Cited by 38
Ambulatory measurement of cortisol: Where do we stand, and which way to follow?
Hogenelst, K., Soeter, M., & Kallen, V. (2018) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2018.100249 · Cited by 38
Su, K., Pan, Y., Wan, Z., Zhong, L., Fang, J., Zou, Q., Li, H., & Wang, P. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.04.036 · Cited by 37
Shin, J., Kim, S., Yoon, T., Joo, C., & Jung, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.046 · Cited by 38
Paper-based immunosensor with competitive assay for cortisol detection
Apilux, A., Rengpipat, S., Suwanjang, W., & Chailapakul, O. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112925 · Cited by 37
Pohanka, M. (2015) · Sensors · doi:10.3390/s150613752 · Cited by 36
Calabretta, M. M., Zangheri, M., Lopreside, A., Marchegiani, E., Montali, L., Simoni, P., & Roda, A. (2020) · The Analyst · doi:10.1039/c9an02041a · Cited by 38
Self-citationSensing of body fluid hormones using paper-based analytical devices
Kelkar, N., Prabhu, A., Prabhu, A., Nandagopal, M. S. G., & Mani, N. K. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.107069 · Cited by 36
Paper-based optical sensors paired with smartphones for biomedical analysis
Karim, K., Lamaoui, A., & Amine, A. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.115207 · Cited by 36
Sensors as green tools in analytical chemistry
del Valle, M. (2021) · Current Opinion in Green and Sustainable Chemistry · doi:10.1016/j.cogsc.2021.100501 · Cited by 35
Cai, P., Wang, R., Ling, S., & Wang, S. (2021) · Food Chemistry · doi:10.1016/j.foodchem.2021.130021 · Cited by 35
Su, K., Qiu, X., Fang, J., Zou, Q., & Wang, P. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.092 · Cited by 35
Developing Gold Nanoparticles-Conjugated Aflatoxin B1 Antifungal Strips
Sojinrin, T., Liu, K., Wang, K., Cui, D., Byrne, H. J., Curtin, J. F., & Tian, F. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20246260 · Cited by 34
Recent Progress in Long-Term Sleep Monitoring Technology
Yin, J., Xu, J., & Ren, T. (2023) · Biosensors · doi:10.3390/bios13030395 · Cited by 36
Lateral flow immunoassay for proteins
Nan, X., Li, Y., & Cui, Y. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117337 · Cited by 33
Smartphone schlieren and shadowgraph imaging
Settles, G. S. (2017) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2017.07.002 · Cited by 35
Yuan, H., Chen, P., Wan, C., Li, Y., & Liu, B. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116814 · Cited by 35
Small camera as a handheld colorimetric tool in the analytical chemistry
Pohanka, M. (2017) · Chemical Papers · doi:10.1007/s11696-017-0166-z · Cited by 32
Xu, Y., Yang, H.-W., Huang, Z., Li, Y., He, Q., Tu, Z., Ji, Y., & Ren, W. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.06.096 · Cited by 32
Ways to Reach Lower Detection Limits of Lateral Flow Immunoassays
Zherdev, A. V., & Dzantiev, B. B. (2018) · InTech eBooks · doi:10.5772/intechopen.76926 · Cited by 32
A Bottom-Up Approach for Developing Aptasensors for Abused Drugs: Biosensors in Forensics
Celikbas, E., Hanoglu, S. B., Evran, S., Coşkunol, H., & Tımur, S. (2019) · Biosensors · doi:10.3390/bios9040118 · Cited by 33
Multiplex Immunoassay Techniques for On-Site Detection of Security Sensitive Toxins
Pöhlmann, C., & Elßner, T. (2020) · Toxins · doi:10.3390/toxins12110727 · Cited by 32
Nanopaper Biosensors at Point of Care
Kumar, P., Sarkar, N., Singh, A., & Kaushik, M. (2022) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.2c00213 · Cited by 32
Yeast dual-affinity biobricks: Progress towards renewable whole-cell biosensors
Venkatesh, A. G., Sun, A. C., Brickner, H., Looney, D. J., Hall, D. A., & Aronoff-Spencer, E. S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.044 · Cited by 31
Vashist, S. K., & Luong, J. H. T. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811762-0.00001-3 · Cited by 31
A smartphone biosensor based on analysing structural colour of porous silicon
Cao, T., Zhao, Y., Nattoo, C. A., Layouni, R., & Weiss, S. M. (2019) · The Analyst · doi:10.1039/c9an00022d · Cited by 31
Jindal, G., & Kaur, N. (2022) · Inorganic Chemistry Communications · doi:10.1016/j.inoche.2022.109481 · Cited by 31
Nelis, J. L. D., Bose, U., Broadbent, J. A., Hughes, J. M., Sikes, A. L., Anderson, A. R., Caron, K., Schmoelzl, S., & Colgrave, M. L. (2022) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12935 · Cited by 31
Advancements in nanobiosensor technologies for in-vitro diagnostics to point of care testing
Kim, C., Kang, M. S., Raja, I. S., Joung, Y. K., & Han, D. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e40306 · Cited by 32
Chemical Sensors and Biosensors in Italy: A Review of the 2015 Literature
Compagnone, D., Francia, G. D., Natale, C. D., Neri, G., Seeber, R., & Tajani, A. (2017) · Sensors · doi:10.3390/s17040868 · Cited by 30
Schramm, S., Navizet, I., Naumov, P., Nath, N. K., Berraud‐Pache, R., Oesau, P., Weiss, D. G., & Beckert, R. (2016) · European Journal of Organic Chemistry · doi:10.1002/ejoc.201501515 · Cited by 29
Bio-sensing of metal ions by a novel 3D-printable smartphone spectrometer
Schäfer, M., Bräuler, V., & Ulber, R. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.207 · Cited by 29
Taron, W., Phooplub, K., Sanchimplee, S., Piyanamvanich, K., Jamnongkan, W., Techasen, A., Phetcharaburanin, J., Klanrit, P., Namwat, N., Khuntikeo, N., et al. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130705 · Cited by 29
Nardo, F. D., Anfossi, L., Ozella, L., Saccani, A., Giovannoli, C., Spano, G., & Baggiani, C. (2016) · Journal of Chromatography B · doi:10.1016/j.jchromb.2016.06.019 · Cited by 29
Self-citationFairooz, T., McNamee, S. E., Finlay, D., Ng, K. Y., & McLaughlin, J. A. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.115016 · Cited by 27
Portable Multiplex Optical Assays
Coskun, A. F., Topkaya, S. N., Yetisen, A. K., & Çetin, A. E. (2018) · Advanced Optical Materials · doi:10.1002/adom.201801109 · Cited by 29
Functionalized Advanced Hybrid Materials for Biosensing Applications
Hosu, O., Florea, A., Cristea, C., & Săndulescu, R. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815743-5.00006-8 · Cited by 28
Metadata
- Authors
- Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A.
- Affiliations
- University of Bologna (IT)
- University of Turin (IT)
- Corresponding author
- Roda, Aldo
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 64
- Pages
- 63-68
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2080173526
- Cited by
- 373
- References
- 35
- Citations by year
- 2026: 10 · 2025: 26 · 2024: 27 · 2023: 23 · 2022: 30 · 2021: 37 · 2020: 38 · 2019: 42 · 2018: 44 · 2017: 32 · 2016: 41 · 2015: 23
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Institutional Research Information System University of Turin (University of Turin) (submittedVersion, other-oa)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- salivary cortisol, chemiluminescence, lateral flow immunoassay, smartphone biosensors, luminol, competitive immunoassay
- MeSH terms
- Equipment Design, Humans, Hydrocortisone, Immunoassay, Luminescent Measurements, Saliva, Biosensing Techniques, Point-of-Care Systems, Cell Phone, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review