Development of ultra-low volume, multi-bio fluid, cortisol sensing platform
Open accessAbstract
The development of a non-faradaic electrochemical sensor for screening across multiple bio-fluids that demonstrate the expression of cortisol using a gold microelectrode-based sensor is reported in this paper. Room temperature ionic liquid (RTIL), BMIM[BF 4 ] was used as the buffer to modulate the electrical double layer (EDL) to enhance the electrochemical signal response of the sensor. The sensor design and the surface chemistry was optimized using COMSOL Multiphysics software simulations and FTIR respectively. The sensor was designed so that it uses ultra-low volumes between 3–5 µL of bio-fluid for detection. Cortisol detection was achieved in the physiologically relevant ranges when tested in serum, blood, sweat, and, saliva using non-faradaic Electrochemical Impedance Spectroscopy (EIS) and performance parameters of the sensor were determined. Sensor’s response was tested against the only commercially available salivary cortisol point-of-care kit using regression analysis. Cross-reactive studies using prednisone indicated that the sensor is specific for cortisol. The sensor displayed a correlation value i.e. R 2 > 0.95 between the signal response and the concentration of cortisol present in the system. Dynamic range of the sensor was across the physiologically relevant range of cortisol i.e. 50–200 ng/ml for serum/blood, 1–40 ng/ml for saliva, and 10–150 ng/ml for sweat. Limit of detection for serum and sweat was 10 ng/ml and 1 ng/ml for saliva.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There is a strong empirical correlation between serum and sweat cortisol.
“Since there is a strong empirical correlation between serum and sweat cortisol”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [37]
Exciting opportunities are offered for non-invasive dynamic stress monitoring.
“exciting opportunities are offered for non‐invasive dynamic stress monitoring.[ 8 , 37 ]”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [37]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862 · see citing works
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603 · see citing works
Stress Hormone Regulation: Biological Role and Translation into Therapy
Holsboer, F., & Ising, M. (2010) · Annual Review of Psychology · doi:10.1146/annurev.psych.093008.100321 · Cited by 473 · see citing works
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373 · see citing works
Salivary cortisol reflects serum cortisol: analysis of circadian profiles.
Dorn, L. D., Lucke, J. F., Loucks, T. L., & Berga, S. L. (2007) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456307780480954 · Cited by 228 · see citing works
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179 · see citing works
Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-02133-0 · Cited by 149 · see citing works
Self-citationJagannath, B., Muthukumar, S., & Prasad, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.02.013 · Cited by 56 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
ZnO Nanorod Integrated Flexible Carbon Fibers for Sweat Cortisol Detection
Madhu, S., Anthuuvan, A. J., Ramasamy, S., Manickam, P., Bhansali, S., Nagamony, P., & Chinnuswamy, V. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.9b00730 · Cited by 102 · see citing works
CortiWatch: Watch-Based Cortisol Tracker
Rice, P., Upasham, S., Jagannath, B., Manuel, R., Pali, M., & Prasad, S. (2019) · Future Science OA · doi:10.2144/fsoa-2019-0061 · Cited by 63 · see citing works
Self-citationShajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55 · see citing works
- Authors
- Upasham, S., Tanak, A., Jagannath, B., & Prasad, S.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Prasad, Shalini
- Venue
- Scientific Reports
- Published
- 2018-11-13
- Volume
- 8
- Issue
- 1
- Pages
- 16745-16745
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6233171
- OpenAlex
- W2900178162
- Cited by
- 50
- References
- 8
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 4 · 2021: 8 · 2020: 9 · 2019: 4
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- gold microelectrodes, room temperature ionic liquids, 1-butyl-3-methylimidazolium tetrafluoroborate, electric double layer, electrochemical impedance spectroscopy, salivary cortisol, serum cortisol, blood cortisol, point-of-care testing, sensor simulation
- MeSH terms
- Body Fluids, Calibration, Electrochemistry, Electrodes, Humans, Hydrocortisone, Viscosity, Reproducibility of Results, Biosensing Techniques, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review