The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Automatic smartphone-based microfluidic biosensor system at the point of care
Abstract
Point-of-care testing technique is increasingly important for healthcare management in human being's daily life. However, traditional biosensor systems for health care are relatively expensive, bulky and hard-to-handle, which largely limits their use in point of care testing. The problems mentioned above are successfully addressed with the popularization of smartphone and the development of microfluidic technology for their applications of biosensor, which integrates smartphones, microfluidic components and sensory elements together, paving the way for wide application of smartphone-based microfluidic biomedical sensory system. According to the varieties of analytes, the most common sensing modalities of biosensor systems are divided into imaging analysis to detect cells and bacteria, biochemical analysis to detect blood sugar and blood fat, immunoassay to detect protein specifically bound to antibody, as well as molecular diagnosis to detect DNA and other biomolecules. Based on the most common analytical methods, this review article covers five types of smartphone-based microfluidic biosensor systems at the point-of-care detection, i.e., smartphone-based imaging biosensor, smartphone-based biochemical sensor, smartphone-based immune biosensor, smartphone-based hybrid biosensor with more than one sensing modality, and smartphone-based molecular sensor. We lay emphasis on reviewing the structures, analytical methods and sensing modalities about the four kinds of biosensor systems with detailed discussions on their application potentials, aiming at giving the audience an overview of the recent developments of automatic smartphone-based microfluidic biosensor systems, as well as their future prospective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Interpretation of the Response of Surface Plasmon Resonance Sensors to Adsorbed Films
Jung, L. S., Campbell, C. T., Chinowsky, T. M., Mar, M. N., & Yee, S. S. (1998) · Langmuir · doi:10.1021/la971228b · Cited by 1,012
Optofluidic microsystems for chemical and biological analysis
Fan, X., & White, I. M. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.206 · Cited by 876
Electronic noses for food quality: A review
Loutfi, A., Coradeschi, S., Mani, G. K., Shankar, P., & Rayappan, J. B. B. (2015) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2014.07.019 · Cited by 741
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Better Tests, Better Care: Improved Diagnostics for Infectious Diseases
Caliendo, A. M., Gilbert, D. N., Ginocchio, C. C., Hanson, K. E., May, L., Quinn, T. C., Tenover, F. C., Alland, D., Blaschke, A. J., Bonomo, R. A., et al. (2013) · Clinical Infectious Diseases · doi:10.1093/cid/cit578 · Cited by 628
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
A smartphone dongle for diagnosis of infectious diseases at the point of care
Laksanasopin, T., Guo, T. W., Nayak, S., Sridhara, A. A., Xie, S., Olowookere, O. O., Cadinu, P., Meng, F., Chee, N. H., Kim, J., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa0056 · Cited by 425
Analytical methods for inorganic arsenic in water: a review
Hung, D. Q., Nekrassova, O., & Compton, R. G. (2004) · Talanta · doi:10.1016/j.talanta.2004.01.027 · Cited by 396
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics
Sharma, S., Zapatero-Rodríguez, J., Estrela, P., & O'Kennedy, R. (2015) · Biosensors · doi:10.3390/bios5030577 · Cited by 349
Smartphone-Based Food Diagnostic Technologies: A Review
Rateni, G., Dario, P., & Cavallo, F. (2017) · Sensors · doi:10.3390/s17061453 · Cited by 333
A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses
Priye, A., Bird, S. W., Light, Y. K., Ball, C. S., Negrete, O. A., & Meagher, R. J. (2017) · Scientific Reports · doi:10.1038/srep44778 · Cited by 300
Cholesterol testing on a smartphone
Oncescu, V., Mancuso, M., & Erickson, D. (2014) · Lab Chip · doi:10.1039/c3lc51194d · Cited by 279
Point-of-care quantification of blood-borne filarial parasites with a mobile phone microscope
D’Ambrosio, M. V., Bakalar, M., Bennuru, S., Reber, C., Skandarajah, A., Nilsson, L., Switz, N., Kamgno, J., Pion, S., Boussinesq, M., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3480 · Cited by 237
Barbosa, A. I., Gehlot, P., Sidapra, K., Edwards, A. D., & Reis, N. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.006 · Cited by 225
Smart cup: A minimally-instrumented, smartphone-based point-of-care molecular diagnostic device
Liao, S.-C., Peng, J., Mauk, M. G., Awasthi, S., Song, J., Friedman, H., Bau, H. H., & Liu, C. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.01.073 · Cited by 177
Shi, S., Wang, L., Su, R., Liu, B., Huang, R., Qi, W., & He, Z. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.080 · Cited by 174
Imaging and Sizing of Single DNA Molecules on a Mobile Phone
Wei, Q., Luo, W., Chiang, S., Kappel, T., Mejia, C., Tseng, D., Chan, R. Y. L., Yan, E., Qi, H., Shabbir, F., et al. (2014) · ACS Nano · doi:10.1021/nn505821y · Cited by 169
Uric Acid Monitoring with a Smartphone as the Electrochemical Analyzer
Guo, J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04345 · Cited by 166
Self-citationJi, D., Liu, L., Li, S., Chen, C., Lu, Y., Wu, J., & Liu, Q. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.027 · Cited by 152
Detection of Antibodies in Blood Plasma Using Bioluminescent Sensor Proteins and a Smartphone
Arts, R., den Hartog, I., Zijlema, S. E., Thijssen, V., van der Beelen, S. H. E., & Merkx, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00534 · Cited by 139
Smartphone-Powered Electrochemical Dongle for Point-of-Care Monitoring of Blood β-Ketone
Guo, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02531 · Cited by 129
Self-citationLateral Flow Immunoassays – from Paper Strip to Smartphone Technology
Eltzov, E., Guttel, S., Kei, A. L. Y., Sinawang, P. D., Ionescu, R. E., & Marks, R. S. (2015) · Electroanalysis · doi:10.1002/elan.201500237 · Cited by 127
Smartphone-interfaced 3D printed toxicity biosensor integrating bioluminescent “sentinel cells”
Cevenini, L., Calabretta, M. M., Tarantino, G., Michelini, E., & Roda, A. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.11.017 · Cited by 119
Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels
Guo, J., & Ma, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.026 · Cited by 118
Self-citationSmartphone based bacterial detection using biofunctionalized fluorescent nanoparticles
Rajendran, V. K., Bakthavathsalam, P., & Ali, B. M. J. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1242-5 · Cited by 112
Solar thermal polymerase chain reaction for smartphone-assisted molecular diagnostics
Jiang, L., Mancuso, M., Lu, Z., Akar, G., Cesarman, E., & Erickson, D. (2014) · Scientific Reports · doi:10.1038/srep04137 · Cited by 110
Laboratory Diagnosis of Malaria: Conventional and Rapid Diagnostic Methods
Wilson, M. L. (2013) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2011-0602-ra · Cited by 100
Zhao, H., Qu, Y., Yuan, F., & Quan, X. (2016) · Analytical Methods · doi:10.1039/c5ay03296b · Cited by 77
Huang, X., Guo, J., Wang, X., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104539 · Cited by 68
Self-citationAn optical glucose biosensor based on derived glucose oxidase immobilised onto a sol–gel matrix
de Marcos, S., Galindo, J., Sierra, J. F., Galbán, J., & Castillo, J. R. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00083-0 · Cited by 61
Passive and wireless near field communication tag sensors for biochemical sensing with smartphone
Xu, G., Zhang, Q., Lu, Y.-L., Liu, L., Ji, D., Li, S., & Liu, Q.-J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.149 · Cited by 61
Seo, S.-M., Kim, S., Jeon, J.-W., Kim, J., Kim, H.-S., Cho, J., Lee, W., & Paek, S. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.061 · Cited by 60
Bogoch, I. I., Koydemir, H. C., Tseng, D. K., Ephraim, R. K. D., Duah, E., Tee, J., Andrews, J. R., & Özcan, A. (2017) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.16-0912 · Cited by 59
Enhanced Photoelectrocatalytic Reduction of Oxygen Using Au@TiO2 Plasmonic Film
Guo, L., Liang, K., Marcus, K., Li, Z., Zhou, L., Mani, P. D., Chen, H., Shen, C., Dong, Y., Zhai, L., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b14586 · Cited by 58
An acoustic wave sensor incorporated with a microfluidic chip for analyzing muscle cell contraction
Li, P. C. H., Wang, W., & Parameswaran, M. A. (2003) · The Analyst · doi:10.1039/b209030a · Cited by 47
Fang, J., Qiu, X., Wan, Z., Zou, Q., Su, K., Hu, N., & Wang, P. (2016) · Analytical Methods · doi:10.1039/c6ay01384h · Cited by 44
Guo, J., Lei, W., Ma, X., Xue, P., Chen, Y., & Kang, Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2275091 · Cited by 36
Self-citationBélec, L., & Bonn, J. (2011) · Future Microbiology · doi:10.2217/fmb.11.121 · Cited by 36
Novel optical solid-state glucose sensor using immobilized glucose oxidase
Johnson, B. J., & Harmon, H. J. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)02051-x · Cited by 35
Kim, S., Cho, I., Lim, G.-S., Park, G.-N., & Paek, S. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.032 · Cited by 34
A Microfluidic Impedance Cytometer on Printed Circuit Board for Low Cost Diagnosis
Guo, J., Li, H., Chen, Y., et al. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2295399 · Cited by 29
Self-citationMedically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System
Wargocki, P. M., Deng, W., Anwer, A. G., & Goldys, E. M. (2015) · Sensors · doi:10.3390/s150511653 · Cited by 29
Isolation and elution of Hep3B circulating tumor cells using a dual-functional herringbone chip
Xue, P., Ye, K., Gao, J., Wu, Y., Guo, J., Hui, K. M., & Kang, Y. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1250-5 · Cited by 18
Self-citation
Cited by
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Diagnostic methods and potential portable biosensors for coronavirus disease 2019
Cui, F., & Zhou, H. S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112349 · Cited by 373
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 335
A study on medical Internet of Things and Big Data in personalized healthcare system
Jagadeeswari, V., Subramaniyaswamy, V., Logesh, R., & Vijayakumar, V. (2018) · Health Information Science and Systems · doi:10.1007/s13755-018-0049-x · Cited by 321
Metadata
- Authors
- Xu, D., Huang, X., Guo, J., & Ma, X.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 110
- Pages
- 78-88
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2791328049
- Cited by
- 264
- References
- 47
- FWCI
- 14.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.