Highly self-healable and flexible cable-type pH sensors for real-time monitoring of human fluids
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Development of sensing technology with wearable chemical sensors is realizing non-invasive, real-time monitoring healthcare and disease diagnostics. The advanced sensor devices should be compact and portable for use in limited space, easy to wear on human body, and low-cost for personalized healthcare markets. Here, we report a highly sensitive, flexible, and autonomously self-healable pH sensor cable developed by weaving together two carbon fiber thread electrodes coated with mechanically robust self-healing polymers. The pH sensor cable showed excellent electrochemical performances of sensitivity, repeatability, and durability. Spontaneous and autonomous sensor healing efficiency of the pH sensor cable was demonstrated by measuring sensitivity during four cycles of cutting and healing process. The pH sensor cable could measure pH in small volumes of real human fluid samples, including urine, saliva, and sweat, and the results were similar to those of a commercial pH meter. Taken together, successful real-time pH monitoring for human sweat was demonstrated by fabricating a wearable sensing system in which the pH sensor cable was knitted into a headband integrated with wireless electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Stretchable wireless system for sweat pH monitoring
Dang, W., Manjakkal, L., Navaraj, W. T., Lorenzelli, L., Vinciguerra, V., & Dahiya, R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.025 · Cited by 326
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269
Cited by
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Cho, S., Hwang, S. Y., Oh, D. X., & Park, J. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta02308j · Cited by 482
Self-citationProgress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237
Self‐Healing Soft Sensors: From Material Design to Implementation
Khatib, M., Zohar, O., & Haick, H. (2021) · Advanced Materials · doi:10.1002/adma.202004190 · Cited by 219
Metadata
- Authors
- Yoon, J. H., Kim, S.-M., Park, H. J., Kim, Y. K., Oh, D. X., Cho, H.-W., Lee, K. G., Hwang, S. Y., Park, J., & Choi, B. G.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 150
- Pages
- 111946
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2993650165
- Cited by
- 120
- References
- 9
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly self-healable and flexible cable-type pH sensors for real-time monitoring of human fluids. https://app.cochat.ai/papers/10.1016/j.bios.2019.111946
- The paper
- Yoon, J. H., Kim, S.-M., Park, H. J., Kim, Y. K., Oh, D. X., Cho, H.-W., Lee, K. G., Hwang, S. Y., Park, J., & Choi, B. G. (2020). Highly self-healable and flexible cable-type pH sensors for real-time monitoring of human fluids. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.111946
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.